Three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever

被引:11
|
作者
Park, Ji-Man [1 ]
Kim, Hyun-Joo
Park, Eun-Jin [1 ]
Kim, Myung-Rae [2 ]
Kim, Sun-Jong [2 ]
机构
[1] Ewha Womans Univ, Dept Prosthodont, Seoul 158710, South Korea
[2] Ewha Womans Univ, Dept Oral & Maxillofacial Surg, Seoul 158710, South Korea
关键词
Finite element analysis; Implant prosthesis; Cantilever; Stress distribution; FIXED PARTIAL PROSTHESES; DENTAL IMPLANT; OSSEOINTEGRATED IMPLANTS; LENGTH; BONE; REDUCTION; RIDGES; SYSTEM;
D O I
10.4047/jap.2014.6.5.361
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. In case of large horizontal discrepancy of alveolar ridge due to severe resorption, cantilevered crown is usually an unavoidable treatment modality. The purpose of this study was to evaluate the clinical criteria for the placement of the aforementioned implant crown. MATERIALS AND METHODS. The mandible model with 2 mm thick cortical bone and cancel bus bone was fabricated from CT cross-section image. An external connection type implant was installed and cantilevered crowns with increasing offset of 3, 4, 5, 6, and 7 mm were connected. Vertical load and 30 degrees oblique load of 300 N was applied and stress around bone and implant component was analyzed. A total of 14 cases were modeled and finite element analysis was performed using COSMOS Works (Solid works Inc, USA). RESULTS. As for the location of the vertical load, the maximum stress generated on the lingual side of the implant became larger according to the increase of offset distance. When the oblique load was applied at 30 degrees, the maximum stress was generated on the buccal side and its magnitude gradually decreased as the distance of the offset load increased to 5 mm. After that point, the magnitude of implant component's stress increased gradually. CONCLUSION. The results of this study suggest that for the patient with atrophied alveolar ridge following the loss of molar teeth, von-Mises stress on implant components was the lowest under the 30 degrees oblique load at the 5 mm offset point. Further studies for the various crown height and numbers of occusal points are needed to generalize the conclusion of present study.
引用
收藏
页码:361 / 371
页数:11
相关论文
共 50 条
  • [1] Association between the pen-implant bone structure and stress distribution around the mandibular canal: A three-dimensional finite element analysis
    Kinoshita, Hideaki
    Nakahara, Ken
    Matsunaga, Satoru
    Usami, Akinobu
    Yoshinari, Masao
    Takano, Naoki
    Ide, Yoshinobu
    Abe, Shinichi
    DENTAL MATERIALS JOURNAL, 2013, 32 (04) : 637 - 642
  • [2] Three-Dimensional Finite Element Analysis of Different Implant Configurations for a Mandibular Fixed Prosthesis
    Fazi, Giovanni
    Tellini, Simone
    Vangi, Dario
    Branchi, Roberto
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (04) : 752 - 759
  • [3] Effect of Offset Implant Placement on the Stress Distribution Around a Dental Implant: A Three-Dimensional Finite Element Analysis
    Siadat, Hakimeh
    Hashemzadeh, Shervin
    Geramy, Allahyar
    Bassir, Seyed Hossein
    Alikhasi, Marzieh
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (06) : 646 - 651
  • [4] Three-dimensional finite element analysis of the effects of implant diameter and photofunctionalization on peri-implant stress
    Ohyama, Tetsuo
    Yasuda, Hiroyasu
    Shibuya, Norio
    Tadokoro, Satomi
    Nakabayashi, Shinya
    Namaki, Shunsuke
    Hara, Yaeko
    Ogawa, Takahiro
    Ishigami, Tomohiko
    JOURNAL OF ORAL SCIENCE, 2017, 59 (02) : 273 - 278
  • [5] Stress Distribution due to Loading on Premolar Teeth Implant: A Three Dimensional Finite Element Analysis
    Hisam, M. J.
    Lim, J. Y.
    Kurniawan, D.
    Nor, F. M.
    2ND INTERNATIONAL MATERIALS, INDUSTRIAL, AND MANUFACTURING ENGINEERING CONFERENCE, MIMEC2015, 2015, 2 : 218 - 223
  • [6] Mandibular bone remodeling around osseointegrated functionally graded biomaterial implant using three dimensional finite element model
    Elleuch, Sameh
    Jrad, Hanen
    Wali, Mondher
    Dammak, Fakhreddine
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2023, 39 (09)
  • [7] Comparative Evaluation of Three Abutment-Implant Interfaces on Stress Distribution in and Around Different Implant Systems: A Finite Element Analysis
    Kharsan, Vishwas
    Bandgar, Vaibhav
    Mirza, Aftab
    Jagtiani, Kiran
    Dhariwal, Neha
    Kore, Rahul
    CONTEMPORARY CLINICAL DENTISTRY, 2019, 10 (04) : 590 - 594
  • [8] Three-dimensional finite element analysis of stress distribution in retention screws of different crown-implant ratios
    Moraes, S. L. D.
    Pellizzer, E. P.
    Verri, F. R.
    Santiago, J. F., Jr.
    Silva, J. V. L.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 (07) : 689 - 696
  • [9] Effect of Integration Patterns Around Implant Neck on Stress Distribution in Peri-Implant Bone: A Finite Element Analysis
    Han, Jingyun
    Sun, Yuchun
    Wang, Chao
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (06): : 549 - 558
  • [10] Finite Element Analysis of the Influence of Implant Inclination on Stress Distribution in Mandibular Overdentures
    Ebadian, Behnaz
    Mosharraf, Ramin
    Khodaeian, Niloufar
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (03) : 252 - 257