Three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever

被引:12
作者
Park, Ji-Man [1 ]
Kim, Hyun-Joo
Park, Eun-Jin [1 ]
Kim, Myung-Rae [2 ]
Kim, Sun-Jong [2 ]
机构
[1] Ewha Womans Univ, Dept Prosthodont, Seoul 158710, South Korea
[2] Ewha Womans Univ, Dept Oral & Maxillofacial Surg, Seoul 158710, South Korea
关键词
Finite element analysis; Implant prosthesis; Cantilever; Stress distribution; FIXED PARTIAL PROSTHESES; DENTAL IMPLANT; OSSEOINTEGRATED IMPLANTS; LENGTH; BONE; REDUCTION; RIDGES; SYSTEM;
D O I
10.4047/jap.2014.6.5.361
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. In case of large horizontal discrepancy of alveolar ridge due to severe resorption, cantilevered crown is usually an unavoidable treatment modality. The purpose of this study was to evaluate the clinical criteria for the placement of the aforementioned implant crown. MATERIALS AND METHODS. The mandible model with 2 mm thick cortical bone and cancel bus bone was fabricated from CT cross-section image. An external connection type implant was installed and cantilevered crowns with increasing offset of 3, 4, 5, 6, and 7 mm were connected. Vertical load and 30 degrees oblique load of 300 N was applied and stress around bone and implant component was analyzed. A total of 14 cases were modeled and finite element analysis was performed using COSMOS Works (Solid works Inc, USA). RESULTS. As for the location of the vertical load, the maximum stress generated on the lingual side of the implant became larger according to the increase of offset distance. When the oblique load was applied at 30 degrees, the maximum stress was generated on the buccal side and its magnitude gradually decreased as the distance of the offset load increased to 5 mm. After that point, the magnitude of implant component's stress increased gradually. CONCLUSION. The results of this study suggest that for the patient with atrophied alveolar ridge following the loss of molar teeth, von-Mises stress on implant components was the lowest under the 30 degrees oblique load at the 5 mm offset point. Further studies for the various crown height and numbers of occusal points are needed to generalize the conclusion of present study.
引用
收藏
页码:361 / 371
页数:11
相关论文
共 50 条
[41]   Three-Dimensional Finite Element Analysis of Stress Distribution in Dental Implant Prosthesis and Surrounding Bone Using PEEK Abutments [J].
Hong, Min-Ho ;
Choi, Hyunsuk .
BIOMIMETICS, 2024, 9 (08)
[42]   Influence of Cusp Inclination on Stress Distribution in Implant-Supported Prostheses. A Three-Dimensional Finite Element Analysis [J].
Falcon-Antenucci, Rosse Mary ;
Pellizzer, Eduardo Piza ;
Perri de Carvalho, Paulo Sergio ;
Goiato, Marcelo Coelho ;
Noritomi, Pedro Yoshito .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2010, 19 (05) :381-386
[43]   Bone-Implant Interface with Simulated Insertion Stress Around an Immediately Loaded Dental Implant in the Anterior Maxilla: A Three-Dimensional Finite Element Analysis [J].
Lee, Joon-Seok ;
Cho, In-Ho ;
Kim, Yung-Soo ;
Heo, Seong-Joo ;
Kwon, Ho-Beom ;
Lim, Young-Jun .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (02) :295-302
[44]   Splinted and Nonsplinted Crowns with Different Implant Lengths in the Posterior Maxilla by Three-Dimensional Finite Element Analysis [J].
Araujo Lemos, Cleidiel Aparecido ;
Verri, Fellippo Ramos ;
Santiago Junior, Joel Ferreira ;
de Souza Batista, Victor Eduardo ;
Kemmoku, Daniel Takanori ;
Noritomi, Pedro Yoshito ;
Pellizzer, Eduardo Piza .
JOURNAL OF HEALTHCARE ENGINEERING, 2018, 2018
[45]   Passivity Versus Unilateral Angular Misfit: Evaluation of Stress Distribution on Implant-Supported Single Crowns: Three-Dimensional Finite Element Analysis [J].
Gomes, Erica Alves ;
Assuncao, Wirley Goncalves ;
Ricardo Barao, Valentim Adelino ;
Delben, Juliana Aparecida ;
Rocha, Eduardo Passos ;
Capello de Sousa, Edson Antonio .
JOURNAL OF CRANIOFACIAL SURGERY, 2010, 21 (06) :1683-1687
[46]   Influence of different implant-abutment connections on stress distribution in single tilted implants and peripheral bone: A three-dimensional finite element analysis [J].
Ozturk, Ozgur ;
Kulunk, Tolga ;
Kulunk, Safak .
BIO-MEDICAL MATERIALS AND ENGINEERING, 2018, 29 (04) :513-526
[47]   Three dimensional finite element analysis of a novel osteointegrated dental implant designed to reduce stress peak of cortical bone [J].
Zheng, Li ;
Yang, Jingsong ;
Hu, Xuefeng ;
Luo, Jiaoming .
ACTA OF BIOENGINEERING AND BIOMECHANICS, 2014, 16 (03) :21-28
[48]   Impact of Bone Augmentation of Facial Bone Defect around Osseointegrated Implant: A Three Dimensional Finite Element Analysis [J].
Hudieb, Malik ;
AlKhader, Mustafa ;
Mortaja, Salah ;
Abusamak, Mohammad ;
Wakabayashi, Noriyuki ;
Kasugai, Shohei .
DENTISTRY JOURNAL, 2021, 9 (10)
[49]   Effects of different inter-implant distances on the stress distribution around endosseous implants in posterior mandible: A 3D finite element analysis [J].
Simsek, B ;
Erkmen, E ;
Yilmaz, D ;
Eser, A .
MEDICAL ENGINEERING & PHYSICS, 2006, 28 (03) :199-213
[50]   Finite Element Analysis of Stress Distribution in Cancellous Bone During Dental Implant Pilot Drilling [J].
Chethan, K. N. ;
Shetty, Nisha ;
Shetty, Divya ;
Keni, Laxmikant G. ;
Futane, Mohan ;
Adnur, Mahantesh .
PROSTHESIS, 2025, 7 (01)