Experimental Study of Interior Glass Fiber-Reinforced Polymer-Reinforced Concrete Slab-Column Connections under Lateral Cyclic Load

被引:19
作者
Eladawy, Mohamed [1 ]
Hassan, Mohamed [1 ,2 ]
Benmokrane, Brahim [3 ,4 ,5 ]
机构
[1] Univ Sherbrooke, Dept Civil Engn, Sherbrooke, PQ, Canada
[2] Queens Univ, Dept Civil Engn, Kingston, ON, Canada
[3] Univ Sherbrooke, Dept Civil Engn, Civil Engn, Sherbrooke, PQ, Canada
[4] Univ Sherbrooke, Dept Civil Engn, FRP Reinforcement Concrete Infrastruct, Sherbrooke, PQ, Canada
[5] Univ Sherbrooke, Dept Civil Engn, Adv Composite Mat Civil Struct, Sherbrooke, PQ, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
cyclic loading; design codes; dissipated energy; drift capacity; ductility; glass fiber-reinforced polymer bars; punching shear; reinforced concrete slab-column connection; PUNCHING SHEAR BEHAVIOR; SEISMIC BEHAVIOR;
D O I
10.14359/51716803
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The feasibility of using fiber-reinforved polymers (PRPs) as internal reinforcement for a totally reinforced concrete (RC) structure immune to corrosion essentially pertains to strength, stiffness, and deformation capacity in resisting seismic loads has become questionable. Nevertheless, no experiments have yet been conducted on the punching-shear behavior of FRP-reinforced concrete (FRP-RC) slab-column connections subjected to lateral reversal cyclic loading. Consequently, current FRP-RC design guidelines and codes in North America contain no seismic provisions. This has been the main impetus to conduct the ,first-ever experimental study on the punching shear behavior of glass-FRP (GFRP) slab-column connections under the combination of gravity and lateral reversed cyclic loading. Four full-scale interior slab-column connections were constructed and tested to investigate the influence of flexural-reinforrement type (GFRP and steel bars), reinforcement ratio, and gravity load intensity on the punching shear performance. All test specimens were identical and measured 2500 x 2500 mm with a thickness of 200 mm. A column measuring 300 x 300 mm extended 700 mm at its center above and below the slab surfaces. The results revealed that the GFRP-RC specimens possessed adequate strength and deformation capacity against punching-shear failure during and after reserved lateral cyclic-load conditions. The GFRP-RC specimens achieved lateral interstory drift capacities over 1.50% satisfying the limits in CSA A23.3 and ACI 421.3R. The GFRP-RC specimens also had adequate drift-ductility indexes, dissipated energy, and connection stiffness. Moreover; the GFRP bar strains at the ultimate lateral-drift ratio were less than the guaranteed tensile strength by 42%. No rupture of the GFRP bars and bond failure or slip were observed during the test.
引用
收藏
页码:165 / 180
页数:16
相关论文
共 32 条
[1]   Seismic Performance of GFRP-Reinforced Concrete Rectangular Columns [J].
Ali, Mahmoud A. ;
El-Salakawy, Ehab .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2016, 20 (03)
[2]  
[Anonymous], 2010, 4212R10 ACI
[3]  
[Anonymous], 2004, ACI Committee 440.
[4]  
[Anonymous], D7205M ASTM
[5]  
[Anonymous], 2014, Building Code Requirements for Structural Concrete (ACI 318-14) and Commentary (ACI 318R-14). ACI 318-14
[6]  
[Anonymous], 2015, American Concrete Institute (ACI) Committee 440.
[7]  
[Anonymous], 2014, S614 CANCSA
[8]  
[Anonymous], S80715 CANCSA
[9]  
CAN, 2012, CAN/CSA S806-12
[10]  
CanadianStandardsAssociation(CSA), 2014, CSA-A23.3 M-14