Value of 10-2 Visual Field Testing in Glaucoma Patients with Early 24-2 Visual Field Loss

被引:31
作者
West, Michael E.
Sharpe, Glen P.
Hutchison, Donna M.
Rafuse, Paul E.
Shuba, Lesya M.
Nicolela, Marcelo T.
Vianna, Jayme R.
Chauhan, Balwantray C. [1 ]
机构
[1] Dalhousie Univ, Dept Ophthalmol & Visual Sci, 1276 South Pk St,2W Victoria, Halifax, NS B3H 2Y9, Canada
基金
加拿大健康研究院;
关键词
Glaucoma; Perimetry; Receiver operating characteristic curve analysis; Sensitivity; Specificity; Visual field; 10-2; test; 24-2;
D O I
10.1016/j.ophtha.2020.08.033
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine whether the 10-2 test of the Humphrey Field Analyzer detected a higher proportion of abnormal visual fields compared with the 24-2 test in the central 10 degrees of patients with early glaucomatous visual field damage. Design: Prospective observational study. Participants: Patients with open-angle glaucoma and healthy control participants. Methods: All participants underwent a 24-2 and 10-2 test. Only the 12 central test locations of the 24-2 test were included to analyze equivalent visual field areas. The performance of the 2 tests was compared across 4 pointwise criteria: total deviation (TD) and pattern deviation (PD) analyses at the 5% and 2% levels. Analyses also were conducted for 2 pairs of follow-up tests, each performed 4 months apart. Main Outcome Measures: (1) Area under the receiver operating characteristic curve (AUC), (2) sensitivity at identically matched specificity for the 4 criteria, (3) overlap (entire field and by quadrant) of abnormal visual fields with both tests, and (4) repeatability of the findings in 2 subsequent follow-up tests. Results: One eye each of 97 glaucoma patients (median mean deviation, -2.31 dB) and 65 control participants were included in the study. The AUCs for the 24-2 and 10-2 tests were not significantly different for any of the 4 criteria and ranged from 0.88 to 0.93 and from 0.91 to 0.94, respectively. At matched specificity, the sensitivity of the 24-2 test was significantly higher for all criteria except for PD analysis at 5%. In patients with an abnormal field with either test, the overlap varied from 60% to 86% depending on the criterion, whereas by quadrant, concordance ranged from 70% to 87%. Over the follow-up, the repeatability of test results (both 24-2 and 10-2 abnormal, either abnormal, or both normal) was achieved in 55% to 70% of patients. Conclusions: In this study of glaucoma patients with early damage with the 24-2 test, there was little evidence that adding the 10-2 test revealed additional undetected defects in the central visual field. It may be more prudent to reserve 10-2 testing for following up selected patients with higher risk of central visual field progression. (C) 2020 by the American Academy of Ophthalmology
引用
收藏
页码:545 / 553
页数:9
相关论文
共 28 条
  • [1] Canadian Ophthalmological Society Glaucoma Clinical Practice Guideline Expert Committee, 2009, Can J Ophthalmol, V44 Suppl 1, pS7, DOI 10.3129/cjo44s1
  • [2] Practical recommendations for measuring rates of visual field change in glaucoma
    Chauhan, B. C.
    Garway-Heath, D. F.
    Goni, F. J.
    Rossetti, L.
    Bengtsson, B.
    Viswanathan, A. C.
    Heijl, A.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2008, 92 (04) : 569 - 573
  • [3] Choosing two points to add to the 24-2 pattern to better describe macular visual field damage due to glaucoma
    Chen, Siyuan
    McKendrick, Allison M.
    Turpin, Andrew
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2015, 99 (09) : 1236 - 1239
  • [4] Intervals between Visual Field Tests When Monitoring the Glaucomatous Patient: Wait-and-See Approach
    Crabb, David P.
    Garway-Heath, David F.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (06) : 2770 - 2776
  • [5] TOPOGRAPHY OF GANGLION-CELLS IN HUMAN RETINA
    CURCIO, CA
    ALLEN, KA
    [J]. JOURNAL OF COMPARATIVE NEUROLOGY, 1990, 300 (01) : 5 - 25
  • [6] 24-2 Visual Fields Miss Central Defects Shown on 10-2 Tests in Glaucoma Suspects, Ocular Hypertensives, and Early Glaucoma
    De Moraes, C. Gustavo
    Hood, Donald C.
    Thenappan, Abinaya
    Girkin, Christopher A.
    Medeiros, Felipe A.
    Weinreb, Robert N.
    Zangwill, Linda M.
    Liebmann, Jeffrey M.
    [J]. OPHTHALMOLOGY, 2017, 124 (10) : 1449 - 1456
  • [7] Modifying the Conventional Visual Field Test Pattern to Improve the Detection of Early Glaucomatous Defects in the Central 10°
    Ehrlich, Alyssa C.
    Raza, Ali S.
    Ritch, Robert
    Hood, Donald C.
    [J]. TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2014, 3 (06):
  • [8] Geographic Variation in the Use of Diagnostic Testing of Patients with Newly Diagnosed Open-Angle Glaucoma
    Elam, Angela R.
    Blachley, Taylor S.
    Stein, Joshua D.
    [J]. OPHTHALMOLOGY, 2016, 123 (03) : 522 - 531
  • [9] European Glaucoma Society, 2014, TERM GUID GLAUC
  • [10] Methodology and reporting of diagnostic accuracy studies of automated perimetry in glaucoma: evaluation using a standardised approach
    Fidalgo, Bruno M. R.
    Crabb, David P.
    Lawrenson, John G.
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2015, 35 (03) : 315 - 323