Fisher Information-Based Evaluation of Image Quality for Time-of-Flight PET

被引:26
|
作者
Vunckx, Kathleen [1 ]
Zhou, Lin [1 ]
Matej, Samuel [2 ]
Defrise, Michel [3 ]
Nuyts, Johan [1 ]
机构
[1] Katholieke Univ Leuven, Dept Nucl Med, B-3000 Louvain, Belgium
[2] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[3] VU Brussels, Dept Nucl Med, B-1090 Brussels, Belgium
基金
美国国家卫生研究院;
关键词
Filtered backprojection (FBP); Fisher information; image quality; maximum likelihood expectation maximization (MLEM); time-of-flight information in positron emission tomography (TOF PET); EMISSION-TOMOGRAPHY; EM ALGORITHM; RECONSTRUCTION; LIKELIHOOD; RESOLUTION; VARIANCE; BENEFIT;
D O I
10.1109/TMI.2009.2029098
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The use of time-of-flight (TOF) information during positron emission tomography (PET) reconstruction has been found to improve the image quality. In this work we quantified this improvement using two existing methods: 1) a very simple analytical expression only valid for a central point in a large uniform disk source and 2) efficient analytical approximations for postfiltered maximum likelihood expectation maximization (MLEM) reconstruction with a fixed target resolution, predicting the image quality in a pixel or in a small region of interest based on the Fisher information matrix. Using this latter method the weighting function for filtered backprojection reconstruction of TOF PET data proposed by C. Watson can be derived. The image quality was investigated at different locations in various software phantoms. Simplified as well as realistic phantoms, measured both with TOF PET systems and with a conventional PET system, were simulated. Since the time resolution of the system is not always accurately known, the effect on the image quality of using an inaccurate kernel during reconstruction was also examined with the Fisher information-based method. First, we confirmed with this method that the variance improvement in the center of a large uniform disk source is proportional to the disk diameter and inversely proportional to the time resolution. Next, image quality improvement was observed in all pixels, but in eccentric and high-count regions the contrast-to-noise ratio (CNR) increased less than in central and low- or medium-count regions. Finally, the CNR was seen to decrease when the time resolution was inaccurately modeled (too narrow or too wide) during reconstruction. Although the maximum CNR is not very sensitive to the time resolution error, using an inaccurate TOF kernel tends to introduce artifacts in the reconstructed image.
引用
收藏
页码:311 / 321
页数:11
相关论文
共 50 条
  • [21] Update on Time-of-Flight PET Imaging
    Surti, Suleman
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (01) : 98 - 105
  • [22] Experimental evaluation of a simple lesion detection task with time-of-flight PET
    Surti, S.
    Karp, J. S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (02) : 373 - 384
  • [23] Improvements in PET Image Quality in Time of Flight (TOF) Simultaneous PET/MRI
    Minamimoto, Ryogo
    Levin, Craig
    Jamali, Mehran
    Holley, Dawn
    Barkhodari, Amir
    Zaharchuk, Greg
    Iagaru, Andrei
    MOLECULAR IMAGING AND BIOLOGY, 2016, 18 (05) : 776 - 781
  • [24] Improvements in PET Image Quality in Time of Flight (TOF) Simultaneous PET/MRI
    Ryogo Minamimoto
    Craig Levin
    Mehran Jamali
    Dawn Holley
    Amir Barkhodari
    Greg Zaharchuk
    Andrei Iagaru
    Molecular Imaging and Biology, 2016, 18 : 776 - 781
  • [25] An Assessment of the Impact of Incorporating Time-of-Flight Information into Clinical PET/CT Imaging
    Lois, Cristina
    Jakoby, Bjoern W.
    Long, Misty J.
    Hubner, Karl F.
    Barker, David W.
    Casey, Michael E.
    Conti, Maurizio
    Panin, Vladimir Y.
    Kadrmas, Dan J.
    Townsend, David W.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (02) : 237 - 245
  • [26] Deep learning–based time-of-flight (ToF) image enhancement of non-ToF PET scans
    Abolfazl Mehranian
    Scott D. Wollenweber
    Matthew D. Walker
    Kevin M. Bradley
    Patrick A. Fielding
    Martin Huellner
    Fotis Kotasidis
    Kuan-Hao Su
    Robert Johnsen
    Floris P. Jansen
    Daniel R. McGowan
    European Journal of Nuclear Medicine and Molecular Imaging, 2022, 49 : 3740 - 3749
  • [27] A Fisher Information-Based Incompatibility Criterion for Quantum Channels
    Zhang, Qing-Hua
    Nechita, Ion
    ENTROPY, 2022, 24 (06)
  • [28] Improvement in PET/CT Image Quality with a Combination of Point-Spread Function and Time-of-Flight in Relation to Reconstruction Parameters
    Akamatsu, Go
    Ishikawa, Kaori
    Mitsumoto, Katsuhiko
    Taniguchi, Takafumi
    Ohya, Nobuyoshi
    Baba, Shingo
    Abe, Koichiro
    Sasaki, Masayuki
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (11) : 1716 - 1722
  • [29] Detection performance analysis for time-of-flight PET
    Cao, Nannan
    Huesman, Ronald H.
    Moses, William W.
    Qi, Jinyi
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (22) : 6931 - 6950
  • [30] Noise propagation for iterative penalized-likelihood image reconstruction based on Fisher information
    Li, Yusheng
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (04) : 1083 - 1103