Optimization of Reflectron for Kinetic and Mechanistic Studies with Multiplexed Multiple Tandem (MSn) Time-of-flight Mass Spectrometry

被引:24
作者
Bae, Yong Jin [1 ]
Yoon, So Hee [1 ]
Moon, Jeong Hee [2 ]
Kim, Myung Soo [1 ]
机构
[1] Seoul Natl Univ, Dept Chem, Seoul 151742, South Korea
[2] KRIBB, Med Prote Res Ctr, Taejon 305806, South Korea
来源
BULLETIN OF THE KOREAN CHEMICAL SOCIETY | 2010年 / 31卷 / 01期
关键词
Tandern TOF; MSn; LPQ reflectron; Peptide photodissociation; Dissociation kinetics and dynamics; LASER-DESORPTION IONIZATION; POST-SOURCE DECAY; PROTONATED PEPTIDES; MALDI; IONS; PHOTODISSOCIATION; DISSOCIATION; CONSTRUCTION; TEMPERATURE;
D O I
10.5012/bkcs.2010.31.01.092
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Photoexcitation of a precursor ion inside a cell floated at high voltage installed in a tandem, time-or-flight (TOF) mass spectrometer provides triple tandem mass spectrometric information and allows kinetic and mechanistic Studies. IN this work, the factors affecting, or downgrading, the performance of the technique were identified. Ion-optical and computational analyses showed that all optimum Instrument could be designed by utilizing a reflectron with linear-plus-quadratic potential inside. Theoretical predictions were confirmed by tests with instruments built with different ion-optical layout. With optimized instruments,, masses of intermediate ions in the consecutive dissociation of a precursor ion Could be determined with the maximum error of 5 Da. We also observed excellent agreement in dynamical parameters (critical energy and entropy) Cur the dissociation of a model peptide ion determined by instruments with different ion-optical layout operated under optimum conditions. This suggests that these parameters call be determined reliably by the kinetic method developed previously When properly designed and operated tandem TOF instruments are used.
引用
收藏
页码:92 / 99
页数:8
相关论文
共 26 条
  • [1] Ambihapathy K, 1997, J MASS SPECTROM, V32, P209, DOI 10.1002/(SICI)1096-9888(199702)32:2<209::AID-JMS466>3.3.CO
  • [2] 2-3
  • [3] Statistical Rice-Ramsperger-Kassel-Marcus quasiequilibrium theory calculations in mass spectrometry
    Baer, T
    Mayer, PM
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (02) : 103 - 115
  • [4] SEQUENTIAL MASS-SPECTROMETRY APPLIED TO THE STUDY OF THE FORMATION OF INTERNAL FRAGMENT IONS OF PROTONATED PEPTIDES
    BALLARD, KD
    GASKELL, SJ
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 111 : 173 - 189
  • [5] Tandem time-of-flight mass spectrometry with a curved field reflectron
    Cotter, RJ
    Gardner, BD
    Iltchenko, S
    English, RD
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (07) : 1976 - 1981
  • [6] COTTER RJ, 1997, TIME OF FLIGHT MASS, P48
  • [7] Dahl D., 2000, SIMION 3D VERSION 7
  • [8] The desorption process in MALDI
    Dreisewerd, K
    [J]. CHEMICAL REVIEWS, 2003, 103 (02) : 395 - 425
  • [9] Optimization of sample preparation for peptide sequencing by MALDI-TOF photofragment mass spectrometry
    Hettick, JM
    McCurdy, DL
    Barbacci, DC
    Russell, DH
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (22) : 5378 - 5386
  • [10] Hillenkamp F., 2007, MALDI MS PRACTICAL G, P1, DOI DOI 10.1002/9783527610464.CH1