Design of a CMOS potentiostat circuit for electrochemical detector arrays

被引:78
作者
Ayers, Sunitha [1 ]
Gillis, Kevin D.
Lindau, Manfred
Minch, Bradley A.
机构
[1] Cornell Univ, Sch Elect & Comp Engn, Ithaca, NY 14853 USA
[2] Univ Missouri, Columbia, MO 65211 USA
[3] Cornell Univ, Sch Engn & Appl Phys, Ithaca, NY 14853 USA
[4] Franklin W Olin Coll Engn, Needham, MA 02492 USA
关键词
amperometry; biosensor; CMOS potentiostat array; electrochemical detector;
D O I
10.1109/TCSI.2006.888777
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High-throughput electrode arrays are required for advancing devices for testing the effect of drugs on cellular function. In this paper, we present design criteria for a potentiostat circuit that is capable of measuring transient amperometric oxidation currents at the surface of an electrode with submillisecond time resolution and picoampere current resolution. The potentiostat is a regulated cascode stage in which a high-gain amplifier maintains the electrode voltage through a negative feedback loop. The potentiostat uses a new shared amplifier structure in which all of the amplifiers in a given row of detectors share a common half circuit permitting us to use fewer transistors per detector. We also present measurements from a test chip that was fabricated in a 0.5-mu m, 5-V CMOS process through MOSIS. Each detector occupied a layout area of 35 mu m x 15 mu m and contained eight transistors and a 50-fF integrating capacitor. The rms current noise at 2-kHz bandwidth is approximate to 110 fA. The maximum charge storage capacity at 2 kHz is 1.26 x 10(6) electrons.
引用
收藏
页码:736 / 744
页数:9
相关论文
共 25 条
[1]   The exocytotic event in chromaffin cells revealed by patch amperometry [J].
Albillos, A ;
Dernick, G ;
Horstmann, H ;
Almers, W ;
deToledo, GA ;
Lindau, M .
NATURE, 1997, 389 (6650) :509-512
[2]  
Bandyopadhyay A, 2002, 2002 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL II, PROCEEDINGS, P740
[3]   FAST-SCAN VOLTAMMETRY OF BIOGENIC-AMINES [J].
BAUR, JE ;
KRISTENSEN, EW ;
MAY, LJ ;
WIEDEMANN, DJ ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1988, 60 (13) :1268-1272
[4]  
BOEMLER C, 2005, Patent No. 6965407
[5]  
Breten M, 2000, ISCAS 2000: IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS - PROCEEDINGS, VOL V, P709, DOI 10.1109/ISCAS.2000.857591
[6]  
CHOW CH, 1995, SINGLE CHANNEL RECOR, P245
[7]   DELAY IN VESICLE FUSION REVEALED BY ELECTROCHEMICAL MONITORING OF SINGLE SECRETORY EVENTS IN ADRENAL CHROMAFFIN CELLS [J].
CHOW, RH ;
VONRUDEN, L ;
NEHER, E .
NATURE, 1992, 356 (6364) :60-63
[8]   Patch amperometry: high-resolution measurements of single-vesicle fusion and release [J].
Dernick, G ;
Gong, LW ;
Tabares, L ;
de Toledo, GA ;
Lindau, M .
NATURE METHODS, 2005, 2 (09) :699-708
[9]   Electrochemical imaging of fusion pore openings by electrochemical detector arrays [J].
Hafez, I ;
Kisler, K ;
Berberian, K ;
Dernick, G ;
Valero, V ;
Yong, MG ;
Craighead, HG ;
Lindau, M .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2005, 102 (39) :13879-13884
[10]   Focal-plane-arrays and CMOS readout techniques of infrared imaging systems [J].
Hsieh, CC ;
Wu, CY ;
Jih, FW ;
Sun, TP .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS FOR VIDEO TECHNOLOGY, 1997, 7 (04) :594-605