Temperature characteristics of a BGO fiber-optic voltage transformer

被引:4
|
作者
Yan, Yuntao [1 ]
Wu, Chongqing [1 ]
Liu, Lanlan [1 ]
Wang, Jian [1 ]
机构
[1] Beijing Jiaotong Univ, Coll Phys, Sch Sci, Minist Educ,Key Lab Luminescence & Opt Informat T, Beijing 100044, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
10.1364/AO.58.007781
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The temperature stability of the optical fiber voltage transformer (OVT) has always been the key factor restricting its practical application. There are many factors affecting temperature characteristics, including residual birefringence during Bi4Ge3O12 (BGO) processing, the thermo-optic effect, the thermal expansion effect, and temperature change of the second-order nonlinear polarization coefficient. These complex effects interact with each other and affect the temperature characteristics of the OVT. Therefore, for a long time, the research of various literatures has not been comprehensive enough, and even has certain contradictions. In this paper, the mechanism between the five influencing factors and the OVT temperature characteristics was investigated. The experimental results show that the temperature characteristics of OVT can be divided into two aspects: the starting point and the conversion coefficient. The starting point is affected by the residual birefringence of the BGO crystal, crystal alignment, the thermal expansion of the crystal, and the thermo-optic effect. The conversion coefficient is affected by the starting point, the thermo-optic effect and the second-order nonlinear polarization coefficient. (C) 2019 Optical Society of America
引用
收藏
页码:7781 / 7788
页数:8
相关论文
共 50 条
  • [41] Wireless fiber-optic temperature sensor system
    Xing, Jie-Wen
    Zhu, Shan
    Wang, Ting-Yun
    Pang, Fu-Fei
    Chen, Na
    Chen, Zhen-Yi
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2011, 22 (05): : 693 - 696
  • [42] Biomedical Fiber-Optic Temperature and Pressure Sensors
    Korolyov, V.A.
    Potapov, V.T.
    Biomedical Engineering, 2012, 46 (02) : 79 - 82
  • [43] THE NEW FIBER-OPTIC TEMPERATURE SENSOR FOR GREENHOUSE
    Wang, Xueguang
    Liu, Zenghuan
    Du, Xiaowei
    COMPUTER AND COMPUTING TECHNOLOGIES IN AGRICULTURE II, VOLUME 3, 2009, : 2077 - 2082
  • [44] Semiconductor absorption fiber-optic temperature sensor
    Wang, T.Y.
    Luo, C.M.
    Shen, Z.
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2001, 41 (03): : 59 - 61
  • [45] Fiber-Optic SPR Sensor for Temperature Measurement
    Zhao, Yong
    Deng, Ze-Qun
    Hu, Hai-Feng
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2015, 64 (11) : 3099 - 3104
  • [46] Temperature effects in a brillouin fiber-optic gyroscope
    Wan, Shengpeng
    He, Xingdao
    Zhongguo Jiguang/Chinese Journal of Lasers, 2010, 37 (01): : 162 - 165
  • [47] A smart fiber-optic radiation temperature transducer
    Hu, HL
    Zhang, XP
    Xu, TM
    Shen, ZR
    ISTM/2001: 4TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, 2001, : 1598 - 1602
  • [48] High-temperature fiber-optic thermometry
    Kennedy, JL
    Henry, DA
    Djeu, N
    APPLICATIONS OF PHOTONIC TECHNOLOGY 5: CLOSING THE GAP BETWEEN THEORY, DEVELOPMENT, AND APPLICATION, 2002, 4833 : 116 - 120
  • [49] TEMPERATURE ERROR OF FIBER-OPTIC MEASURING SYSTEMS
    Polyakov, A. V.
    Ksenofontov, M. A.
    JOURNAL OF ENGINEERING PHYSICS AND THERMOPHYSICS, 2007, 80 (04) : 781 - 785
  • [50] Temperature compensation of fiber-optic current sensors
    Mueller, Georg M.
    Yang, Lin
    Guelenaltin, Berkan
    Frank, Andreas
    Bohnert, Klaus
    23RD INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, 2014, 9157