Multivariate data analysis of dynamic amperometric biosensor responses from binary analyte mixtures -: application of sensitivity correction algorithms

被引:12
作者
Dock, E
Christensen, J
Olsson, M
Tonning, E
Ruzgas, T
Emnéus, J
机构
[1] Lund Univ, Dept Analyt Chem, SE-22100 Lund, Sweden
[2] Royal Vet & Agr Univ, Dept Dairy & Food Sci, Chemometr Grp, DK-1958 Frederiksberg C, Denmark
关键词
flow injection; biosensors; chemometrics; phenols; amperometry; drift correction;
D O I
10.1016/j.talanta.2004.07.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, it is demonstrated that a single-receptor biosensor can be used to quantitatively determine each analyte in binary Mixtures LIS in multivariate data analysis tools based on the dynamic responses received from flow injection peaks. Mixtures with different concentrations of two phenolic compounds, catechol and 4-chlorophenol, were measured with a graphite electrode modified with tyrosinase enzyme at an applied potential of -50 mV versus Ag/AgCl. A correction algorithm based on measurements of references in-between samples was applied to compensate for biosensor ageing as well as differences caused by deviations between biosensor preparations. After correction, the relative prediction errors with partial least squares regression (PLS-R) for catechol and 4-chlorophenol were 7.4 and 5.5%, respectively, using an analysis sequence measured on one biosensor. Additional validation mixtures of the two phenols were measured with a new biosensor, prepared with the same procedure but with a different batch of tyrosinase enzyme. Using the mixture responses for the first sensor as a calibration set in PLS-R. the relative prediction errors of the validation mixtures, after applying correction procedures. were 7.0% for catechol and 16.0% for 4-chlorophenol. These preliminary results indicate that by applying correction algorithms it could be possible to use less stable biosensors in continuous on-line measurements together with multivariate data analysis without time-consuming calibration procedures. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:298 / 305
页数:8
相关论文
共 35 条
[1]   Cross-reactive chemical sensor arrays [J].
Albert, KJ ;
Lewis, NS ;
Schauer, CL ;
Sotzing, GA ;
Stitzel, SE ;
Vaid, TP ;
Walt, DR .
CHEMICAL REVIEWS, 2000, 100 (07) :2595-2626
[2]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[3]   ENZYMATIC DETERMINATION OF GLUCOSE IN A FLOW SYSTEM BY CATALYTIC-OXIDATION OF THE NICOTINAMIDE COENZYME AT A MODIFIED ELECTRODE [J].
APPELQVIST, R ;
MARKOVARGA, G ;
GORTON, L ;
TORSTENSSON, A ;
JOHANSSON, G .
ANALYTICA CHIMICA ACTA, 1985, 169 (MAR) :237-247
[4]  
Artursson T, 2000, J CHEMOMETR, V14, P711, DOI 10.1002/1099-128X(200009/12)14:5/6<711::AID-CEM607>3.3.CO
[5]  
2-W
[6]   A disposable multielectrode biosensor for rapid simultaneous detection of the insecticides paraoxon and carbofuran at high resolution [J].
Bachmann, TT ;
Schmid, RD .
ANALYTICA CHIMICA ACTA, 1999, 401 (1-2) :95-103
[7]   Improved multianalyte detection of organophosphates and carbamates with disposable multielectrode biosensors using recombinant mutants of Drosophila acetylcholinesterase and artificial neural networks [J].
Bachmann, TT ;
Leca, B ;
Vilatte, F ;
Marty, JL ;
Fournier, D ;
Schmid, RD .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (3-4) :193-201
[8]   Effect of interfering substances on current response of recombinant peroxidase and glucose oxidase- recombinant peroxidase modified graphite electrodes [J].
Dock, E ;
Lindgren, A ;
Ruzgas, T ;
Gorton, L .
ANALYST, 2001, 126 (11) :1929-1935
[9]   Rapid identification of viable Escherichia coli subspecies with an electrochemical screen-printed biosensor array [J].
Ertl, P ;
Wagner, M ;
Corton, E ;
Mikkelsen, SR .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (07) :907-916
[10]   Electrochemical biosensor array for the identification of microorganisms based on lectin-lipopolysaccharide recognition [J].
Ertl, P ;
Mikkelsen, SR .
ANALYTICAL CHEMISTRY, 2001, 73 (17) :4241-4248