A Flexure-Based Parallel Actuation Dual-Stage System for Large-Stroke Nanopositioning

被引:41
作者
Zhu, Haiyue [1 ]
Pang, Chee Khiang [2 ,3 ]
Teo, Tat Joo [4 ]
机构
[1] Natl Univ Singapore, SIMTech NUS Joint Lab Precis Mot Syst, Dept Elect & Comp Engn, Singapore 117583, Singapore
[2] Singapore Inst Technol, Engn Cluster, Singapore 138682, Singapore
[3] Natl Univ Singapore, Dept Elect & Comp Engn, Singapore 117583, Singapore
[4] Agcy Sci Technol & Res, Mechatron Grp, Singapore Inst Mfg Technol, Singapore 638075, Singapore
关键词
Disturbance observer; dual-stage system; flexure mechanism; force ripple; Halbach PM array; nanopositioning; parallel actuation; sliding mode control; DISTURBANCE-OBSERVER; TRACKING CONTROL; DESIGN; OPTIMIZATION; ALIGNMENT; ARRAYS; MOTOR;
D O I
10.1109/TIE.2017.2677306
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a novel parallel actuation dual-stage system that delivers nanometric positioning over a large displacement. Unlike those traditional dual-stage designs, the translator of fine actuator in the proposed design is mechanically connected to the coarse translator via the flexure mechanism, while the actuation coils of both the coarse and fine actuators lay underneath the translators in parallel. The merits of the proposed parallel actuation dual-stage design are mainly twofold. First, both the coarse and fine actuators utilize the moving-magnet configuration, hence the translators do not need to carry any cables for power supply. Second, the coarse motion can exhibit better dynamics and energy efficiency due to the minimized moving size and weight. In this work, an analytical current-force model is established for the coarse actuator considering higher order harmonic magnetic field, and based on the proposed model, the force ripple of coarse actuator is quantitatively analyzed both in theory and in practical. Furthermore, a disturbance observer is employed in the dual-feedback configuration to deal with the uncertainties with the proved asymptotic stability. The experimental results show that the proposed dual-stage positioning system is capable to achieve 20 nm step resolution with a root mean square error of 13.15 nm, and the 5 mm point-to-point positioning error can achieve less than 40 nm.
引用
收藏
页码:5553 / 5563
页数:11
相关论文
共 39 条
[1]  
[Anonymous], 2001, PERMANENT MAGNET ELE
[2]  
[Anonymous], 1997, THESIS
[3]   Multiphase Active Way Linear Motor: Proof-of-Concept Prototype [J].
Carpita, Mauro ;
Beltrami, Tazio ;
Besson, Christophe ;
Gavin, Serge .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (05) :2178-2188
[4]   A nonlinear disturbance observer for robotic manipulators [J].
Chen, WH ;
Ballance, DJ ;
Gawthrop, PJ ;
O'Reilly, J .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2000, 47 (04) :932-938
[5]   A High-Precision Dual-Servo Stage Using Halbach Linear Active Magnetic Bearings [J].
Choi, Young-Man ;
Gweon, Dae-Gab .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2011, 16 (05) :925-931
[6]   Damping and Tracking Control Schemes for Nanopositioning [J].
Eielsen, Arnfinn A. ;
Vagia, Marialena ;
Gravdahl, J. Tommy ;
Pettersen, Kristin Y. .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2014, 19 (02) :432-444
[7]   Multi-scale Alignment and Positioning System - MAPS [J].
Fesperman, Ronnie ;
Ozturk, Ozkan ;
Hocken, Robert ;
Ruben, Shalom ;
Tsao, Tsu-Chin ;
Phipps, James ;
Lemmons, Tiffany ;
Brien, John ;
Caskey, Greg .
PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2012, 36 (04) :517-537
[8]  
Fleming A.J., 2014, DESIGN MODELING CONT
[9]   Modeling maglev passenger compartment static magnetic fields from linear halbach permanent-magnet arrays [J].
Hoburg, JE .
IEEE TRANSACTIONS ON MAGNETICS, 2004, 40 (01) :59-64
[10]   Contact-Induced Vibration in Dual-Stage Hard Disk Drive Servo Systems and Its Compensator Design [J].
Huang, Deqing ;
Venkataramanan, Venkatakrishnan ;
Xu, Jian-Xin ;
The Cat Tuong Huynh .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (08) :4052-4060