Computational analysis of three lamp close conduit water disinfection UV reactor

被引:5
作者
Sultan, T. [1 ]
Ahmad, Z. [1 ]
Hayat, K. [2 ]
Chaudhry, I. A. [1 ]
机构
[1] Univ Management & Technol UMT C II, Sch Engn SEN, Dept Mech Engn, Lahore 54770, Pakistan
[2] Univ Lahore UOL, Mech Engn Dept, Lahore, Pakistan
关键词
CFD; Fluence rate; Reactor design; Turbulence modeling; UV lamp; Water disinfection; FLUENCE RATE DISTRIBUTIONS; ULTRAVIOLET REACTORS; SURFACE-ROUGHNESS; FLUID-DYNAMICS; DRINKING-WATER; PERFORMANCE; INACTIVATION; IMPACT;
D O I
10.1007/s13762-021-03344-9
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of ultraviolet (UV) disinfection is to bring to end the growth and procreation of microorganism. UV reactors are used for the UV disinfection of the drinking water. Our goal of the current research work was properly locating the positions of the UV lamps in a three-lamp close conduit water disinfection UV reactor. Three positions of UV lamps are based on vertices of the four basic types of triangles (Equilateral, Right angle, Scalene and Isosceles). The objective function for optimized lamp positioning was Reduction Equivalent Dose (RED). To ascertain efficient UV dose delivery to pathogen, water disinfection UV reactors was simulated with the aid of computational fluid dynamics. The computational investigation was achieved employing ANSYS(R) Fluent 15.0 academic version. The turbulent flow was modeled using standard k-epsilon model, fluence rate (FR) was modeled using UVCalc3D model and pathogen transport was modeled using discrete phase model. The scalene lamp positioning results in highest RED value and isosceles lamp positioning results in lowest RED value. There is meager difference between the RED values of equilateral and scalene lamp positioning. Moreover, we found two lamps on the upstream side and one lamp on the downstream side results in better UV disinfection. The proposed methodology for the three-lamp model provides useful insights to the design and optimization of close conduit water disinfection UV reactor. This research work has evaluated, for the first time, a systematic methodology for three-lamp positioning to ameliorate the performance of UV reactor and has revitalized the comprehension about the contribution of FR distribution within the UV reactor.
引用
收藏
页码:4393 / 4406
页数:14
相关论文
共 38 条
  • [1] Stochastic Evaluation of Disinfection Performance in Large-Scale Open-Channel UV Photoreactors
    Ahmed, Yousra M.
    Ortiz, Angela P.
    Blatchley, Ernest R., III
    [J]. JOURNAL OF ENVIRONMENTAL ENGINEERING, 2019, 145 (10)
  • [2] [Anonymous], 2006, ULTRAVIOLET DISINFEC
  • [3] Ansys AF, 2015, ANSYS FLUENT AC RES
  • [4] The impact of UV treatment on microbial control and DBPs formation in full-scale drinking water systems in northern China
    Ao, Xiuwei
    Chen, Zhongyun
    Li, Simiao
    Li, Chen
    Lu, Zedong
    Sun, Wenjun
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCES, 2020, 87 : 398 - 410
  • [5] Analysis of the Radiation Dose in UV-Disinfection Flow Reactors
    Artichowicz, Wojciech
    Luczkiewicz, Aneta
    Sawicki, Jerzy M.
    [J]. WATER, 2020, 12 (01)
  • [6] Calculation of ultraviolet fluence rate distributions in an annular reactor: Significance of refraction and reflection
    Bolton, JR
    [J]. WATER RESEARCH, 2000, 34 (13) : 3315 - 3324
  • [7] BULL RJ, 1982, ENVIRON SCI TECHNOL, V16, pA554, DOI 10.1021/es00104a719
  • [8] UV dose effects on the revival characteristics of microorganisms in darkness after UV disinfection: Evidence from a pilot study
    Chen, Peng-Fei
    Zhang, Rui-Jian
    Huang, Shao-Bin
    Shao, Jun-Hua
    Cui, Bin
    Du, Zhi-Li
    Xue, Liang
    Zhou, Na
    Hou, Bin
    Lin, Chong
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 713 (713)
  • [9] Alternative approaches to modeling fluence distribution and microbial inactivation in ultraviolet reactors: Lagrangian versus Eulerian
    Ducoste, JJ
    Liu, D
    Linden, K
    [J]. JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2005, 131 (10): : 1393 - 1403
  • [10] DVGW, 2006, UV GERATE DESINFEKTI