共 11 条
Winding condition monitoring for inverter-fed PMSM using high-frequency current injection
被引:0
作者:
Xu, Zheng
[1
]
Zhang, Jianzhong
[1
]
Zhang, Yaqian
[1
]
Zhao, Jin
[1
]
机构:
[1] Southeast Univ, Sch Elect Engn, Nanjing 210096, Peoples R China
来源:
2020 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE)
|
2020年
关键词:
High frequency current injection;
PMSM;
inter-turn short-circuit fault;
FAULT-DIAGNOSIS;
MACHINES;
D O I:
暂无
中图分类号:
TE [石油、天然气工业];
TK [能源与动力工程];
学科分类号:
0807 ;
0820 ;
摘要:
This paper proposes a winding condition monitoring scheme for inverter-fed permanent magnet synchronous machines (PMSM) based on high frequency (HF) current injection. With the introduction of specific HF current regulator, HF current can be injected into two phases of the stator windings. And the corresponding HF component of the line control voltage between the two phases is extracted to determine whether there is an inter-turn short-circuit fault. After monitoring different winding pairs alternately, inter-turn short fault can be detected and the faulty phase can be located. The proposed method has high sensitivity to the inter-turn short fault and is able to eliminate the effect of working conditions. The effectiveness of the proposed method is validated by simulations.
引用
收藏
页码:777 / 782
页数:6
相关论文