Response of Ventricular Repolarization Parameters to Preload Changes in the Isolated Working Heart

被引:0
作者
Hejc, Jakub [1 ]
Janousek, Oto [1 ]
Ronzhina, Marina [1 ]
Stracina, Tibor [2 ]
Olejnickova, Veronika [2 ]
Kolarova, Jana [1 ]
Novakova, Marie [2 ,3 ]
机构
[1] Brno Univ Technol, Brno, Czech Republic
[2] Masaryk Univ, Brno, Czech Republic
[3] Int Clin Res Ctr, Brno, Czech Republic
来源
2016 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 43 | 2016年 / 43卷
关键词
QT;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Heart rate dependency of ventricular repolarization (VR) parameters has been a well known phenomenon for many years. Other contributing factors, such as Mechano-electric Coupling, are still under investigation. In this work, we analyze step response of VR parameters after abrupt change in mechanical end-diastolic load. 10 isolated rabbit hearts were perfused in Working Heart mode. The protocol consisted of abrupt changes in preload level of 3 cmH(2)O. Left ventricle electric activity was recorded by seven unipolar leads at sampling frequency 10 kHz. A second-order transfer function model was used to identify basic parameters of QT(END) and QT(PEAK) step responses, detected in reconstructed global pseudo-lead. Results show inverse relationship between changes in the preload and the length of QT related intervals. Increase of the preload causes significant (p<0.05) shortening of both intervals within the range of 1.6-26.9 ms. On the contrary, preload decreasing leads to prolongation of repolarization parameters, however, with significantly lower (p<0.05) average magnitude. Dynamic response is highly individual among each heart. Average time needed to reach stable QT in our data is 336.0 seconds, while min. and max. value is 41.4 and 894.0 seconds, respectively.
引用
收藏
页码:409 / 412
页数:4
相关论文
共 7 条
[1]  
Halámek J, 2010, COMPUT CARDIOL CONF, V37, P365
[2]   A Wavelet-Based ECG Delineation Method: Adaptation to an Experimental Electrograms with Manifested Global Ischemia [J].
Hejc, Jakub ;
Vitek, Martin ;
Ronzhina, Marina ;
Novakova, Marie ;
Kolarova, Jana .
CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2015, 6 (03) :364-375
[3]   Experimental Methods for Simultaneous Measurement of Action Potentials and Electrograms in Isolated Heart [J].
Kolarova, J. ;
Fialova, K. ;
Janousek, O. ;
Novakova, M. ;
Provaznik, I. .
PHYSIOLOGICAL RESEARCH, 2010, 59 :S71-S80
[4]   HYSTERESIS OF THE VENTRICULAR PACED QT INTERVAL IN RESPONSE TO ABRUPT CHANGES IN PACING RATE [J].
LAU, CP ;
FREEDMAN, AR ;
FLEMING, S ;
MALIK, M ;
CAMM, AJ ;
WARD, DE .
CARDIOVASCULAR RESEARCH, 1988, 22 (01) :67-72
[5]   Subject-specific heart rate dependency of electrocardiographic QT, PQ, and QRS intervals [J].
Malik, Marek ;
Hnatkova, Katerina ;
Sisakova, Martina ;
Schmidt, Georg .
JOURNAL OF ELECTROCARDIOLOGY, 2008, 41 (06) :491-497
[6]   The importance of non-uniformities in mechano-electric coupling for ventricular arrhythmias [J].
Quinn, T. Alexander .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2014, 39 (01) :25-35
[7]  
Zabel M, 1996, CARDIOVASC RES, V32, P120, DOI 10.1016/0008-6363(96)00089-2