Atomic spectrometric detectors for gas chromatography

被引:24
作者
Li, Chenghui [1 ]
Long, Zhou [2 ]
Jiang, Xiaoming [2 ]
Wu, Peng [2 ]
Hou, Xiandeng [1 ,2 ]
机构
[1] Sichuan Univ, Coll Chem, Chengdu 610064, Sichuan, Peoples R China
[2] Sichuan Univ, Analyt & Testing Ctr, Chengdu 610064, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Atomic absorption spectrometry; Atomic emission spectrometry; Atomic fluorescence spectrometry; Mass spectrometry; Gas chromatography; Element-specific detection; SOLID-PHASE MICROEXTRACTION; PLASMA-MASS SPECTROMETRY; MICROWAVE-INDUCED PLASMA; DIELECTRIC BARRIER DISCHARGE; MOLECULAR-EMISSION SPECTROMETER; LASER ABSORPTION SPECTROMETRY; MERCURY SPECIATION ANALYSIS; SELENO AMINO-ACIDS; GC-ICP-MS; FLUORESCENCE SPECTROMETRY;
D O I
10.1016/j.trac.2015.11.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Various atomic spectrometric detectors have been used in gas chromatography (GC) for widespread analytical applications. Their excellent characteristics including high sensitivity and selectivity, low limits of detection (LODs), and the possibility of simultaneous multi-element detection for metallic and nonmetallic species make them ideal detectors as a unique solution for many analytical problems. Different types of atomic spectrometric detectors coupled to GC, including those based on atomic absorption spectrometry (AAS), atomic fluorescence spectrometry (AFS), plasma atomic emission spectrometry/mass spectrometry (AES/MS), are discussed in this article, primarily in terms of operational characteristics, analytical performance and practical applications. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:139 / 155
页数:17
相关论文
共 144 条
[1]   Comparison of extraction procedures for methylmercury determination by a SPME-GC-AFS system [J].
Abranko, Laszlo ;
Kmellar, Bela ;
Fodor, Peter .
MICROCHEMICAL JOURNAL, 2007, 85 (01) :122-126
[2]   Validation, using a chemometric approach, of gas chromatography-inductively coupled plasma-atomic emission spectrometry (GC-ICP-AES) for organotin determination [J].
Aguerre, S ;
Pécheyran, C ;
Lespes, G .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (02) :226-235
[3]   Speciation of organotins in environmental samples by SPME-GC: comparison of four specific detectors: FPD, PFPD, MIP-AES and ICP-MS [J].
Aguerre, S ;
Lespes, G ;
Desauziers, V ;
Potin-Gautier, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (03) :263-269
[4]   Optimisation of the hyphenation between solid-phase microextraction, capillary gas chromatography and inductively coupled plasma atomic emission spectrometry for the routine speciation of organotin compounds in the environment [J].
Aguerre, S ;
Pécheyran, C ;
Lespes, G ;
Krupp, E ;
Donard, OFX ;
Potin-Gautier, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (12) :1429-1433
[5]   CHEMICAL ALKYLATION OF LEAD (II) SALTS TO TETRAALKYLLEAD (IV) IN AQUEOUS-SOLUTION [J].
AHMAD, I ;
CHAU, YK ;
WONG, PTS ;
CARTY, AJ ;
TAYLOR, L .
NATURE, 1980, 287 (5784) :716-717
[6]   Some unique properties of gas chromatography coupled with atomic-emission detection [J].
Andersson, JT .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (06) :344-355
[7]   DETERMINATION OF ORGANOPHOSPHORUS INSECTICIDE RESIDUES USING EMISSION SPECTROMETRIC DETECTOR [J].
BACHE, CA ;
LISK, DJ .
ANALYTICAL CHEMISTRY, 1965, 37 (12) :1477-&
[9]   A capacitively coupled microplasma (CCμP) formed in a channel in a quartz wafer [J].
Bass, A ;
Chevalier, C ;
Blades, MW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (09) :919-921
[10]   COUPLED GAS-CHROMATOGRAPHY ATOMIC-ABSORPTION SPECTROMETRY USING SEMIENCLOSED TUBULAR ATOMIZERS - THEORETICAL-ANALYSIS OF DETECTOR PERFORMANCE-CHARACTERISTICS [J].
BAXTER, DC ;
FRECH, W .
ANALYST, 1993, 118 (05) :495-504