Characterization and optimization of images acquired by a compact soft X-ray microscope based on a double stream gas-puff target source

被引:3
作者
Torrisi, A. [1 ]
Wachulak, P. [1 ]
Nawaz, M. Fahad [2 ]
Bartnik, A. [1 ]
Wegrzynski, L. [1 ]
Jancarek, A. [2 ]
Fiedorowicz, H. [1 ]
机构
[1] Mil Univ Technol, Inst Optoelect, Kaliskiego 2 Str, PL-00908 Warsaw, Poland
[2] Czech Tech Univ, Fac Nucl Sci & Phys Engn, Brehova 7, CR-11519 Prague 1, Czech Republic
来源
JOURNAL OF INSTRUMENTATION | 2016年 / 11卷
基金
欧盟第七框架计划;
关键词
Data processing methods; Optics; Inspection with x-rays; Interaction of radiation with matter; SIGNAL-TO-NOISE; NM SPATIAL-RESOLUTION; WATER WINDOW MICROSCOPE; LASER-PLASMA SOURCE; ILLUMINATION; DEPENDENCE; SPERM; RATIO;
D O I
10.1088/1748-0221/11/04/C04003
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Using a table-top size soft X-ray (SXR) microscope, based on a laser plasma source with a double stream gas-puff target and a Fresnel zone plate objective, series of images of test samples were acquired. Characterization and optimization of the acquisition parameters were studied and evaluated in terms of signal to noise ratio (SNR). Conclusions for the optimization of SXR imaging were reached. Similar SNR measurements might be performed to characterize other SXR imaging systems as well. Software enabling live calculation of the SNR during the image acquisition might be introduced in future in the compact imaging systems for optimal image acquisition or for benchmarking purposes.
引用
收藏
页数:15
相关论文
共 38 条
  • [1] Aritome H., 1992, SPRINGER SER OPT SCI, V67, P199
  • [2] Attwood D., 1999, SOFT XRAYS EXTREME U
  • [3] Berglund M, 2000, J MICROSC-OXFORD, V197, P268, DOI 10.1046/j.1365-2818.2000.00675.x
  • [4] Real space soft x-ray imaging at 10 nm spatial resolution
    Chao, W.
    Fischer, P.
    Tyliszczak, T.
    Rekawa, S.
    Anderson, E.
    Naulleau, P.
    [J]. OPTICS EXPRESS, 2012, 20 (09): : 9777 - 9783
  • [5] Signal-to-noise measurements in magnitude images from NMR phased arrays
    Constantinides, CD
    Atalar, E
    McVeigh, ER
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (05) : 852 - 857
  • [6] X-RAY LASER MICROSCOPY OF RAT SPERM NUCLEI
    DASILVA, LB
    TREBES, JE
    BALHORN, R
    MROWKA, S
    ANDERSON, E
    ATTWOOD, DT
    BARBEE, TW
    BRASE, J
    CORZETT, M
    GRAY, J
    KOCH, JA
    LEE, C
    KERN, D
    LONDON, RA
    MACGOWAN, BJ
    MATTHEWS, DL
    STONE, G
    [J]. SCIENCE, 1992, 258 (5080) : 269 - 271
  • [7] Heck J M, 1998, J Xray Sci Technol, V8, P95
  • [8] Signal-to-noise and radiation exposure considerations in conventional and diffraction x-ray microscopy
    Huang, Xiaojing
    Miao, Huijie
    Steinbrener, Jan
    Nelson, Johanna
    Shapiro, David
    Stewart, Andrew
    Turner, Joshua
    Jacobsen, Chris
    [J]. OPTICS EXPRESS, 2009, 17 (16): : 13541 - 13553
  • [9] Design and performance of a laser-plasma-based compact soft x-ray microscope
    Johansson, GA
    Holmberg, A
    Hertz, HM
    Berglund, M
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (03) : 1193 - 1197
  • [10] Compact soft x-ray transmission microscopy with sub-50 nm spatial resolution
    Kim, KW
    Kwon, Y
    Nam, KY
    Lim, JH
    Kim, KG
    Chon, KS
    Kim, BH
    Kim, DE
    Kim, J
    Ahn, BN
    Shin, HJ
    Rah, S
    Kim, KH
    Chae, JS
    Gweon, DG
    Kang, DW
    Kang, SH
    Min, JY
    Choi, KS
    Yoon, SE
    Kim, EN
    Namba, Y
    Yoon, KH
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (06) : N99 - N107