Prospective assessment of diagnostic efficacy and safety of SonazoidTM and SonoVue(R) ultrasound contrast agents in patients with focal liver lesions

被引:27
|
作者
Lv, Ke [1 ]
Zhai, Hongyan [14 ]
Jiang, Yuxin [1 ]
Liang, Ping [2 ]
Xu, Hui-Xiong [3 ]
Du, Lianfang [4 ]
Chou, Yi-Hong [5 ]
Xie, Xiaoyan [6 ]
Luo, YuKun [2 ]
Lee, Young Joon [7 ]
Lee, Jae Young [8 ]
Hu, Bing [9 ]
Luo, Baoming [10 ]
Wang, Yi [11 ]
Luan, Ying [12 ]
Kalli, Christina [12 ]
Chen, Kun [12 ]
Wang, Wenping [13 ]
Liang, Ja-Der [15 ]
机构
[1] Chinese Acad Med Sci, Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Ultrasound, Beijing 100730, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Beijing, Peoples R China
[3] Tongji Univ, Shanghai Peoples Hosp 10, Shanghai, Peoples R China
[4] Shanghai First Peoples Hosp, Shanghai, Peoples R China
[5] Taipei Vet Gen Hosp, Taipei, Peoples R China
[6] Sun Yatsen Univ, Affiliated Hosp 1, Guangzhou, Peoples R China
[7] Seoul St Marys Hosp, Seoul, South Korea
[8] Seoul Natl Univ Hosp, Seoul, South Korea
[9] Shanghai Sixth Hosp, Shanghai, Peoples R China
[10] Sun Yet Sen Univ, Sun Yet Sen Mem Hosp, Guangzhou, Peoples R China
[11] Fudan Univ, Shanghai Hua Shan Hosp, Shanghai, Peoples R China
[12] GE HealthcareLife Sci, Piscataway, NJ USA
[13] Fudan Univ, Zhongshan Hosp, Shanghai, Peoples R China
[14] Tianjin Med Univ, Gen Hosp, Tianjin, Peoples R China
[15] Natl Taiwan Univ Hosp, Taipei, Peoples R China
关键词
Contrast-enhanced ultrasound; Focal liver lesions; Characterization; Vascular imaging; Diagnostic accuracy; HEPATOCELLULAR-CARCINOMA; ENHANCED ULTRASONOGRAPHY; RADIOFREQUENCY ABLATION; NODULAR HYPERPLASIA; SONOGRAPHY; DIFFERENTIATION; MICROBUBBLES; US;
D O I
10.1007/s00261-021-03010-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To assess the respective diagnostic value of Sonazoid (TM) and SonoVue (R) for characterizing FLLs as benign or malignant and the corresponding safety. Methods This prospective Phase 3 study was conducted at 17 centres in China and Korea (May 2014 to April 2015); 424 patients (20 to 80 years) with at least 1 untreated focal liver lesion (FLL) (< 10 cm in diameter) underwent a contrast-enhanced ultrasound (CEUS) examination (218 received Sonazoid of 0.12 mu L microbubbles/kg; 206 received SonoVue of 2.4 mL). Three independent blinded readers evaluated pre- and post-contrast images characterising the FLLs as benign or malignant. Results Sonazoid-enhanced and SonoVue-enhanced ultrasound provided a statistically significant improvement in specificity for all 3 readers comparing to unenhanced ultrasound (for Sonazoid: p = 0.0093, < 0.0001, 0.0011; for SonoVue: p = 0.002, 0.03, 0.12, respectively). Difference in accuracy improvement between the 2 groups was within the pre-specified non-inferiority margin of 20% for all 3 readers (6.1%, 95% CI: - 5.0 to 17.2; - 7.5%, 95% CI: - 18.4 to 3.5; - 0.3%, 95% CI: - 11.3 to 10.7). The diagnostic confidence level for all 3 readers increased with post-contrast images relative to pre-contrast images. Both contrast agents were well tolerated. Conclusion Results showed a similar efficacy for Sonazoid (TM) and SonoVue (R) in diagnosing FLLs as benign or malignant, and underlined the benefit of CEUS imaging over unenhanced ultrasound imaging in reaching a confident diagnosis without having to refer patients for additional imaging exams.
引用
收藏
页码:4647 / 4659
页数:13
相关论文
共 44 条
  • [21] Diagnostic Performance of an Artificial Intelligence Model Based on Contrast-Enhanced Ultrasound in Patients with Liver Lesions: A Comparative Study with Clinicians
    Urhut, Marinela-Cristiana
    Sandulescu, Larisa Daniela
    Streba, Costin Teodor
    Mamuleanu, Madalin
    Ciocalteu, Adriana
    Cazacu, Sergiu Marian
    Danoiu, Suzana
    DIAGNOSTICS, 2023, 13 (21)
  • [22] Undetermined focal liver lesions on gray-scale ultrasound in patients with fatty liver: Characterization with contrast-enhanced ultrasound
    Wang, Zhi-Li
    Tang, Jie
    Weskott, Hance Peter
    Li, Jun-Lai
    Wang, Wei
    Luo, Yu-Kun
    An, Li-Chun
    Xu, Jian-Hong
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2008, 23 (10) : 1511 - 1519
  • [23] Diagnostic performance of contrast-enhanced ultrasound for complex cystic focal liver lesions: blinded reader study
    Lin, Man-Xia
    Xu, Hui-Xiong
    Lu, Ming-De
    Xie, Xiao-Yan
    Chen, Li-Da
    Xu, Zuo-Feng
    Liu, Guang-Jian
    Xie, Xiao-Hua
    Liang, Jin-Yu
    Wang, Zhu
    EUROPEAN RADIOLOGY, 2009, 19 (02) : 358 - 369
  • [24] Diagnostic performance of contrast-enhanced ultrasound for complex cystic focal liver lesions: blinded reader study
    Man-Xia Lin
    Hui-Xiong Xu
    Ming-De Lu
    Xiao-Yan Xie
    Li-Da Chen
    Zuo-Feng Xu
    Guang-Jian Liu
    Xiao-Hua Xie
    Jin-Yu Liang
    Zhu Wang
    European Radiology, 2009, 19 : 358 - 369
  • [25] Real-time contrast-enhanced ultrasound in the evaluation of focal liver lesions: diagnostic efficacy and economical issues from a French multicentric study
    Tranquart, F.
    Correas, J. M.
    Marcus, V. Ladam
    Manzoni, P.
    Vilgrain, V.
    Aube, C.
    Elmaleh, A.
    Chami, L.
    Claudon, M.
    Cuilleron, M.
    Diris, B.
    Garibaldi, F.
    Lucidarme, O.
    Marion, D.
    Beziat, C.
    Rode, A.
    Tasu, J. P.
    Trillaud, H.
    Bleuzen, A.
    Le Gouge, A.
    Giraudeau, B.
    Rusch, E.
    JOURNAL DE RADIOLOGIE, 2009, 90 (01): : 109 - 122
  • [26] A Prospective Assessment of the Diagnostic Value of Contrast-Enhanced Ultrasound, Dynamic Computed Tomography and Magnetic Resonance Imaging for Patients with Small Liver Tumors
    Hsiao, Chih-Yang
    Chen, Po-Da
    Huang, Kai-Wen
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (09)
  • [27] Contrast-enhanced Ultrasound for the Characterization of Focal Liver Lesions - Diagnostic Accuracy in Clinical Practice (DEGUM multicenter trial)
    Strobel, D.
    Seitz, K.
    Blank, W.
    Schuler, A.
    Dietrich, C.
    von Herbay, A.
    Friedrich-Rust, M.
    Kunze, G.
    Becker, D.
    Will, U.
    Kratzer, W.
    Albert, F. W.
    Pachmann, C.
    Dirks, K.
    Strunk, H.
    Greis, C.
    Bernatik, T.
    ULTRASCHALL IN DER MEDIZIN, 2008, 29 (05): : 499 - 505
  • [28] Solid focal liver lesions indeterminate by contrast-enhanced CT or MR imaging: the added diagnostic value of contrast-enhanced ultrasound
    Emilio Quaia
    Abdominal Imaging, 2012, 37 : 580 - 590
  • [29] Quantitative time intensity curve analysis of contrast-enhanced ultrasound (CEUS) examinations for the assessment of focal liver lesions
    Badiu, Maria Simona
    Gheorghe, Elena Codruta
    Nicolau, Carmen
    Saftoiu, Adrian
    MEDICAL ULTRASONOGRAPHY, 2024, 26 (01) : 63 - 71
  • [30] Contrast-enhanced ultrasound (CEUS) has excellent diagnostic accuracy in differentiating focal liver lesions: results from a Swiss tertiary gastroenterological centre
    Mikael, Sawatzki
    Christa, Meyenberger
    Stephan, Brand
    David, Semela
    SWISS MEDICAL WEEKLY, 2019, 149