Identification of infants with significant refractive error and strabismus in a population screening program using noncycloplegic videorefraction and orthoptic examination

被引:28
作者
Anker, S
Atkinson, J
Braddick, O
Ehrlich, D
Hartley, T
Nardini, A
Wade, J
机构
[1] UCL, Dept Psychol, Visual Dev Unit, London WC1E 6BT, England
[2] Addenbrookes Hosp, Ophthalm Dept, Cambridge, England
关键词
D O I
10.1167/iovs.02-0070
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. The second Cambridge Infant Vision Screening Program examined whether screening for accommodative errors by using videorefraction without cycloplegia could effectively serve as a first stage of screening for refractive errors, measured by standard cycloplegic retinoscopy. The screening also included an orthoptic examination for detection of strabismus. METHODS. All infants born in the Cambridge (UK) Health District, over a 2-year period, were invited for screening. Of those 5142 (76%) with mean age 8.1 +/- 0.8 months (SD) attended and received noncycloplegic videorefraction and an orthoptic examination. All those with a focusing error or orthoptic problem, as well as a randomly selected sample of visually normal control subjects, were invited to follow-up a month later for cycloplegic retinoscopy, repeat noncycloplegic videorefraction and orthoptic examination. RESULTS. Of the 5142 screened, 514 had a focusing error or orthoptic problem (positives). Four hundred thirty-nine of these and 284 visually normal control subjects (negatives) attended follow-up. A refractive or orthoptic condition was confirmed in 59.0% of the positive cases, whereas infants in 96.8% of the negative cases were confirmed normal. Adjusting for the proportions of the population represented by those infants seen at follow-tip, sensitivity for the screening procedure was calculated at 0.67 and specificity at 0.96. Detailed results are presented in terms of the different conditions detected at screening (far, near, and anisometropic focus and orthoptic error), distribution of greatest axes at screening, and a comparison of initial videorefraction with repeat videorefraction and cycloplegic retinoscopy. CONCLUSIONS. A noncycloplegic screening procedure, simpler to perform than cycloplegic screening, succeeded in detecting a large proportion of infants with significant ametropia, particularly those with significant hyperopia, which is considered to be a strabismogenic and amblyogenic risk factor.
引用
收藏
页码:497 / 504
页数:8
相关论文
共 40 条
  • [1] REFRACTION CHANGES IN CHILDREN DEVELOPING CONVERGENT OR DIVERGENT STRABISMUS
    ABRAHAMSSON, M
    FABIAN, G
    SJOSTRAND, J
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1992, 76 (12) : 723 - 727
  • [2] SCREENING FOR REFRACTIVE ERRORS IN 6-9-MONTH-OLD INFANTS BY PHOTOREFRACTION
    ATKINSON, J
    BRADDICK, OJ
    DURDEN, K
    WATSON, PG
    ATKINSON, S
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1984, 68 (02) : 105 - 112
  • [3] Atkinson J., 1996, Investigative Ophthalmology and Visual Science, V37, pS1111
  • [4] Two infant vision screening programmes: Prediction and prevention of strabismus and amblyopia from photo- and video refractive screening
    Atkinson, J
    Braddick, O
    Bobier, B
    Anker, S
    Ehrlich, D
    King, J
    Watson, P
    Moore, A
    [J]. EYE, 1996, 10 : 189 - 198
  • [5] Atkinson J, 2000, INVEST OPHTH VIS SCI, V41, pS327
  • [6] ATKINSON J, 1994, STRABISMUS, V2, P42
  • [7] Atkinson J., 1993, EARLY VISUAL DEV NOR, P335
  • [8] Atkinson Janette, 2002, Strabismus, V10, P187, DOI 10.1076/stra.10.3.187.8125
  • [9] HOW EXACT IS PHOTOREFRACTION IN INFANTS WHEN COMPARED TO RETINOSCOPY, AND HOW DO THE VALUES CHANGE WITHIN THE PERIOD OF 6 MONTHS
    BISCHOFF, P
    ALTHAUS, K
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1994, 205 (03) : 128 - 132
  • [10] BOBIER WR, 1992, CLIN VISION SCI, V7, P225