Planning target volume margins for prostate radiotherapy using daily electronic portal imaging and implanted fiducial markers

被引:45
作者
Skarsgard, David [1 ,2 ]
Cadman, Pat [3 ]
El-Gayed, Ali [4 ]
Pearcey, Robert [5 ]
Tai, Patricia [6 ]
Pervez, Nadeem [5 ]
Wu, Jackson [1 ,2 ]
机构
[1] Tom Baker Canc Clin, Dept Radiat Oncol, Calgary, AB T2N 4N2, Canada
[2] Univ Calgary, Calgary, AB T2N 4N2, Canada
[3] Saskatoon Canc Ctr, Dept Med Phys, Saskatoon, SK S7N 4H4, Canada
[4] Saskatoon Canc Ctr, Dept Radiat Oncol, Saskatoon, SK S7N 4H4, Canada
[5] Cross Canc Inst, Dept Radiat Oncol, Edmonton, AB T6G 1Z2, Canada
[6] Allan Blair Canc Ctr, Dept Radiat Oncol, Regina, SK S4T 7T1, Canada
关键词
CONFORMAL RADIOTHERAPY; INTRAFRACTION MOTION; RADIATION-THERAPY; CANCER PATIENTS; DOSE-RESPONSE; INTERFRACTION; TRIAL; VERIFICATION; POSITION; ERROR;
D O I
10.1186/1748-717X-5-52
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Fiducial markers and daily electronic portal imaging (EPI) can reduce the risk of geographic miss in prostate cancer radiotherapy. The purpose of this study was to estimate CTV to PTV margin requirements, without and with the use of this image guidance strategy. Methods: 46 patients underwent placement of 3 radio-opaque fiducial markers prior to prostate RT. Daily pretreatment EPIs were taken, and isocenter placement errors were corrected if they were >= 3 mm along the left-right or superior-inferior axes, and/or >= 2 mm along the anterior-posterior axis. During-treatment EPIs were then obtained to estimate intra-fraction motion. Results: Without image guidance, margins of 0.57 cm, 0.79 cm and 0.77 cm, along the left-right, superior-inferior and anterior-posterior axes respectively, are required to give 95% probability of complete CTV coverage each day. With the above image guidance strategy, these margins can be reduced to 0.36 cm, 0.37 cm and 0.37 cm respectively. Correction of all isocenter placement errors, regardless of size, would permit minimal additional reduction in margins. Conclusions: Image guidance, using implanted fiducial markers and daily EPI, permits the use of narrower PTV margins without compromising coverage of the target, in the radiotherapy of prostate cancer.
引用
收藏
页数:11
相关论文
共 24 条
[1]   Measurements of intrafraction motion and interfraction and intrafraction rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers [J].
Aubry, JF ;
Beaulieu, L ;
Girouard, LM ;
Aubin, S ;
Tremblay, D ;
Laverdière, J ;
Vigneault, E .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01) :30-39
[2]   Planning target margin calculations for prostate radiotherapy based on intrafraction and interfraction motion using four localization methods [J].
Beltran, Chris. ;
Herman, Michael G. ;
Davis, Brian J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (01) :289-295
[3]   Individualized planning target volumes for intrafraction motion during hypofractionated intensity-modulated radiotherapy boost for prostate cancer [J].
Cheung, P ;
Sixel, K ;
Morton, G ;
Loblaw, DA ;
Tirona, R ;
Pang, G ;
Choo, R ;
Szumacher, E ;
DeBoer, G ;
Pignol, JP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (02) :418-425
[4]   On-line aSi portal imaging of implanted fiducial markers for the reduction of interfraction error during conformal radiotherapy of prostate carcinoma [J].
Chung, PWM ;
Haycocks, T ;
Brown, T ;
Cambridge, Z ;
Kelly, V ;
Alasti, H ;
Jaffray, DA ;
Catton, CN .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01) :329-334
[5]   Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI) [J].
Ghilezan, MJ ;
Jaffray, DA ;
Siewerdsen, JH ;
van Herk, M ;
Shetty, A ;
Sharpe, MB ;
Jafri, SZ ;
Vicini, FA ;
Matter, RC ;
Brabbins, DS ;
Martinez, AA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (02) :406-417
[6]   Potentials of on-line repositioning based on implanted fiducial markers and electronic portal imaging in prostate cancer radiotherapy [J].
Graf, Reinhold ;
Wust, Peter ;
Budach, Volker ;
Boehmer, Dirk .
RADIATION ONCOLOGY, 2009, 4
[7]   Intrafraction prostate motion during IMRT for prostate cancer [J].
Huang, E ;
Dong, L ;
Chandra, A ;
Kuban, DA ;
Rosen, II ;
Evans, A ;
Pollack, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (02) :261-268
[8]   Long-term results of the M. D. Anderson randomized dose-escalation trial for prostate cancer [J].
Kuban, Deborah A. ;
Tucker, Susan L. ;
Dong, Lei ;
Starkschall, George ;
Huang, Eugene E. ;
Cheung, M. Rex ;
Lee, Andrew K. ;
Pollack, Alan .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (01) :67-74
[9]   Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients [J].
Létourneau, D ;
Martinez, AA ;
Lockman, D ;
Yan, D ;
Vargas, C ;
Ivaldi, G ;
Wong, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (04) :1239-1246
[10]   Influence of intrafraction motion on margins for prostate radiotherapy [J].
Litzenberg, DW ;
Balter, JM ;
Hadley, SW ;
Sandler, HM ;
Willoughby, TR ;
Kupelian, PA ;
Levine, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02) :548-553