Converging flow chromatography in constant-pressure mode

被引:4
作者
Pfeiffer, W [1 ]
机构
[1] Serv Tech, D-19322 Wittenberge, Germany
关键词
converging flow chromatography; radial flow chromatography; axial flow chromatography; instrumentation; column geometry; pressure control;
D O I
10.1016/S0021-9673(03)00780-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Dispersion in chromatographic processes can be reduced to a minimum using converging columns and a curved frit at the outlet. Working at constant pressure at the inlet the internal packing is increasingly compressed by the accelerated flow. Thus the packed bed is stabilized. Under these conditions the observed flux at the outlet and the power input of the pump are inversely related to the viscosity of the eluting solute. Comparing converging flow chromatography (CFC) with classical axial flow chromatography (AFC) and radial flow chromatography (RFC) the stationary phase is used more efficiently in CFC. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:149 / 170
页数:22
相关论文
共 74 条
[1]  
*AM, APPL BROCH SEPH G 25
[2]  
BAER J, 1972, DYNAMICS FLUIDS PORO, P127
[3]   Temperature gradients in preparative high-performance liquid chromatography columns [J].
Brandt, A ;
Mann, G ;
Arlt, W .
JOURNAL OF CHROMATOGRAPHY A, 1997, 769 (01) :109-117
[4]   CONICAL PREPARATIVE THIN-LAYER CHROMTOGRAPHY [J].
BRENDEL, K ;
STEELE, RS ;
DAVIDSON, EA .
JOURNAL OF CHROMATOGRAPHY, 1967, 30 (01) :232-&
[5]  
Carman P. C., 1937, T I CHEM ENG-LOND, V15, P150, DOI [10.1016/S0263-8762(97)80003-2, DOI 10.1016/S0263-8762(97)80003-2]
[6]   FILM FORMATION WITH LATEX-PARTICLES [J].
CHEVALIER, Y ;
PICHOT, C ;
GRAILLAT, C ;
JOANICOT, M ;
WONG, K ;
MAQUET, J ;
LINDNER, P ;
CABANE, B .
COLLOID AND POLYMER SCIENCE, 1992, 270 (08) :806-821
[7]   Flow of non-Newtonian fluids in fixed and fluidised beds [J].
Chhabra, RP ;
Comiti, J ;
Machac, I .
CHEMICAL ENGINEERING SCIENCE, 2001, 56 (01) :1-27
[8]   Experimental characterization of flow regimes in various porous media - III: limit of Darcy's or creeping flow regime for Newtonian and purely viscous non-Newtonian fluids [J].
Comiti, J ;
Sabiri, NE ;
Montillet, A .
CHEMICAL ENGINEERING SCIENCE, 2000, 55 (15) :3057-3061
[9]   Size-exclusion chromatography on soft packing material under axial compression [J].
Danilov, AV ;
Mustaeva, LG ;
Vagenina, IV ;
Baru, MB .
JOURNAL OF CHROMATOGRAPHY A, 1996, 732 (01) :17-25
[10]   Effect of radial gradient of temperature on the performance of large-diameter high-performance liquid chromatography columns I. Analytical conditions [J].
Dapremont, O ;
Cox, GB ;
Martin, M ;
Hilaireau, P ;
Colin, H .
JOURNAL OF CHROMATOGRAPHY A, 1998, 796 (01) :81-99