Robust Sensing of Distal Pulse Waveforms on a Modified Weighing Scale for Ubiquitous Pulse Transit Time Measurement

被引:14
|
作者
Carek, Andrew M. [1 ]
Inan, Omer T. [1 ,2 ]
机构
[1] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
基金
美国国家卫生研究院;
关键词
Cardiovascular health; home monitoring; photoplethysmogram; pulse measurements; pulse transit time; BLOOD-PRESSURE; ARTERIAL STIFFNESS; VELOCITY; PHOTOPLETHYSMOGRAPHY; FORCE;
D O I
10.1109/TBCAS.2017.2683801
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The measurement of aortic pulse transit time (PTT), the time for the arterial pulse wave to travel from the carotid to the femoral artery, can provide valuable insight into cardiovascular health, specifically regarding arterial stiffness and blood pressure (BP). To measure aortic PTT, both proximal and distal arterial pulse timings are required. Recently, our group has demonstrated that the ballistocardiogram signal measured on a modified weighing scale can provide an unobtrusive, yet accurate, means of obtaining a proximal timing reference; however, there are no convenient, reliablemethods to extract the distal timing from a subject standing on themodified weighing scale. It is common to use a photoplethysmograph (PPG) attached to a toe to measure this distal pulse, but we discovered that this signal is greatly deteriorated as the subject stands on the scale. In this paper, we propose a novel method to measure the distal pulse using a custom reflective PPG array attached to the dorsum side of the foot (D-PPG). A total of 12 subjects of varying skin tones were recruited to assess the preliminary validation of this approach. Pulse measurements using the D-PPG were taken from seated and standing subjects, and the commercially available PPG were measured for facilitating comparison of timing measurements. We show that the D-PPG was the only sensor to retain the high detection rate of feasible timing values. To further test and optimize the system, various factors such as applied pressure, measurement location, and LED/photodiode configuration were tested.
引用
收藏
页码:765 / 772
页数:8
相关论文
共 50 条
  • [31] Measurement of pulse transit time using AT90S8535 microcontroller
    Foo, J. Y. A.
    Wilson, S. J.
    Williams, G. R.
    Harris, M. A.
    Cooper, D. M.
    MEASUREMENT, 2006, 39 (06) : 505 - 511
  • [32] Pulse Transit Time Measurement Using Seismocardiogram and In-Ear Acoustic Sensor
    Yang, Chenxi
    Tavassolian, Negar
    PROCEEDINGS OF 2016 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2016, : 188 - 191
  • [33] Case study of ECG signal used as a reference signal in optical pulse transit time measurement of blood flow - The effect of different electrode placements on pulse transit time
    Myllyla, Teemu S.
    Vihriala, Erkki V.
    Korhonen, Vesa O.
    Sorvoja, Hannu S. S.
    SARATOV FALL MEETING 2012: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE XIV; AND LASER PHYSICS AND PHOTONICS XIV, 2013, 8699
  • [34] Continuous Non-Invasive Blood Pressure Measurement Using Pulse Transit Time in Children and Adolescents
    Zagrada, Elena
    Krickau, Tobias
    Rascher, Wolfgang
    KLINISCHE PADIATRIE, 2019, 231 (02): : 67 - 73
  • [35] Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method
    Heiko Gesche
    Detlef Grosskurth
    Gert Küchler
    Andreas Patzak
    European Journal of Applied Physiology, 2012, 112 : 309 - 315
  • [36] Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method
    Gesche, Heiko
    Grosskurth, Detlef
    Kuechler, Gert
    Patzak, Andreas
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (01) : 309 - 315
  • [37] Continuous noninvasive Pulse Transit Time Measurement for Psycho-physiological Stress Monitoring
    Hey, Stefan
    Gharbi, Adnene
    von Haaren, Birte
    Walter, Katrin
    Koenig, Nils
    Loeffler, Simone
    INTERNATIONAL CONFERENCE ON EHEALTH, TELEMEDICINE, AND SOCIAL MEDICINE: ETELEMED 2009, PROCEEDINGS, 2009, : 113 - +
  • [38] Pulse Transit Time Measurement Using Seismocardiogram, Photoplethysmogram, and Acoustic Recordings: Evaluation and Comparison
    Yang, Chenxi
    Tavassolian, Negar
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2018, 22 (03) : 733 - 740
  • [39] Use of independent component analysis to reduce motion artifact in pulse transit time measurement
    Foo, Jong Yong Abdiel
    IEEE SIGNAL PROCESSING LETTERS, 2008, 15 : 124 - 126
  • [40] Smartphone-based Continuous Blood Pressure Measurement Using Pulse Transit Time
    Gholamhosseini, Hamid
    Meintjes, Andries
    Baig, Mirza
    Linden, Maria
    PHEALTH 2016, 2016, 224 : 84 - 89