Are stentless valves hemodynamically superior to stented valves? Long-term follow-up of a randomized trial comparing Carpentier-Edwards pericardial valve with the Toronto Stentless Porcine Valve

被引:39
作者
Cohen, Gideon [1 ]
Zagorski, Brandon [1 ]
Christakis, George T. [1 ]
Joyner, Campbell D. [1 ]
Vincent, Jessica [1 ]
Sever, Jeri [1 ]
Harbi, Sumaya [1 ]
Feder-Elituv, Randi [1 ]
Moussa, Fuad [1 ]
Goldman, Bernard S. [1 ]
Fremes, Stephen E. [1 ]
机构
[1] Univ Toronto, Sunnybrook Hlth Sci Ctr, Div Cardiovasc Surg, Toronto, ON M4N 3M5, Canada
关键词
LEFT-VENTRICULAR HYPERTROPHY; AORTIC-VALVE; NATRIURETIC PEPTIDE; CORONARY FLOW; REPLACEMENT; BIOPROSTHESES; MORTALITY; STENOSIS; SURVIVAL; IMPACT;
D O I
10.1016/j.jtcvs.2009.04.067
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The benefit of stentless valves remains in question. In 1999, a randomized trial comparing stentless and stented valves was unable to demonstrate any hemodynamic or clinical benefits at 1 year after implantation. This study reviews long-term outcomes of patients randomized in the aforementioned trial. Methods: Between 1996 and 1999, 99 patients undergoing aortic valve replacement were randomized to receive either a stented Carpentier-Edwards pericardial valve (CE) (Edwards Lifesciences, Irvine, Calif) or a Toronto Stentless Porcine Valve (SPV) (St Jude Medical, Minneapolis, Minn). Among these, 38 patients were available for late echocardiographic follow-up (CE, n = 17; SPV, n = 21). Echocardiographic analysis was undertaken both at rest and with dobutamine stress, and functional status (Duke Activity Status Index) was compared at a mean of 9.3 years postoperatively (range, 7.5-11.1 years). Clinical follow-up was 82% complete at a mean of 10.3 years postoperatively (range, 7.5-12.2 years). Results: Preoperative characteristics were similar between groups. Effective orifice areas increased in both groups over time. Although there were no differences in effective orifice areas at 1 year, at 9 years, effective orifice areas were significantly greater in the SPV group (CE, 1.49 +/- 0.59 cm(2); SPV, 2.00 +/- 0.53 cm(2); P = .011). Similarly, mean and peak gradients decreased in both groups over time; however, at 9 years, gradients were lower in the SPV group (mean: CE, 10.8 +/- 3.8 mm Hg; SPV, 7.8 +/- 4.8 mm Hg; P = .011; peak: CE, 20.4 +/- 6.5 mm Hg; SPV, 14.6 +/- 7.1 mm Hg; P = .022). Such differences were magnified with dobutamine stress (mean: CE, 22.7 +/- 6.1 mm Hg; SPV, 15.3 +/- 8.4 mm Hg; P = .008; peak: CE, 48.1 +/- 11.8 mm Hg; SPV, 30.8 +/- 17.7 mm Hg; P = .001). Ventricular mass regression occurred in both groups; however, no differences were demonstrated between groups either on echocardiographic, magnetic resonance imaging, or biochemical (plasma B-type [brain] natriuretic peptide) assessment (P = .74). Similarly, Duke Activity Status Index scores of functional status improved in both groups over time; however, no differences were noted between groups (CE, 27.5 +/- 19.1; SPV, 19.9 +/- 12.0; P = .69). Freedom from reoperation at 12 years was 92% +/- 5% in patients with CEs and 75% +/- 5% in patients with SPVs (P = .65). Freedom from valve-related morbidity at 12 years was 82% +/- 7% in patients with CEs and 55% +/- 7% in patients with SPVs (P = .05). Finally, 12-year actuarial survival was 35% +/- 7% in patients with CEs and 52% +/- 7% in patients with SPVs (P = .37). Conclusion: Although offering improved hemodynamic outcomes, the SPV did not afford superior mass regression or improved clinical outcomes up to 12 years after implantation. (J Thorac Cardiovasc Surg 2010; 139: 848-59)
引用
收藏
页码:848 / 859
页数:12
相关论文
共 55 条
[1]   Guidelines for reporting mortality and morbidity after cardiac valve interventions [J].
Akins, Cary W. ;
Miller, D. Craig ;
Turina, Marko I. ;
Kouchoukos, Nicholas T. ;
Blackstone, Eugene H. ;
Grunkemeier, Gary L. ;
Takkenberg, Johanna J. M. ;
David, Tirone E. ;
Butchart, Eric G. ;
Adams, David H. ;
Shahian, David M. ;
Hagl, Siegfried ;
Mayer, John E. ;
Lytle, Bruce W. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 135 (04) :732-738
[2]   Early clinical and hemodynamic outcomes after stented and stentless aortic valve replacement: Results from a randomized controlled trial [J].
Ali, Ayyaz ;
Halstead, James C. ;
Cafferty, Fay ;
Sharples, Linda ;
Rose, Fiona ;
Lee, Evelyn ;
Rusk, Rosemary ;
Dunning, John ;
Argano, Vincenzo ;
Tsui, Steven .
ANNALS OF THORACIC SURGERY, 2007, 83 (06) :2162-2168
[3]   B-type natriuretic peptide is related to left ventricular mass in hypertensive patients but not in athletes [J].
Almeida, SS ;
Azevedo, A ;
Castro, A ;
Frioes, F ;
Freitas, J ;
Ferreira, A ;
Bettencourt, P .
CARDIOLOGY, 2002, 98 (03) :113-115
[4]  
Auriemma S, 2006, J HEART VALVE DIS, V15, P691
[5]  
Bach DS, 2004, J HEART VALVE DIS, V13, P64
[6]   Impact of implant technique following freestyle stentless aortic valve replacement [J].
Bach, DS ;
Cartier, PC ;
Kon, ND ;
Johnson, KG ;
Deeb, GM ;
Doty, DB .
ANNALS OF THORACIC SURGERY, 2002, 74 (04) :1107-1113
[7]   Stentless bioprostheses improve postoperative coronary flow more than stented prostheses after valve replacement for aortic stenosis [J].
Bakhtiary, F ;
Schiemann, M ;
Dzemali, O ;
Wittlinger, T ;
Doss, M ;
Ackermann, H ;
Moritz, A ;
Kleine, P .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 131 (04) :883-888
[8]   Impact of patient-prosthesis mismatch and aortic valve design on coronary flow reserve after aortic valve replacement [J].
Bakhtiary, Farhad ;
Schiemann, Mirko ;
Dzemali, Omer ;
Dogan, Selami ;
Schaechinger, Volker ;
Ackermann, Hans ;
Moritz, Anton ;
Kleine, Peter .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (07) :790-796
[9]   B-Type natriuretic peptide in low-flow, low-gradient aortic stenosis - Relationship to hemodynamics and clinical outcome: Results from the multicenter truly or pseudo-severe aortic stenosis (TOPAS) study [J].
Bergler-Klein, Jutta ;
Mundigler, Gerald ;
Pibarot, Philippe ;
Burwash, Ian G. ;
Dumesnil, Jean G. ;
Blais, Claudia ;
Fuchs, Christina ;
Mohty, Dania ;
Beanlands, Rob S. ;
Hachicha, Zeineb ;
Walter-Publig, Nicole ;
Rader, Florian ;
Baumgartner, Helmut .
CIRCULATION, 2007, 115 (22) :2848-2855
[10]   MYOCARDIAL TAGGING IN POLAR COORDINATES WITH USE OF STRIPED TAGS [J].
BOLSTER, BD ;
MCVEIGH, ER ;
ZERHOUNI, EA .
RADIOLOGY, 1990, 177 (03) :769-772