Capillary isoelectric focusing coupled offline to matrix assisted laser desorption/ionization mass spectrometry

被引:12
|
作者
Weiss, Noah G. [1 ]
Zwick, Nicole L. [1 ]
Hayes, Mark A. [1 ]
机构
[1] Arizona State Univ, Dept Chem & Biochem, Tempe, AZ 85287 USA
关键词
Capillary IEF; MALDI-MS; MS; Syringe pump; PROTEIN-ANALYSIS; MS;
D O I
10.1016/j.chroma.2009.11.047
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This work presents several critical details for making cIEF-MALDI-MS a robust technique which will allow for more routine application and aid in automation. This includes emphasis on the hardware necessary for syringe pump mobilization and proper protocol for preventing disruption from gas bubbles. Following these guidelines, excellent elution time reproducibility is demonstrated for six pl markets (RSD < 5%). Additionally, the pl markets are used to calibrate the pH gradient and determine experimental pis of proteins detected offline by mass spectrometry. This was demonstrated using a standard protein mixture of myoglobin and two forms of beta-lactoglobulin. Experimental determination of protein pls and molecular weights were found to be in agreement with literature values. The technical details discussed provide a sound foundation for applying the offline coupling of MALDI-MS with cIEF. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:179 / 182
页数:4
相关论文
共 50 条
  • [1] Peptide mapping using capillary electrophoresis offline coupled to matrix-assisted laser desorption ionization time of flight mass spectrometry
    Bachmann, Stefan
    Bakry, Rania
    Huck, Christian W.
    Polato, Fabio
    Corradini, Danilo
    Bonn, Guenther K.
    ELECTROPHORESIS, 2011, 32 (20) : 2830 - 2839
  • [2] Membrane-assisted capillary isoelectric focusing coupling with matrix-assisted laser desorption/ionization-Fourier transform mass spectrometry for neuropeptide analysis
    Zhang, Zichuan
    Wang, Junhua
    Hui, Limei
    Li, Lingjun
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (31) : 5336 - 5343
  • [3] Compatible buffer for capillary electrophoresis and matrix-assisted laser desorption/ionization mass spectrometry
    Chen, Hong-Xu
    Busnel, Jean-Marc
    Qiao, Liang
    Gasilova, Natalia
    Zhang, Xin-Xiang
    Girault, Hubert H.
    ANALYTICAL METHODS, 2013, 5 (16) : 4258 - 4262
  • [4] Analysis of human blood serum using the off-line coupling of capillary isoelectric focusing to matrix-assisted laser desorption/ionization time of flight mass spectrometry
    Crowley, TA
    Hayes, MA
    PROTEOMICS, 2005, 5 (14) : 3798 - 3804
  • [5] Microfluidic Isoelectric Focusing of Amyloid Beta Peptides Followed by Micropillar-Matrix-Assisted Laser Desorption Ionization-Mass Spectrometry
    Mikkonen, Saara
    Jacksen, Johan
    Roeraade, Johan
    Thormann, Wolfgang
    Emmer, Asa
    ANALYTICAL CHEMISTRY, 2016, 88 (20) : 10044 - 10051
  • [6] Microfluidic Device for Coupling Capillary Electrophoresis and Matrix-Assisted Laser Desorption Ionization-Mass Spectrometry
    Luo, Yiqi
    Xu, Songyun
    Schilling, James W.
    Lau, Kenneth H.
    Whitin, John C.
    Yu, Tom T. S.
    Cohen, Harvey J.
    JALA, 2009, 14 (05): : 252 - 261
  • [7] Sample Preparation for Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry
    Kim, Jeongkwon
    MASS SPECTROMETRY LETTERS, 2015, 6 (02) : 27 - 30
  • [8] Fragmentation matrix assisted laser desorption/ionization mass spectrometry-basics
    Carraher, Charles E., Jr.
    Sabir, Theodore S.
    Carraher, Cara
    JOURNAL OF POLYMER MATERIALS, 2006, 23 (02): : 143 - 151
  • [9] Studies of some characters of matrix influencing desorption ionization processes in matrix-assisted laser desorption ionization mass spectrometry
    Zhao, SK
    Zhong, F
    Chang, JH
    Zhu, ZH
    ANALYTICAL SCIENCES, 1997, 13 : 45 - 48
  • [10] Single Cell Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry Imaging
    Schober, Yvonne
    Guenther, Sabine
    Spengler, Bernhard
    Roempp, Andreas