Development of a diagnostic system for bilirubin detection in cerebral spinal fluid

被引:2
作者
Bhadri, PR [1 ]
Salgaonkar, VA [1 ]
Majumdar, A [1 ]
Morgan, CJ [1 ]
Zuccarello, M [1 ]
Pyne, GJ [1 ]
Dulaney, E [1 ]
Caffery, J [1 ]
Clark, JF [1 ]
Shukla, R [1 ]
Beyette, FR [1 ]
机构
[1] Univ Cincinnati, Coll Engn, Dept ECECS, Cincinnati, OH 45221 USA
来源
APPLICATIONS OF DIGITAL IMAGE PROCESSING XXVII, PTS 1AND 2 | 2004年 / 5558卷
关键词
bilirubin; spinal fluid; hemoglobin; UV spectrometry; Beer's law; regression; multivariate; linear; derivative analysis; minimum distance;
D O I
10.1117/12.561136
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
A weakened portion of an artery in the brain leads to a medical condition known as a cerebral aneurysm. A subarachnoid hemorrhage (SAH) occurs when an aneurysm ruptures. For those individuals suspected of having a SAH, a computerized tomography (CT) scan of the brain usually demonstrates evidence of the bleeding. However, in a considerable portion of people, the CT scan is unable to detect the blood that has escaped from the blood vessel. Recent studies have indicated nearly 30% of patients with a SAH are initially misdiagnosed. For circumstances when a SAH is suspected despite a normal CT scan, physicians make the diagnosis of SAH by performing a spinal tap. A spinal tap uses a needle to sample the cerebrospinal fluid (CSF) collected from the patient's lumbar spine. However, it is also possible for blood to be introduced into the CSF as a result of the spinal tap procedure. Therefore, an effective solution is required to help medical personnel differentiate between the blood that results from a tap and that from a ruptured aneurysm. In this paper, the development of a prototype is described which is sensitive and specific for measuring bilirubin in CSF, hemorrhagic-CSF and CSF-like solutions. To develop this instrument a combination of spectrophotometric analysis, custom data analysis software and other hardware interfaces are assembled that lay the foundation for the development of portable and user-friendly equipment suitable for assisting trained medical personnel with the diagnosis of a ruptured cerebral aneurysm.
引用
收藏
页码:236 / 247
页数:12
相关论文
共 23 条
[1]   PITFALLS IN THE RECOGNITION OF SUBARACHNOID HEMORRHAGE [J].
ADAMS, HP ;
JERGENSON, DD ;
KASSELL, NF ;
SAHS, AL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1980, 244 (08) :794-796
[2]  
AMEROV AK, INT C HOL CORR OPT R, V2108, P521
[3]   Derivative spectrophotometric analysis of cerebrospinal fluid for the detection of a ruptured cerebral aneurysm [J].
Bhadri, PR ;
Majumder, A ;
Morgan, CJ ;
Pyne, GJ ;
Zuccarello, M ;
Jauch, E ;
Wagner, KR ;
Clark, JF ;
Caffery, J ;
Beyette, FR .
OPTICAL INFORMATION SYSTEMS, 2003, 5202 :381-392
[4]  
CLARK JF, 1992, BIOCHIM BIOPHYS ACTA, V1100, P137
[5]   Oxidation of bilirubin produces compounds that cause prolonged vasospasm of rat cerebral vessels: A contributor to subarachnoid hemorrhage-induced vasospasm [J].
Clark, JF ;
Reilly, M ;
Sharp, FR .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2002, 22 (04) :472-478
[6]   Primary care: Avoiding pitfalls in the diagnosis of subarachnoid hemorrhage [J].
Edlow, JA ;
Caplan, LR .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (01) :29-36
[7]  
HAM FM, 1997, BIOMEDICAL ENG IEEE, V6, P475
[8]   On neurobiological, neuro-fuzzy, machine learning, and statistical pattern recognition techniques [J].
Joshi, A ;
Ramakrishman, N ;
Houstis, EN ;
Rice, JR .
IEEE TRANSACTIONS ON NEURAL NETWORKS, 1997, 8 (01) :18-31
[9]   DELAY IN REFERRAL OF PATIENTS WITH RUPTURED ANEURYSMS TO NEUROSURGICAL ATTENTION [J].
KASSELL, NF ;
KONGABLE, GL ;
TORNER, JC ;
ADAMS, HP ;
MAZUZ, H .
STROKE, 1985, 16 (04) :587-590
[10]  
KRAMER R, CHEMOMETRIC TECHNIQU