Diplopia in orbital fractures:: a simple method to evaluate eye motility

被引:5
作者
Folkestad, Lena [1 ]
Lindgren, Gun
Moller, Claes
Granstrom, Gosta
机构
[1] Univ Gothenburg, Sahlgrenska Acad, Dept Otolaryngol Head & Neck Surg, Gothenburg, Sweden
[2] Univ Gothenburg, Sahlgrenska Acad, Dept Ophthalmol, Gothenburg, Sweden
[3] Univ Gothenburg, Sahlgrenska Acad, Dept Audiol, Gothenburg, Sweden
关键词
blow-out fracture; entrapment; restricted eye motility; diplopia; ENG; vertical electro-oculography;
D O I
10.1080/00016480600750000
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Conclusion. This study on eye motility demonstrates a new application of electro-oculography which proved to have a high potential for establishing and diagnosing the cause of diplopia in orbital floor fractures. Electro-oculography is objective and easy to perform even when the restricted eye is covered. The 'uninjured' eye can be used as the reference. Any motility difference between the left and the right eye was easily detected. Objective. It is essential in orbital floor fractures to distinguish entrapment from other causes of diplopia. We investigated whether vertical eye motility and restricted elevation can be detected and characterized by means of electro-oculography. Materials and methods. Electronystagniography equipment used for vestibular testing in daily ENT practice was used in a different context. Unilateral mechanical restriction was generated in the test subjects through fixation of one eye bulb. The velocity and range of eye motility of both eyes were measured and compared in 12 healthy test subjects and 7 patients with long-term vertical diplopia after orbital floor fractures. Results. Simulated entrapment was easily detected as a distinct difference between right and left eye motility recordings (p < 0.001). Recordings of patients with diplopia differed significantly from those of healthy test subjects with respect to velocity (p < 0.05) and range of motility (p < 0.05).
引用
收藏
页码:156 / 166
页数:11
相关论文
共 23 条
[1]  
al-Hinnawi M F, 1991, Proc Inst Mech Eng H, V205, P101, DOI 10.1243/PIME_PROC_1991_205_275_02
[2]  
BRADLEY JV, 1968, DISTRIBUTION FREE ST, P68
[3]  
Burnstine Michael A, 2003, Curr Opin Ophthalmol, V14, P236, DOI 10.1097/00055735-200310000-00002
[4]  
Chamberlain J., 1997, Health Technol Assess, V1, P1
[5]   Recovery from orbital floor fractures:: a prospective study of patients' and doctors' experiences [J].
Folkestad, L ;
Åberg-Bengtsson, L ;
Granström, G .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 35 (06) :499-505
[6]   A prospective study of orbital fracture sequelae after change of surgical routines [J].
Folkestad, L ;
Granström, G .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2003, 61 (09) :1038-1044
[7]   Long-term sequelae after surgery for orbital floor fractures [J].
Folkestad, L ;
Westin, T .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1999, 120 (06) :914-921
[8]  
Good P., 2000, SPRINGER SERIES STAT
[9]   A COMPARISON OF IMAGING TECHNIQUES WITH SURGICAL EXPERIENCE IN ORBITAL INJURIES - A PROSPECTIVE-STUDY [J].
ILANKOVAN, V ;
HADLEY, D ;
MOOS, K ;
ELATTAR, A .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1991, 19 (08) :348-352
[10]  
JOHNSON CA, 2004, ARVO M