A comparison of adult pulmonary autograft diameter measurements with echocardiography and magnetic resonance imaging

被引:3
|
作者
Hokken, RB
de Bruin, HG
Taams, MA
Schiks-Berghout, M
Steyerberg, EW
Bogers, AJJC
van Herwerden, LA
Oudkerk, M
Roelandt, JRTC
Bos, E
机构
[1] Univ Hosp Dijkzigt, Dept Cardiopulm Surg, NL-3015 GD Rotterdam, Netherlands
[2] Univ Hosp Dijkzigt, Dept Radiol, NL-3015 GD Rotterdam, Netherlands
[3] Univ Hosp Dijkzigt, Dept Cardiol, NL-3015 GD Rotterdam, Netherlands
[4] Erasmus Univ, Dept Publ Hlth, Rotterdam, Netherlands
关键词
pulmonary autograft; aortic valve; magnetic resonance imaging; echocardiography;
D O I
10.1053/euhj.1997.0745
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In 38 consecutive patients the pulmonary autograft was used in aortic root replacement. Investigations were performed with transthoracic echocardiography, transoesophageal echocardiography and magnetic resonance imaging in 31, 27 and 27 patients respectively. The mean age at operation was 28.7 years (range 19.0-52.0) and the follow-up period was 2.8 years (range 0.8-6.7). The pulmonary autograft diameter was measured at the subannular region (1), at the annulus at the hinge points of the valve leaflets (2), at the sinus (3), at the sine-tubular junction (4) and at the distal part of the autograft (5). With transoesophageal echocardiography the mean systolic measurements at levels 1 to 5 were 32, 31, 42, 35 and 34 mm, respectively. The corresponding diastolic measurements were smaller: 25, 28, 42, 35 and 34 mm respectively. There was no significant difference between transthoracic echocardiography and transoesophageal echocardiography measurements of the proximal autograft (levels 1-3). Diameters obtained with magnetic resonance imaging were 1 to 3 mm larger than those obtained with transthoracic echocardiography and transoesophageal echocardiography (P<0.05), except the annulus at systole (P>0.3). Conclusions The mean pulmonary autograft diameters measured using transthoracic echocardiography, transoesophageal echocardiography and magnetic resonance imaging were larger than native aortic and pulmonary diameters of a normal population in the same age group. Diameters of the distal 2 levels could not be imaged reliably with transthoracic echocardiography. Magnetic resonance imaging diameter measurements were, in general, larger than with echocardiography.
引用
收藏
页码:301 / 309
页数:9
相关论文
共 50 条
  • [41] Measurement of left ventricular volume after anterior myocardial infarction: comparison of magnetic resonance imaging, echocardiography, and radionuclide ventriculography
    K.H. Darasz
    S.R. Underwood
    J. Bayliss
    S.M. Forbat
    J. Keegan
    P.A. Poole-Wilson
    G.C. Sutton
    The International Journal of Cardiovascular Imaging, 2002, 18 : 135 - 142
  • [42] Comparison of echocardiography with tissue Doppler imaging and magnetic resonance imaging with delayed enhancement in the assessment of children with hypertrophic cardiomyopathy
    Ziolkowska, Lidia
    Petryka, Joanna
    Boruc, Agnieszka
    Kawalec, Wanda
    ARCHIVES OF MEDICAL SCIENCE, 2017, 13 (02) : 328 - 336
  • [43] An integrated imaging approach with magnetic resonance imaging can reveal pitfall pleural effusion at echocardiography
    Di Bella, Gianluca
    Anfuso, Carmelo
    Carerj, Scipione
    Donato, Rocco
    Zito, Concetta
    Minutoli, Fabio
    Patane, Salvatore
    Coglitore, Sebastiano
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 133 (03) : E99 - E100
  • [44] Pulmonary Atresia with Ventricular Septal Defect without Major Aorto-Pulmonary Collateral Arteries: Echocardiography and the Role of Computed Tomography and Magnetic Resonance Imaging
    Gurson, Sarah Chambers
    WORLD JOURNAL FOR PEDIATRIC AND CONGENITAL HEART SURGERY, 2025, 16 (02) : 183 - 190
  • [45] Post-operative Assessment of the Arterial Switch Operation: A Comparison of Magnetic Resonance Imaging and Echocardiography
    Broda, Christopher R.
    Shugh, Svetlana B.
    Parikh, Rohan B.
    Wang, YunFei
    Schlingmann, Tobias R.
    Noel, Cory V.
    PEDIATRIC CARDIOLOGY, 2018, 39 (05) : 1036 - 1041
  • [46] Post-operative Assessment of the Arterial Switch Operation: A Comparison of Magnetic Resonance Imaging and Echocardiography
    Christopher R. Broda
    Svetlana B. Shugh
    Rohan B. Parikh
    YunFei Wang
    Tobias R. Schlingmann
    Cory V. Noel
    Pediatric Cardiology, 2018, 39 : 1036 - 1041
  • [47] Comparison of Left Ventricular Function and Mass Assessment on Everyday Echocardiography and Cardiac Magnetic Resonance Imaging
    Lee, Mirae
    Byeon, Kyeongmin
    Kim, Eun Young
    Yang, Jeong Hoon
    Lee, Sungho
    Park, Sung Beom
    Chung, Seungmin
    Park, Jeong-Euy
    Choe, Yeon Hyeon
    Lee, Sang-Chol
    CIRCULATION, 2010, 122 (21)
  • [48] Measurement of left ventricular volume after anterior myocardial infarction: comparison of magnetic resonance imaging, echocardiography, and radionuclide ventriculography
    Darasz, KH
    Underwood, SR
    Bayliss, J
    Forbat, SM
    Keegan, J
    Poole-Wilson, PA
    Sutton, GC
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2002, 18 (02): : 135 - 142
  • [49] Giant fibroma in the left ventricle of an infant: imaging findings in magnetic resonance imaging, echocardiography and angiography
    Gutberlet, Matthias
    Abdul-Khaliq, Hashim
    Stiller, Brigitte
    Schubert, Ulf
    Stoltenburg-Didinger, Gisela
    Lange, Peter E.
    Hetzer, Roland
    Felix, Roland
    EUROPEAN RADIOLOGY, 2002, 12 (Suppl 3) : S143 - S148
  • [50] Papillary fibroelastoma of the aortic valve - Evaluation with transesophageal echocardiography and magnetic resonance imaging
    Shiraishi, J
    Tagawa, M
    Yamada, T
    Sawada, T
    Tatsumi, T
    Azuma, A
    Shimada, Y
    Yaku, H
    Kitamura, N
    Nakagawa, M
    JAPANESE HEART JOURNAL, 2003, 44 (05): : 799 - 803