Unilateral versus bilateral pedicle screw fixation in lumbar spinal fusion

被引:179
|
作者
Suk, KS
Lee, HM
Kim, NH
Ha, JW
机构
[1] Yonsei Univ, Coll Med, Dept Orthopaed Surg, Seoul, South Korea
[2] Kyung Hee Univ, Sch Med, Dept Orthopaed Surg, Seoul, South Korea
[3] NIHC Ilsan Hosp, Dept Orthopaed Surg, Ilsan, South Korea
关键词
bilateral; pedicle screw fixation; unilateral;
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A prospective study of 87 patients who underwent unilateral or bilateral pedicle screw fixation. Objectives. To determine whether unilateral pedicle screw fixation is comparable with bilateral fixation in one-or two-segment lumbar spinal fusion. Summary of Background Data. Clinical results for unilateral variable screw placement instrumentation in isolated L4-L5 fusion have been reported to be as good as those for bilateral instrumentation. However, unilateral instrumentation may not be recommended for multilevel fusion. Methods. Eighty-seven patients were assigned to either unilateral (n = 47) or bilateral (n = 40) pedicle screw instrumentation groups. Two kinds of pedicle screw system (Moss Miami, DePuy, Warsaw, IN, and Steffee VSP, AcroMed, Cleveland, OH) were used. Operating time, blood loss, duration of hospital stay, clinical outcomes, fusion rates, complication rates, and medical expenses were studied and tested with independent sample t test and chi(2) test. Results. There were no significant differences between the two groups in blood loss, clinically satisfactory results, fusion rate, and complication rate. There were significant differences in duration of operating time, duration of hospital stay, and medical expenses. The number of fusion segments or kinds of instrumentation did not affect the fusion rate or clinical outcomes. Conclusions. Unilateral pedicle screw fixation was as effective as bilateral pedicle screw fixation in lumbar spinal fusion independent of the number of fusion segments (one or two segments) or pedicle screw systems. Based on the results of this study, unilateral fixation could be used in two-segment lumbar spinal fusion.
引用
收藏
页码:1843 / 1847
页数:5
相关论文
共 50 条
  • [31] Biomechanical Stability Before and After Graft Fusion with Unilateral and Bilateral Pedicle Screw Fixation: Finite Element Study
    Li, Jie
    Wang, Wenkai
    Zuo, Rui
    Zhou, Yue
    WORLD NEUROSURGERY, 2019, 123 : E228 - E234
  • [32] The comparison study of laminectomy with unilateral and bilateral pedicle screws fixation and laminectomy alone without fusion interbody in young patients with lumbar spinal stenosis: A randomized clinical trial
    Hajilo, Parisa
    Imani, Behzad
    Zandi, Shirdel
    Mehrafshan, Ali
    Khazaei, Salman
    HELIYON, 2024, 10 (15)
  • [33] Bilateral pedicle screw fixation provides superior biomechanical stability in transforaminal lumbar interbody fusion: a finite element study
    Ambati, Divya V.
    Wright, Edward K., Jr.
    Lehman, Ronald A., Jr.
    Kang, Daniel G.
    Wagner, Scott C.
    Dmitriev, Anton E.
    SPINE JOURNAL, 2015, 15 (08): : 1812 - 1822
  • [34] Minimally invasive transforaminal lumbar interbody fusion with ipsilateral pedicle screw and contralateral facet screw fixation
    Jang, JS
    Lee, SH
    JOURNAL OF NEUROSURGERY-SPINE, 2005, 3 (03) : 218 - 223
  • [35] An analysis of fusion cage migration in unilateral and bilateral fixation with transforaminal lumbar interbody fusion
    Duncan, Jan William
    Bailey, Richard Anthony
    EUROPEAN SPINE JOURNAL, 2013, 22 (02) : 439 - 445
  • [36] Comparison between posterolateral fusion with pedicle screw fixation and anterior interbody fusion with pedicle screw fixation in adult spondylolytic spondylolisthesis
    Suk, KS
    Jeon, CH
    Park, MS
    Moon, SH
    Kim, NH
    Lee, HM
    YONSEI MEDICAL JOURNAL, 2001, 42 (03) : 316 - 323
  • [37] Comparison of the clinical efficacy of unilateral and bilateral pedicle screw short-segment fixation and fusion in the treatment of atlantoaxial fracture-dislocation
    Ma, Zhuo
    Zhang, Yan-Nan
    Ma, Xun
    Chen, Chen
    Feng, Hao-Yu
    TECHNOLOGY AND HEALTH CARE, 2023, 31 (05) : 1619 - 1629
  • [38] Comparison of lumbar interbody fusion techniques using ray threaded fusion cages and pedicle screw fixation systems
    Klara, PM
    Freidank, SA
    Rezaiamiri, S
    NEUROSURGERY QUARTERLY, 2003, 13 (01) : 20 - 29
  • [39] Biomechanical comparison of unilateral and bilateral pedicle screws fixation for transforaminal lumbar interbody fusion after decompressive surgery - a finite element analysis
    Chen, Shih-Hao
    Lin, Shang-Chih
    Tsai, Wen-Chi
    Wang, Chih-Wei
    Chao, Shih-Heng
    BMC MUSCULOSKELETAL DISORDERS, 2012, 13
  • [40] Biomechanical comparison of unilateral and bilateral pedicle screws fixation for transforaminal lumbar interbody fusion after decompressive surgery -- a finite element analysis
    Shih-Hao Chen
    Shang-Chih Lin
    Wen-Chi Tsai
    Chih-Wei Wang
    Shih-Heng Chao
    BMC Musculoskeletal Disorders, 13