Three-dimensional catheter positioning during radiofrequency ablation in patients: First application of a real-time position management system

被引:0
作者
De Groot, NM [1 ]
Bootsma, M [1 ]
van der Velde, ET [1 ]
Schalij, MJ [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Cardiol, NL-2300 RC Leiden, Netherlands
关键词
radiofrequency catheter ablation; three-dimensional mapping; position management; ventricular tachycardia; supraventricular tachycardia;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Precise localization of target sites for radiofrequency catheter ablation (RFCA) of arrhythmias is hampered by the relative inaccuracy of X-ray localization procedures. This study evaluated the efficacy of a three-dimensional (3D) real-time position management system in guiding RFCA procedures in patients. Methods and Results: Patients (n = 30, age 59 +/- 20 years) referred for ablation of either atrial flutter (n = 10), ventricular tachycardia (n = 15), or accessory pathways (n = 5) were studied. The real-time position management system uses ultrasound ranging techniques to track the position of an ablation catheter relative to two multitransducer reference catheters, positioned in the right atrium or coronary sinus and the right ventricle. Each catheter contains three or four ultrasound transducers, The distance between the transducer(s) is determined by calculating the time necessary for an ultrasound pulse to reach other transducers, assuming the speed of sound in blood is 1,550 m/sec. The proximal His bundle was marked at the beginning and the end of the procedure as an electrical landmark to verify reproducibility, After identification of target sites, the position of each lesion created with the ablation catheter was marked. Successful ablation was achieved in 94% of the patients, The distance between the location of the proximal His bundle as marked at the beginning and at the end of the procedure was 2.0 +/- 1.2 mm (range 1.5 to 3.5). Conclusion: The new 3D real-time position management system facilitated RFCA procedures as it allowed accurate and reproducible 3D tracking of the mapping and ablation catheter.
引用
收藏
页码:1183 / 1192
页数:10
相关论文
共 29 条
  • [1] Nonfluoroscopic, in vivo navigation and mapping technology
    BenHaim, SA
    Osadchy, D
    Schuster, I
    Gepstein, L
    Hayam, G
    Josephson, ME
    [J]. NATURE MEDICINE, 1996, 2 (12) : 1393 - 1395
  • [2] RADIOFREQUENCY CATHETER ABLATION OF ACCESSORY ATRIOVENTRICULAR CONNECTIONS IN 250 PATIENTS - ABBREVIATED THERAPEUTIC APPROACH TO WOLFF-PARKINSON-WHITE SYNDROME
    CALKINS, H
    LANGBERG, J
    SOUSA, J
    ELATASSI, R
    LEON, A
    KOU, W
    KALBFLEISCH, S
    MORADY, F
    [J]. CIRCULATION, 1992, 85 (04) : 1337 - 1346
  • [3] Electrophysiological effects of catheter ablation of inferior vena cava-tricuspid annulus isthmus in common atrial flutter
    Cauchemez, B
    Haissaguerre, M
    Fischer, B
    Thomas, O
    Clementy, J
    Coumel, P
    [J]. CIRCULATION, 1996, 93 (02) : 284 - 294
  • [4] RADIOFREQUENCY ABLATION OF THE INFERIOR VENA-CAVA - TRICUSPID-VALVE ISTHMUS IN COMMON ATRIAL-FLUTTER
    COSIO, FG
    LOPEZGIL, M
    GOICOLEA, A
    ARRIBAS, F
    BARROSO, JL
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (08) : 705 - 709
  • [5] SIMULTANEOUS 60-ELECTRODE MAPPING OF VENTRICULAR-TACHYCARDIA USING PERCUTANEOUS CATHETERS
    DAVIS, LM
    COOPER, M
    JOHNSON, DC
    UTHER, JB
    RICHARDS, DAB
    ROSS, DL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (03) : 709 - 719
  • [6] MACROREENTRY IN THE INFARCTED HUMAN HEART - THE MECHANISM OF VENTRICULAR TACHYCARDIAS WITH A FOCAL ACTIVATION PATTERN
    DEBAKKER, JMT
    VANCAPELLE, FJL
    JANSE, MJ
    VANHEMEL, NM
    HAUER, RNW
    DEFAUW, JJAM
    VERMEULEN, FEE
    DEWEKKER, PFAB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (04) : 1005 - 1014
  • [7] ENDOCARDIAL MAPPING OF VENTRICULAR-TACHYCARDIA IN THE INTACT HUMAN VENTRICLE .3. EVIDENCE OF MULTIUSE REENTRY WITH SPONTANEOUS AND INDUCED BLOCK IN PORTIONS OF REENTRANT PATH COMPLEX
    DOWNAR, E
    SAITO, J
    DOIG, JC
    CHEN, TCK
    SEVAPTSIDIS, E
    MASSE, S
    KIMBER, S
    MICKLEBOROUGH, L
    HARRIS, L
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (07) : 1591 - 1600
  • [8] RADIOFREQUENCY CATHETER ABLATION FOR THE TREATMENT OF HUMAN TYPE-1 ATRIAL-FLUTTER - IDENTIFICATION OF A CRITICAL ZONE IN THE REENTRANT CIRCUIT BY ENDOCARDIAL MAPPING TECHNIQUES
    FELD, GK
    FLECK, RP
    CHEN, PS
    BOYCE, K
    BAHNSON, TD
    STEIN, JB
    CALISI, CM
    IBARRA, M
    [J]. CIRCULATION, 1992, 86 (04) : 1233 - 1240
  • [9] Gepstein L, 1997, CIRCULATION, V95, P1611
  • [10] Validation of a new noncontact catheter system for electroanatomic mapping of left ventricular endocardium
    Gornick, CC
    Adler, SW
    Pederson, B
    Hauck, J
    Budd, J
    Schweitzer, J
    [J]. CIRCULATION, 1999, 99 (06) : 829 - 835