A Simple and Sensitive Paper-Based Bipolar Electrochemiluminescence Biosensor for Detection of Oxidase-Substrate Biomarkers in Serum

被引:33
作者
Wang, Dan
Liu, Cuiling
Liang, Yi
Su, Yan
Shang, Qiuping
Zhang, Chunsun [1 ]
机构
[1] South China Normal Univ, Coll Biophoton, MOE Key Lab Laser Life Sci, Guangzhou 510631, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
SCREEN-PRINTED ELECTRODES; ELECTROGENERATED-CHEMILUMINESCENCE; LACTATE DETERMINATION; GRAPHENE OXIDE; QUANTUM DOTS; CHOLESTEROL; CHOLINE; LUMINOL; PLATFORM; GLUCOSE;
D O I
10.1149/2.0551809jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Nowadays, the bipolar electrochemiluminescence (BP-ECL) is basically performed in complicated and expensive microfluidic devices, which may limit its wide applications. Here, a paper-based BP-ECL biosensor using "U"-shaped bipolar electrode (BPE) is developed for detection of oxidase-substrate biomarkers in human serum samples, with no need for complicated and expensive microfluidic technologies and peripheral apparatuses. The BP-ECL paper chips (PCs) can be well fabricated by two screen-printing processes: wax-screen-printing for on-paper hydrophilic and hydrophobic patterns, and carbon ink-screen-printing for BPEs and driving electrodes on wax-patterned paper. A low-cost and portable CCD is used to detect ECL signals from the luminol-H2O2 reaction at the BPE anodic pole. Under optimized conditions, the paper-based BP-ECL biosensor can measure the concentrations of H2O2, with a linear range of 5-10000 mu M and a detection limit of 0.424 mu M. Importantly, the biosensor is capable of achieving a linear range of 10-5000 mu M for choline, lactate or cholesterol; and the respectively corresponding detection limits are 0.573 11M, 3.132 mu M and 7.418 mu M. Moreover, it has an acceptable detection range, sensitivity, stability and selectivity. Finally, the developed method is successfully applied for determination of choline, lactate or cholesterol in human serum. (C) 2018 The Electrochemical Society.
引用
收藏
页码:B361 / B369
页数:9
相关论文
共 59 条
[1]   Modified fractal iron oxide magnetic nanostructure: A novel and high performance platform for redox protein immobilization, direct electrochemistry and bioelectrocatalysis application [J].
Bagheri, Hasan ;
Ranjbari, Elias ;
Amiri-Aref, Mohaddeseh ;
Hajian, Ali ;
Ardakani, Yalda Hosseinzadeh ;
Amidi, Salimeh .
BIOSENSORS & BIOELECTRONICS, 2016, 85 :814-821
[2]   Disposable electrochemiluminescent biosensor for lactate determination in saliva [J].
Ballesta Claver, J. ;
Valencia Miron, M. C. ;
Capitan-Vallvey, L. F. .
ANALYST, 2009, 134 (07) :1423-1432
[3]   Electrochemiluminescent disposable cholesterol biosensor based on avidin-biotin assembling with the electroformed luminescent conducting polymer poly(luminol-biotinylated pyrrole) [J].
Ballesta-Claver, J. ;
Ametis-Cabello, J. ;
Morales-Sanfrutos, J. ;
Megia-Fernandez, A. ;
Valencia-Miron, M. C. ;
Santoyo-Gonzalez, F. ;
Capitan-Vallvey, L. F. .
ANALYTICA CHIMICA ACTA, 2012, 754 :91-98
[4]   SPE biosensor for cholesterol in serum samples based on electrochemiluminescent luminol copolymer [J].
Ballesta-Claver, J. ;
Salinas Velazquez, P. ;
Valencia-Miron, M. C. ;
Capitan-Vallvey, L. F. .
TALANTA, 2011, 86 :178-185
[5]   Generation of electrochemiluminescence at bipolar electrodes: concepts and applications [J].
Bouffier, Laurent ;
Arbault, Stephane ;
Kuhn, Alexander ;
Sojic, Neso .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (25) :7003-7011
[6]   Portable reconfigurable instrument for analytical determinations using disposable electrochemiluminescent screen-printed electrodes [J].
Carvajal, M. A. ;
Ballesta-Claver, J. ;
Morales, D. P. ;
Palma, A. J. ;
Valencia-Miron, M. C. ;
Capitan-Vallvey, L. F. .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 169 :46-53
[7]   Paper-based bipolar electrode-electrochemiluminescence (BPE-ECL) device with battery energy supply and smartphone read-out: A handheld ECL system for biochemical analysis at the point-of-care level [J].
Chen, Lu ;
Zhang, Chunsun ;
Xing, Da .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 237 :308-317
[8]   Screen-printed electrode microarray for electrochemiluminescent measurements [J].
Corgier, BP ;
Marquette, CA ;
Blum, LJ .
ANALYTICA CHIMICA ACTA, 2005, 538 (1-2) :1-7
[9]   Dual Enzymatic Detection by Bulk Electrogenerated Chemiluminescence [J].
de Poulpiquet, Anne ;
Diez-Buitrago, Beatriz ;
Milutinovic, Milena Dumont ;
Sentic, Milica ;
Arbault, Stephane ;
Bouffier, Laurent ;
Kuhn, Alexander ;
Sojic, Neso .
ANALYTICAL CHEMISTRY, 2016, 88 (12) :6585-6592
[10]   Amplified electrochemiluminescence of quantum dots by electrochemically reduced graphene oxide for nanobiosensing of acetylcholine [J].
Deng, Shengyuan ;
Lei, Jianping ;
Cheng, Lingxiao ;
Zhang, Yangyang ;
Ju, Huangxian .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (11) :4552-4558