Impact of different preanalytical conditions on results of lupus anticoagulant tests

被引:6
作者
Kristoffersen, Ann Helen [1 ,2 ]
Hammer, Ida Jansrud [3 ]
Vannes, Solveig [1 ]
Asberg, Arne [4 ]
Aakre, Kristin Moberg [1 ,5 ,6 ]
机构
[1] Haukeland Hosp, Helse Bergen, Dept Med Biochem & Pharmacol, Postbox 1400, N-5021 Bergen, Norway
[2] Haraldsplass Deaconess Hosp, Norwegian Org Qual Improvement Lab Examinat Noklu, Bergen, Norway
[3] Haukeland Hosp, Dept Pediat, Bergen, Norway
[4] Trondheim Reg & Univ Hosp, Dept Clin Chem, Trondheim, Norway
[5] Haukeland Hosp, Helse Bergen, Hormone Lab, Bergen, Norway
[6] Univ Bergen, Dept Clin Sci, Bergen, Norway
关键词
dilute Russell's viper venom time; lupus anticoagulant; preanalytical conditions; silica clotting time; stability; QUALITY STANDARDS; WHOLE-BLOOD; STABILITY; PLASMA; FRESH; TIME; CENTRIFUGATION; GUIDELINES; STORAGE; SAMPLES;
D O I
10.1111/ijlh.13102
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction The currently recommended preanalytical conditions for lupus anticoagulant (LA) analysis require analyzing samples in fresh or freshly frozen platelet-poor plasma. The aim of this study was to evaluate whether alternative and less cumbersome preanalytical procedures for LA testing give significantly different results compared to recommended conditions. Materials and Methods Citrated blood samples were drawn from 29 study participants, 15 with negative and 14 with positive LA results. The samples were processed according to the ISTH guideline for LA testing and compared to several alternative preanalytical conditions. Measurements were performed using the dilute Russell's viper venom time (DRVVT) and silica clotting time (SCT), both screen and confirm, on a STA-R Evolution analyzer. Stability criteria were based upon biological variation. Results All DRVVT tests (normalized screen, confirm, and screen/confirm ratio) met the stability criteria for all the preanalytical conditions. The SCT tests (normalized screen, confirm, and screen/confirm ratio) met the stability criteria only when treated according to the ISTH guideline, except for SCT normalized screen/confirm ratio which also met the stability criteria for double-centrifuged aliquoted plasma stored in room temperature for 24 hours and then analyzed "fresh" or after being frozen. One warfarin-treated patient was reclassified from positive to negative for DRVVT after the preanalytical modifications, while 2 of 29 participants became falsely positive for 2 of 8 conditions for SCT. Conclusions The DRVVT assays met the criteria for stability for all preanalytical conditions tested, while the SCT assays should be interpreted with caution if the preanalytical guidelines from ISTH are not followed.
引用
收藏
页码:745 / 753
页数:9
相关论文
共 30 条
[1]  
[Anonymous], 1992, Fed Regist, V57, P7002
[2]  
Asberg KBS A, 2011, KLIN BIOKEMI NORDEN, V23, P34
[3]   Lupus anticoagulant testing and anticoagulation do not mix: quantitation of discrepant results and potential approaches to reduce false positives [J].
Chandler, Jocelyn B. ;
Torres, Richard ;
Rinder, Henry M. ;
Tormey, Christopher A. .
BRITISH JOURNAL OF HAEMATOLOGY, 2014, 167 (05) :704-707
[4]  
Clinical and Laboratory Standards Institute (CLSI), 2014, CLSI document H60-A
[5]   Dilute Russell's viper venom time reagents in lupus anticoagulant testing: a well-considered choice [J].
Depreter, Barbara ;
Devreese, Katrien M. J. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (01) :91-101
[6]   Antiphospholipid antibody testing for the antiphospholipid syndrome: a comprehensive practical review including a synopsis of challenges and recent guidelines [J].
Favaloro, Emmanuel J. ;
Wong, Richard C. W. .
PATHOLOGY, 2014, 46 (06) :481-495
[7]   Proposals for setting generally applicable quality goals solely based on biology [J].
Fraser, CG ;
Petersen, PH ;
Libeer, JC ;
Ricos, C .
ANNALS OF CLINICAL BIOCHEMISTRY, 1997, 34 :8-12
[8]   Lupus anticoagulant testing: analyzing fresh samples after a single centrifugation and after a 6-8 h delay [J].
Froom, Paul ;
Barak, Mira .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, 50 (02) :367-370
[9]   Testing for lupus anticoagulants - fresh or frozen? [J].
Froom, Paul ;
Barak, Mira .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, 50 (09) :1607-1609
[10]  
Funk D.M., 2008, Collection, transport, and processing of blood specimens for testing plasma-based coagulation assays and molecular hemostasis assays: approved guideline, V5th