A LUMPED PARAMETER MODEL OF CARDIOVASCULAR SYSTEM WITH PULSATING HEART FOR DIAGNOSTIC STUDIES

被引:13
|
作者
Frolov, S. V. [1 ]
Sindeev, S. V. [1 ]
Lischouk, V. A. [2 ]
Gazizova, D. Sh. [2 ]
Liepsch, D. [3 ]
Balasso, A. [4 ]
机构
[1] Tambov State Tech Univ, Dept Biomed Engn, Sovetskaya St 106, Tambov, Russia
[2] Bakoulev Ctr Cardiovasc Surg, Lab Math Modeling & Monitoring, Roublyevskoe Shosse 135, Moscow, Russia
[3] Munich Univ Appl Sci, Dept Bldg Serv Engn Paper & Packaging Technol & P, Lothstr 34, Munich, Germany
[4] Tech Univ Munich, Dept Neuroradiol, Klinikum Rechts Isar, Ismaninger Str 22, Munich, Germany
关键词
Cardiac modeling; patient-specific simulation; model of global hemodynamics; lumped parameter model; IN-VITRO; SIMULATION; VALIDATION;
D O I
10.1142/S0219519417500567
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Mathematical modeling of cardiovascular system provides an ability to study hemodynamics and to predict the results of treatment based on individual anatomical and physiological data of patients. However, the presently developed models of cardiovascular system have a limitation on use in clinical practice due to their physical and computational complexities. The aim of this study is to derive a lumped parameter model of cardiovascular system with pulsating heart in which all parameters have a physically based quantitative value and can be identified using clinical methods. For development of a cardiovascular system model the chamber analog was used which describes whole cardiovascular system as a set of elastic chambers. The proposed model consists of systemic and pulmonary circulation, four-chamber heart and four valves. The description of heart is based on a four-element representation of a cardiac muscle. The reverse blood flow via valves is considered. The accuracy of the derived model was evaluated by comparing the data of numerical simulation with experimental data. The limitations of the model were discussed as well as possible applications of the model were suggested. The proposed lumped parameter model can be used to support clinicians in their decisions in treating cardiovascular disorders.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] A lumped parameter mathematical model to analyze the effects of tachycardia and bradycardia on the cardiovascular system
    Abdi, Mohsen
    Karimi, Alireza
    Navidbakhsh, Mahdi
    Jahromi, Gila Pirzad
    Hassani, Kamran
    INTERNATIONAL JOURNAL OF NUMERICAL MODELLING-ELECTRONIC NETWORKS DEVICES AND FIELDS, 2015, 28 (03) : 346 - 357
  • [2] A closed-loop lumped parameter computational model for human cardiovascular system
    Liang, FY
    Liu, H
    JSME INTERNATIONAL JOURNAL SERIES C-MECHANICAL SYSTEMS MACHINE ELEMENTS AND MANUFACTURING, 2005, 48 (04) : 484 - 493
  • [3] Lumped parameter heart model with valve dynamics
    Simakov, Sergey S.
    RUSSIAN JOURNAL OF NUMERICAL ANALYSIS AND MATHEMATICAL MODELLING, 2019, 34 (05) : 289 - 300
  • [4] Lumped Parameter Model of Cardiovascular-Respiratory Interaction
    Gaudenzi, Fabrizio
    Avolio, Alberto P.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 473 - 476
  • [5] A LUMPED PARAMETER MODEL OF CEREBROSPINAL FLUID SYSTEM
    AGARWAL, GC
    BERMAN, BM
    STARK, L
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1969, BM16 (01) : 45 - &
  • [6] A female-specific cardiovascular lumped-parameter model
    Comunale, Giulia
    Susin, Francesca M.
    Mynard, Jonathan P.
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 2654 - 2657
  • [7] WAVE DISPERSION ANALYSIS OF PULSATING FLOWS IN A CIRCULAR CONDUIT USING A LUMPED PARAMETER MODEL
    Chun, Sejong
    Jin, Jonghan
    PROCEEDINGS OF THE ASME/JSME/KSME JOINT FLUIDS ENGINEERING CONFERENCE, 2015, VOL 2A: FORA, PT 2, 2016,
  • [8] A Lumped-Parameter Model of the Cardiovascular System Response for Evaluating Automated Fluid Resuscitation Systems
    Chalumuri, Yekanth Ram
    Arabidarrehdor, Ghazal
    Tivay, Ali
    Sampson, Catherine M.
    Khan, Muzna
    Kinsky, Michael
    Kramer, George C.
    Hahn, Jin-Oh
    Scully, Christopher G.
    Bighamian, Ramin
    IEEE ACCESS, 2024, 12 : 62511 - 62525
  • [9] Lumped parameter model for hemodynamic simulation of congenital heart diseases
    Shuji Shimizu
    Dai Une
    Toru Kawada
    Yohsuke Hayama
    Atsunori Kamiya
    Toshiaki Shishido
    Masaru Sugimachi
    The Journal of Physiological Sciences, 2018, 68 : 103 - 111
  • [10] Lumped parameter model for hemodynamic simulation of congenital heart diseases
    Shimizu, Shuji
    Une, Dai
    Kawada, Toru
    Hayama, Yohsuke
    Kamiya, Atsunori
    Shishido, Toshiaki
    Sugimachi, Masaru
    JOURNAL OF PHYSIOLOGICAL SCIENCES, 2018, 68 (02): : 103 - 111