A new irradiation unit constructed of self-moving gantry-CT and linac

被引:81
作者
Kuriyama, K
Onishi, H
Sano, N
Komiyama, T
Aikawa, Y
Tateda, Y
Araki, T
Uematsu, M
机构
[1] Univ Yamanashi, Sch Med, Dept Radiat Oncol, Yamanashi, Japan
[2] Natl Def Med Coll, Dept Radiol, Div Radiat Oncol, Tokorozawa, Saitama 359, Japan
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2003年 / 55卷 / 02期
关键词
stereotactic irradiation; integrated CT-linac irradiation system; self-moving gantry CT;
D O I
10.1016/S0360-3016(02)03987-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To improve reproducibility in stereotactic irradiation (STI) without using noninvasive immobilization devices or body frames, we have developed an integrated computed tomography (CT)-linac irradiation system connecting CT scanner and linac via a common treatment couch. Methods and Materials: This system consists of a linac, a CT scanner, and a common treatment couch. The linac and the CT gantry are positioned on opposite ends of the couch so that, by rotating the treatment couch, linac radiotherapy or CT scanning can be performed. The rotational axis of the linac gantry is coaxial with that of the CT gantry, and the position of the linac isocenter on the couch matches the origin of the coordinate system for CT scanning when the couch is rotated 180degrees toward the CT side. Instead of the couch moving into the gantry, as in conventional CT, in this case the table is fixed and scanning is accomplished by moving the gantry. We evaluated the rotational accuracy of the common couch and the scan-position accuracy of the self-moving gantry CT. Results: The positional accuracy of the common couch was 0.20, 0.18, and 0.39 mm in the lateral, longitudinal, and vertical directions, respectively. The scan-position accuracy of the CT gantry was less than 0.4 mm in the lateral, longitudinal, and vertical directions. Conclusion: This irradiation system has a high accuracy and is useful for noninvasive STI and for verification of the position of a target in three-dimensional conformal radiotherapy. (C) 2003 Elsevier Science Inc.
引用
收藏
页码:428 / 435
页数:8
相关论文
共 8 条
  • [1] COEN WH, 2001, RADIOTHER ONCOL, V58, P105
  • [2] The effectiveness of an immobilization device in conformal radiotherapy for lung tumor: Reduction of respiratory tumor movement and evaluation of the daily setup accuracy
    Negoro, Y
    Nagata, Y
    Aoki, T
    Mizowaki, T
    Araki, N
    Takayama, K
    Kokubo, M
    Yano, S
    Koga, S
    Sasai, K
    Shibamoto, Y
    Hiraoka, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (04): : 889 - 898
  • [3] ONISHI H, UNPUB INT J RAD ONCO
  • [4] A dual computed tomography linear accelerator unit for stereotactic radiation therapy: A new approach without cranially fixated stereotactic frames
    Uematsu, M
    Fukui, T
    Shioda, A
    Tokumitsu, H
    Takai, K
    Kojima, T
    Asai, Y
    Kusano, S
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (03): : 587 - 592
  • [5] Uematsu M, 1998, CANCER-AM CANCER SOC, V82, P1062, DOI 10.1002/(SICI)1097-0142(19980315)82:6<1062::AID-CNCR8>3.0.CO
  • [6] 2-G
  • [7] Daily positioning accuracy of frameless stereotactic radiation therapy with a fusion of computed tomography and linear accelerator (focal) unit:: evaluation of z-axis with a z-marker
    Uematsu, M
    Sonderegger, M
    Shioda, A
    Tahara, K
    Fukui, T
    Hama, Y
    Kojima, T
    Wong, JR
    Kusano, S
    [J]. RADIOTHERAPY AND ONCOLOGY, 1999, 50 (03) : 337 - 339
  • [8] Intrafractional tumor position stability during computed tomography (CT)-guided frameless stereotactic radiation therapy for lung or liver cancers with a fusion of CT and linear accelerator (FOCAL) unit
    Uematsu, M
    Shioda, A
    Suda, A
    Tahara, K
    Kojima, T
    Hama, Y
    Kong, M
    Wong, JR
    Fukui, T
    Kusano, S
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (02): : 443 - 448