Ti/TiO2 Nanotube Array/Ni Composite Electrodes for Nonenzymatic Amperometric Glucose Sensing

被引:155
作者
Wang, Chengxiang [1 ]
Yin, Longwei [1 ]
Zhang, Luyuan [1 ]
Gao, Rui [1 ]
机构
[1] Shandong Univ, Sch Mat Sci & Engn, Minist Educ, Key Lab Liquid Solid Struct Evolut & Proc Mat, Jinan 250061, Peoples R China
关键词
SOL-GEL MATRIX; ENANTIOMERIC ELECTROOXIDATION; HYDROGEN-PEROXIDE; IMMOBILIZATION; BIOSENSOR; TIO2; NI; OXIDASE; SENSOR; FILM;
D O I
10.1021/jp912232p
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
TiO2 nantube arrays (NTAs) with a tube diameter of about 100 nm were prepared by anodic oxidation, and a Ni layer about several tells of micrometers thick was electrodeposited oil the Surface of TiO2 NTAs. The synthesized Ti/TiO2 NTA/Ni composite electrodes were used for nonenzymatic glucose detection. The behavior of the anodic TiO2 NTA/substrate Ti metal is analogous to characteristics of an n-type semiconductor/metal Schottky barrier diode. The characteristic Would enhance the rapid transport of surface reaction electrons to the metal substrate, thereby enhancing the performance of biosensors. Cyclic voltammogram investigations indicate that calcined Ti/TiO2 NTAs have a wider work potential window than that of Ti/TiO2 NTAs without calcinations and Ti foils. Moreover, the low saturated current in alkaline Solutions Under a constant potential makes Ti/TiO2 NTAs Favorable as substrate materials for biosensors. For the Ti/TiO2 NTA/Ni composite electrodes, the relationship between the linear range and the potential was investigated. The positive line scans and the amperometric response curves to glucose indicated that I potential of 0.5-0.6 V Would be Favorable to get a wide linear range for detecting glucose. The sensitivity of the composite electrodes call reach a Value as high as 200 mu A mM(-1) cm(-2), and the detection limit wits about 4 PM with it signal-to-noise ratio of 3 (S/N = 3). The present Ti/TiO2 NTA/Ni composite flonenzymatic amperometric glucose sensor Could find potential applications in a good biosensing platform for other redox proteins and enzymes.
引用
收藏
页码:4408 / 4413
页数:6
相关论文
共 27 条
[1]   Temperature effects in the enantiomeric electro-oxidation of D- and L-glucose on Pt{643}S [J].
Attard, GA ;
Ahmadi, A ;
Feliu, J ;
Rodes, A ;
Herrero, E ;
Blais, S ;
Jerkiewicz, G .
JOURNAL OF PHYSICAL CHEMISTRY B, 1999, 103 (09) :1381-1385
[2]   High performance glucose biosensor based on the immobilization of glucose oxidase onto modified titania nanotube arrays [J].
Benvenuto, Paul ;
Kafi, A. K. M. ;
Chen, Aicheng .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 627 (1-2) :76-81
[3]   A Glucose Biosensor Based on Immobilization of Glucose Oxidase into 3D Macroporous TiO2 [J].
Cao, Huimin ;
Zhu, Yihua ;
Tang, Longhua ;
Yang, Xiaoling ;
Li, Chunzhong .
ELECTROANALYSIS, 2008, 20 (20) :2223-2228
[4]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[5]   Impedance spectroscopy analysis of glucose electro-oxidation on Ni-modified glassy carbon electrode [J].
Danaee, I. ;
Jafarian, M. ;
Forouzandeh, F. ;
Gobal, F. ;
Mahjani, M. G. .
ELECTROCHIMICA ACTA, 2008, 53 (22) :6602-6609
[6]   Electrocatalytic oxidation of methanol at a nickel hydroxide/glassy carbon modified electrode in alkaline medium [J].
El-Shafei, AA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 471 (02) :89-95
[7]   INSITU UV VISIBLE REFLECTANCE SPECTROSCOPIC INVESTIGATION OF THE NICKEL ELECTRODE ALKALINE-SOLUTION INTERFACE [J].
HAHN, F ;
BEDEN, B ;
CROISSANT, MJ ;
LAMY, C .
ELECTROCHIMICA ACTA, 1986, 31 (03) :335-342
[8]   A nano-Ni based ultrasensitive nonenzymatic electrochemical sensor for glucose: Enhancing sensitivity through a nanowire array strategy [J].
Lu, Li-Min ;
Zhang, Li ;
Qu, Feng-Li ;
Lu, Hai-Xia ;
Zhang, Xiao-Bing ;
Wu, Zai-Sheng ;
Huan, Shuang-Yan ;
Wang, Qiu-An ;
Shen, Guo-Li ;
Yu, Ru-Qin .
BIOSENSORS & BIOELECTRONICS, 2009, 25 (01) :218-223
[9]   NICKEL-TITANIUM ALLOY ELECTRODE AS A SENSITIVE AND STABLE LC-EC DETECTOR FOR CARBOHYDRATES [J].
LUO, PFF ;
KUWANA, T .
ANALYTICAL CHEMISTRY, 1994, 66 (17) :2775-2782
[10]   Filling of TiO2 nanotubes by self-doping and electrodeposition [J].
Macak, Jan M. ;
Gong, Bin G. ;
Hueppe, Michael ;
Schmuki, Patrik .
ADVANCED MATERIALS, 2007, 19 (19) :3027-+