Fisher Information-Based Evaluation of Image Quality for Time-of-Flight PET

被引:26
|
作者
Vunckx, Kathleen [1 ]
Zhou, Lin [1 ]
Matej, Samuel [2 ]
Defrise, Michel [3 ]
Nuyts, Johan [1 ]
机构
[1] Katholieke Univ Leuven, Dept Nucl Med, B-3000 Louvain, Belgium
[2] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[3] VU Brussels, Dept Nucl Med, B-1090 Brussels, Belgium
基金
美国国家卫生研究院;
关键词
Filtered backprojection (FBP); Fisher information; image quality; maximum likelihood expectation maximization (MLEM); time-of-flight information in positron emission tomography (TOF PET); EMISSION-TOMOGRAPHY; EM ALGORITHM; RECONSTRUCTION; LIKELIHOOD; RESOLUTION; VARIANCE; BENEFIT;
D O I
10.1109/TMI.2009.2029098
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The use of time-of-flight (TOF) information during positron emission tomography (PET) reconstruction has been found to improve the image quality. In this work we quantified this improvement using two existing methods: 1) a very simple analytical expression only valid for a central point in a large uniform disk source and 2) efficient analytical approximations for postfiltered maximum likelihood expectation maximization (MLEM) reconstruction with a fixed target resolution, predicting the image quality in a pixel or in a small region of interest based on the Fisher information matrix. Using this latter method the weighting function for filtered backprojection reconstruction of TOF PET data proposed by C. Watson can be derived. The image quality was investigated at different locations in various software phantoms. Simplified as well as realistic phantoms, measured both with TOF PET systems and with a conventional PET system, were simulated. Since the time resolution of the system is not always accurately known, the effect on the image quality of using an inaccurate kernel during reconstruction was also examined with the Fisher information-based method. First, we confirmed with this method that the variance improvement in the center of a large uniform disk source is proportional to the disk diameter and inversely proportional to the time resolution. Next, image quality improvement was observed in all pixels, but in eccentric and high-count regions the contrast-to-noise ratio (CNR) increased less than in central and low- or medium-count regions. Finally, the CNR was seen to decrease when the time resolution was inaccurately modeled (too narrow or too wide) during reconstruction. Although the maximum CNR is not very sensitive to the time resolution error, using an inaccurate TOF kernel tends to introduce artifacts in the reconstructed image.
引用
收藏
页码:311 / 321
页数:11
相关论文
共 50 条
  • [41] Clinical evaluation of whole-body oncologic PET with time-of-flight and point-spread function for the hybrid PET/MR system
    Shang, Kun
    Cui, Bixiao
    Ma, Jie
    Shuai, Dongmei
    Liang, Zhigang
    Jansen, Floris
    Zhou, Yun
    Lu, Jie
    Zhao, Guoguang
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 93 : 70 - 75
  • [42] Comparison of Image Signal-to-noise Ratio and Noise Equivalent Counts in Time-of-flight PET
    Clementel, Enrico
    Vandenberghe, Stefaan
    Karp, Joel S.
    Surti, Suleman
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3622 - 3625
  • [43] Optimized Weighting for Fourier Rebinning of Three-Dimensional Time-of-Flight PET Data to Non-Time-of-Flight
    Ahn, Sangtae
    Cho, Sanghee
    Li, Quanzheng
    Leahy, Richard M.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2989 - 2996
  • [44] Improvement in Lesion Detection with Whole-Body Oncologic Time-of-Flight PET
    El Fakhri, Georges
    Surti, Suleman
    Trott, Cathryn M.
    Scheuermann, Joshua
    Karp, Joel S.
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (03) : 347 - 353
  • [45] Timing Performance Study of New Fast PMTs With LYSO for Time-of-Flight PET
    Ito, Mikiko
    Lee, Jin Pyo
    Lee, Jae Sung
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (01) : 30 - 37
  • [46] Timing Performance Evaluation of PMT-Quadrant-Sharing LYSO Detectors for Time-of-Flight PET
    An, Shaohui
    Li, Hongdi
    Liu, Shitao
    Ramirez, Rocio
    Zhang, Yuxuan
    Wang, Chao
    Baghaei, Hossain
    Wong, Wai-Hoi
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (05) : 2155 - 2160
  • [47] High-performance electronics for time-of-flight PET systems
    Choong, W. -S.
    Peng, Q.
    Vu, C. Q.
    Turko, B. T.
    Moses, W. W.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [48] Quantitative Accuracy of Time-of-Flight PET at High Count Rates
    Daube-Witherspoon, Margaret E.
    Scheuermann, Joshua
    Viswanath, Varsha
    Surti, Suleman
    Matej, Samuel
    Karp, Joel S.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [49] An Improved Weighting Kernel for Analytical Time-of-Flight PET Reconstruction
    Watson, Charles C.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (05) : 2551 - 2556
  • [50] Improved Intrinsic Motion Detection Using Time-of-Flight PET
    Xu, Jingyan
    Tsui, Benjamin M. W.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (10) : 2131 - 2145