In practical structural health monitoring applications, the environmental conditions typically vary over time. This variation can potentially affect the ultrasound detection of a sensor for damage detection, because ultrasound propagation as well as its coupling through adhesive bond layer to the sensor can be altered. In this case, a reference signal measured without structural defect under some initial condition may not be valid for comparison with the distorted signal (due to defect) that is measured under a different condition. In order to extract reference and distorted signals under the same condition at the same time, in this work we investigate a self-referencing ultrasound detection of fiber Bragg grating (FBG) by bonding an optical fiber at two different locations away from the FBG. We demonstrate that ultrasounds in a thin structure can couple to optical fiber guided ultrasounds through two adhesive bonds. We examine the ultrasounds trapped within the optical fiber, which are producing signal interference and beating behavior of the output FBG response. Based on understanding the ultrasound coupling mechanism through two adhesive bonds, finally we test the self-referencing ultrasound detection case, investigating the output FBG response that contains a combined signal of distorted and reference signals extracted through each bond.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Self-referencing surface plasmon sensor for resolution enhancement
    Kohandani, Reza
    Saini, Simarjeet
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [22] Fiber Bragg Grating Sensor and Waveguide Grating Sensor
    Long, Pin
    PHOTONICS NORTH 2011, 2011, 8007
  • [23] Fiber Bragg grating ultrasound sensor for process monitoring and NDE applications
    Fomitchov, PA
    Krishnaswamy, S
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 21A & B, 2002, 615 : 937 - 944
  • [24] Microstructured optical fiber Bragg grating sensor for DNA detection
    Candiani, A.
    Giannetti, S.
    Sozzi, M.
    Coscelli, E.
    Poli, F.
    Cucinotta, A.
    Bertucci, A.
    Corradini, R.
    Konstantaki, M.
    Margulis, W.
    Pissadakis, S.
    Selleri, S.
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS XIII, 2013, 8576
  • [25] Fiber Sensor Based on Interferometer and Bragg Grating for Multiparameter Detection
    Wu, Qi
    Okabe, Yoji
    Wo, Jianghai
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2015, 27 (12) : 1345 - 1348
  • [26] Fiber Bragg Grating Sensor for Hydrogen Detection in Power Transformers
    Ma, Guo-Ming
    Li, Cheng-Rong
    Mu, Rui-Duo
    Jiang, Jun
    Luo, Ying-Ting
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (01) : 380 - 385
  • [27] FRP Strain Measurement Using Self-Referencing Intensity-Based Fiber Optic Sensor
    Choi, Sang-Jin
    Kim, Young-Chon
    Song, Minho
    Pan, Jae-Kyung
    2014 International Conference on Electronics, Information and Communications (ICEIC), 2014,
  • [28] Fiber Bragg grating sensor for petroleum hydrocarbon leak detection
    Spirin, VV
    Shlyagin, MG
    Miridonov, SV
    Jiménez, FJM
    Gutiérrez, RML
    OPTICS AND LASERS IN ENGINEERING, 1999, 32 (05) : 497 - 503
  • [29] An Innovative Self-Adhesive Wearable Sensor Based on Fiber Bragg Grating Technology for Plant Growth Monitoring
    Condo, I.
    Pizziconi, B.
    Cimini, S.
    Trombetta, M.
    De Gara, L.
    Schena, E.
    Giannitelli, S. M.
    Lo Presti, D.
    IEEE SENSORS JOURNAL, 2025, 25 (02) : 2705 - 2713
  • [30] Self-referencing resonant fiber optic intensity sensor based on a Mach-Zehnder topology
    Baptista, JM
    Cavaleiro, PM
    Santos, JL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (11): : 3788 - 3794