Total Hip Arthroplasty with Robotic Arm Assistance for Precise Cup Positioning: A Case-Control Study

被引:37
作者
Guo, Dong-hui [1 ,2 ]
Li, Xiao-ming [2 ]
Ma, Shi-qiang [2 ]
Zhao, Yun-chao [2 ]
Qi, Chao [2 ]
Xue, Yuan [1 ]
机构
[1] Tianjin Med Univ, Gen Hosp, Dept Orthopaed Surg, Tianjin 300052, Peoples R China
[2] Cangzhou Hosp Integrated Tradit Chinese & Western, Dept Orthopaed Surg, Cangzhou, Peoples R China
关键词
cup positioning; learning curve; robot-assisted surgery; total hip arthroplasty; MALPRACTICE CLAIMS; LEARNING-CURVE; REPLACEMENT; NAVIGATION; PLACEMENT;
D O I
10.1111/os.13334
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective To determine whether more precise cup positioning can be achieved with robot-assisted total hip arthroplasty (THA) as compared to conventional THA. Methods In this study, between July 2019 and May 2021, 93 patients aged 23-75 years with osteonecrosis of the femoral head (ONFH) and adult developmental dysplasia of hip who underwent first hip surgery were included in the study. They were randomly assigned to either the robotic-assisted THA group (n = 45) or the conventional THA group (n = 48). After the operation, all patients were given routine rapid rehabilitation guidance. The duration of operation was recorded to estimate the learning curve through cumulative summation analysis. We compared the demographics, duration of operation, cup positioning, leg length discrepancy, hip offset, and Harris Hip Score between robot-assisted THA and manual THA. Precision in the positioning of the acetabular prosthesis using the MAKO system was also compared between the two groups. Results The mean duration of operation for the robot-assisted THA group was 91.37 +/- 17.34 min (range: 63 to 135 min), which was significantly higher than that for the conventional THA group. When the number of procedures was increased to 13, the duration of operation in the robot-assisted group decreased significantly and gradually became stable. In terms of duration of operation, robot-assisted THA was associated with a learning curve of 13 cases. The mean amount of bleeding in the robot-assisted THA group was not significantly different from that in conventional THA group (328 +/- 210 ml vs 315 +/- 205 ml) (p = 0.741). There was no significant difference in the proportion of prostheses located within Lewinnek's safe zone between robot-assisted THA group and conventional THA group (69.81% vs 64.41%). The leg length discrepancy (LLD) was significantly smaller in the robot-assisted THA group than in the conventional THA group (p < 0.001), but both were within acceptable limits (10 mm). The inclination and anteversion angles of the acetabular prosthesis planned before operations were correlated with the actual measurement (r = 0.857 p < 0.001, r = 0.830, p < 0.001). After surgery, none of the patients experienced hip dislocation, aseptic loosening, or periprosthetic infection during the 3 months of follow-up. Conclusion The proportion of acetabular prostheses in the Lewinnek's safety zone was higher and the extent of LLD was significantly lower in the robot-assisted THA group, as compared to the same metrics in the conventional THA group. The MAKO robot improved the accuracy of implant placement in THA.
引用
收藏
页码:1498 / 1505
页数:8
相关论文
共 31 条
[1]   Stability and leg length equality in total hip arthroplasty [J].
Austin, MS ;
Hozack, WJ ;
Sharkey, PF ;
Rothman, RH .
JOURNAL OF ARTHROPLASTY, 2003, 18 (03) :88-90
[2]   Characterization of 3D Printed Yttria-Stabilized Zirconia Parts for Use in Prostheses [J].
Buj-Corral, Irene ;
Vidal, Daniel ;
Tejo-Otero, Aitor ;
Antonio Padilla, Jose ;
Xuriguera, Elena ;
Fenollosa-Artes, Felip .
NANOMATERIALS, 2021, 11 (11)
[3]   The John Charnley Award Risk Factors for Cup Malpositioning Quality Improvement Through a Joint Registry at a Tertiary Hospital [J].
Callanan, Mark C. ;
Jarrett, Bryan ;
Bragdon, Charles R. ;
Zurakowski, David ;
Rubash, Harry E. ;
Freiberg, Andrew A. ;
Malchau, Henrik .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) :319-329
[4]   TOTAL HIP-REPLACEMENT IN CONGENITAL DISLOCATION AND DYSPLASIA OF THE HIP [J].
CROWE, JF ;
MANI, VJ ;
RANAWAT, CS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1979, 61 (01) :15-23
[5]   Early failure in total hip arthroplasty [J].
Dobzyniak, Matthew ;
Fehring, Thomas K. ;
Odum, Susan .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (447) :76-78
[6]   Minimum 5-Year Outcomes of Robotic-assisted Primary Total Hip Arthroplasty With a Nested Comparison Against Manual Primary Total Hip Arthroplasty: A Propensity Score-Matched Study [J].
Domb, Benjamin G. ;
Chen, Jeffrey W. ;
Lall, Ajay C. ;
Perets, Itay ;
Maldonado, David R. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2020, 28 (20) :847-856
[7]   Leg length discrepancy in computer navigated total hip arthroplasty - how accurate are we? [J].
Ellapparadja, Pregash ;
Mahajan, Vivek ;
Atiya, Sami ;
Sankar, Biju ;
Deep, Kamal .
HIP INTERNATIONAL, 2016, 26 (05) :438-443
[8]   Research Synthesis of Recommended Acetabular Cup Orientations for Total Hip Arthroplasty [J].
Harrison, Claire L. ;
Thomson, Avril I. ;
Cutts, Steven ;
Rowe, Philip J. ;
Riches, Philip E. .
JOURNAL OF ARTHROPLASTY, 2014, 29 (02) :377-382
[9]  
Hsiue Peter P, 2020, Arthroplast Today, V6, P112, DOI 10.1016/j.artd.2019.12.009
[10]  
Illgen Richard L Nd, 2017, Surg Technol Int, V30, P365