Robust Sensing of Distal Pulse Waveforms on a Modified Weighing Scale for Ubiquitous Pulse Transit Time Measurement

被引:14
|
作者
Carek, Andrew M. [1 ]
Inan, Omer T. [1 ,2 ]
机构
[1] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
基金
美国国家卫生研究院;
关键词
Cardiovascular health; home monitoring; photoplethysmogram; pulse measurements; pulse transit time; BLOOD-PRESSURE; ARTERIAL STIFFNESS; VELOCITY; PHOTOPLETHYSMOGRAPHY; FORCE;
D O I
10.1109/TBCAS.2017.2683801
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The measurement of aortic pulse transit time (PTT), the time for the arterial pulse wave to travel from the carotid to the femoral artery, can provide valuable insight into cardiovascular health, specifically regarding arterial stiffness and blood pressure (BP). To measure aortic PTT, both proximal and distal arterial pulse timings are required. Recently, our group has demonstrated that the ballistocardiogram signal measured on a modified weighing scale can provide an unobtrusive, yet accurate, means of obtaining a proximal timing reference; however, there are no convenient, reliablemethods to extract the distal timing from a subject standing on themodified weighing scale. It is common to use a photoplethysmograph (PPG) attached to a toe to measure this distal pulse, but we discovered that this signal is greatly deteriorated as the subject stands on the scale. In this paper, we propose a novel method to measure the distal pulse using a custom reflective PPG array attached to the dorsum side of the foot (D-PPG). A total of 12 subjects of varying skin tones were recruited to assess the preliminary validation of this approach. Pulse measurements using the D-PPG were taken from seated and standing subjects, and the commercially available PPG were measured for facilitating comparison of timing measurements. We show that the D-PPG was the only sensor to retain the high detection rate of feasible timing values. To further test and optimize the system, various factors such as applied pressure, measurement location, and LED/photodiode configuration were tested.
引用
收藏
页码:765 / 772
页数:8
相关论文
共 50 条
  • [21] Considering Skin Inhomogeneity in Photoplethysmography-Based Local Pulse Transit Time Measurement
    Beckmann, Nils
    Viga, Reinhard
    Doganguen, Ayseguel
    Grabmaier, Anton
    2018 IEEE LIFE SCIENCES CONFERENCE (LSC), 2018, : 101 - 104
  • [22] A novel calibration method for noninvasive blood pressure measurement using pulse transit time
    Yan, Y. S.
    Zhang, Y. T.
    2007 4TH IEEE/EMBS INTERNATIONAL SUMMER SCHOOL AND SYMPOSIUM ON MEDICAL DEVICES AND BIOSENSORS, 2007, : 1 - +
  • [23] Pulse Transit Time Measurement Method with Artifact Tolerance for Home Healthcare
    Shiraishi, Naoto
    Sankai, Yoshiyuki
    2013 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), 2013, : 908 - 913
  • [24] Motion artefact reduction of the photoplethysmographic signal in pulse transit time measurement
    Foo J.Y.A.
    Wilson S.J.
    Williams G.R.
    Harris M.
    Cooper D.M.
    Australasian Physics & Engineering Sciences in Medicine, 2004, 27 (4): : 165 - 173
  • [25] Measurement of pulse transit time using ultra-wideband radar
    Cho, Hui-Sup
    Park, Young-Jin
    TECHNOLOGY AND HEALTH CARE, 2021, 29 (05) : 859 - 868
  • [26] Validation of a novel and existing algorithms for the estimation of pulse transit time: advancing the accuracy in pulse wave velocity measurement
    Vardoulis, Orestis
    Papaioannou, Theodore G.
    Stergiopulos, Nikolaos
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2013, 304 (11): : H1558 - H1567
  • [27] Continuous and Noninvasive Blood Pressure Estimation by Two-Sensor Measurement of Pulse Transit Time
    Rasool, Anam
    Rafiq, Muqudas
    Nasir, Aisha
    Kashif, Faisal M.
    2018 14TH INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES (ICET), 2018,
  • [28] The method for determining a pulse transit time, which is based on simultaneous measurement of ECG and PPG signals
    Sieczkowski, Krzysztof
    Dobrowolski, Andrzej Piotr
    Sondej, Tadeusz
    Olszewski, Robert
    PRZEGLAD ELEKTROTECHNICZNY, 2019, 95 (11): : 101 - 104
  • [29] Continuous blood pressure monitoring during exercise using pulse wave transit time measurement
    Lass, J
    Meigas, K
    Karai, D
    Kattai, R
    Kaik, J
    Rossmann, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 2239 - 2242
  • [30] Exploration and Validation of Alternate Sensing Methods for Wearable Continuous Pulse Transit Time Measurement Using Optical and Bioimpedance Modalities
    Ibrahim, Bassem
    Nathan, Viswam
    Jafari, Roozbeh
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 2051 - 2055