A small-body portable graphite calorimeter for dosimetry in low-energy clinical proton beams

被引:47
作者
Palmans, H [1 ]
Thomas, R
Simon, M
Duane, S
Kacperek, A
DuSautoy, A
Verhaegen, F
机构
[1] Natl Phys Lab, Ctr Acoust & Ionising Radiat, Teddington TW11 0LW, Middx, England
[2] Clatterbridge Ctr Oncol, Wirral, Merseyside, England
[3] McGill Univ, Med Phys Unit, Montreal, PQ, Canada
关键词
D O I
10.1088/0031-9155/49/16/019
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Calorimetry has been recommended and performed in proton beams for some time, but never has graphite calorimetry been used as a reference dosimeter in clinical proton beams. Furthermore, only a few calorimetry measurements have been reported in ocular proton beams. In this paper we describe the construction and performance of a small-body portable graphite calorimeter for clinical low-energy proton beams. Perturbation correction factors for the gap effect, volume averaging effect, heat transfer phenomena and impurity effect are calculated and applied in a comparison with ionization chamber dosimetry following IAEA TRS-398. The ratio of absorbed dose to water obtained from the calorimeter measurements and from the ionization measurements varied between 0.983 and 1.019, depending on the beam type and the ionization chamber calibration modality. Standard uncertainties on these values varied between 1.9% and 2.5% including a substantial contribution from the k(Q) values in IAEA TRS-398. The (W-air/e)(p) values inferred from these measurements varied between 33.6 J C-1 and 34.9 J C-1 with similar standard uncertainties. A number of improvements for the small-body portable graphite calorimeter and the experimental set-up are suggested for potential reduction of the uncertainties.
引用
收藏
页码:3737 / 3749
页数:13
相关论文
共 33 条
[1]  
Andreo P, 2000, IAEA TECHNICAL REPOR, V398
[2]  
ANDREO P, 2002, INT S STAND COD PRAC
[3]  
[Anonymous], 1993, 49 ICRU
[4]  
Berger M. J., 1993, NISTIR5113
[5]   THE 62 MEV PROTON-BEAM FOR THE TREATMENT OF OCULAR MELANOMA AT CLATTERBRIDGE [J].
BONNETT, DE ;
KACPEREK, A ;
SHEEN, MA ;
GOODALL, R ;
SAXTON, TE .
BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (790) :907-914
[6]  
COMSOL AB, 2003, FEMLAB REFERENCE MAN
[7]   Proton dosimetry comparison involving ionometry and calorimetry [J].
Delacroix, S ;
Bridier, A ;
Mazal, A ;
Daures, J ;
Ostrowsky, A ;
Nauraye, C ;
Kacperek, A ;
Vynkier, S ;
Brassard, N ;
Habrand, JL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (03) :711-718
[8]  
ICRU, 1998, 59 ICRU
[9]  
ICRU, 2000, icru Report
[10]  
KAYE GWC, 1973, TABLES PHYS CHEM CON