Development and validation of a high-speed video system for measuring saccadic eye movement

被引:7
作者
Brooks, Jeffrey S. [1 ]
Smith, William J. [1 ]
Webb, Brandon M. [1 ]
Heath, Matthew D. [1 ]
Dickey, James P. [1 ]
机构
[1] Western Univ, Fac Hlth Sci, Sch Kinesiol, London, ON, Canada
关键词
Antisaccades; Prosaccades; Subconcussive impacts; Oculomotor; Brain; Eye tracker; Reaction time;
D O I
10.3758/s13428-019-01197-2
中图分类号
B841 [心理学研究方法];
学科分类号
040201 ;
摘要
Laboratory-based retroreflective and magnetic scleral search-coil technologies are the current standards for collecting saccadometric data, but such equipment is costly and cumbersome. We have validated a novel, portable, high-speed video camera-based system (Exilim EX-FH20, Casio, Tokyo, Japan) for measuring saccade reaction time (RT) and error rate in a well-lit environment. This system would enable measurements of pro- and antisaccades in athletes, which is important because antisaccade metrics provide a valid tool for concussion diagnosis and determining an athlete's safe return to play. A total of 529 trials collected from 15 participants were used to compare saccade RT and error rate measurements of the high-speed camera system to a retroreflective video-based eye tracker (Eye-Trac 6: Applied Sciences Laboratories, Bedford, MA). Bland-Altman analysis revealed that the RT measurements made by the high-speed video system were 11 ms slower than those made by the retroreflective system. Error rate measurements were identical between the two systems. An excellent degree of reliability was found between the system measurements and in the ratings of independent researchers examining the video data. A strong association (r = .97) between the RTs determined via the retroreflective and high-speed camera systems was observed across all trials. Our high-speed camera system is portable and easily set up, does not require extensive equipment calibration, and can be used in a well-lit environment. Accordingly, the camera-based capture of saccadometric data may provide a valuable tool for neurological assessment following a concussive event and for the continued monitoring of recovery.
引用
收藏
页码:2302 / 2309
页数:8
相关论文
共 63 条
[1]  
Allison R.S., Eizenman M., Cheung B.S., Combined head and eye tracking system for dynamic testing of the vestibular system, IEEE Transactions on Biomedical Engineering, 43, pp. 1073-1082, (1996)
[2]  
Andersson R., Nystrom M., Holmqvist K., Sampling frequency and eye-tracking measures: How speed affects durations, latenciesand more, Journal of Eye Movement Research, 3, 3, (2010)
[3]  
Antoniades C., Ettinger U., Gaymard B., Gilchrist I., Kristjansson A., Kennard C., Et al., An internationally standardised antisaccade protocol, Vision Research, 84, pp. 1-5, (2013)
[4]  
Balaban C., Hoffer M.E., Szczupak M., Snapp H., Crawford J., Murphy S., Et al., Oculomotor, vestibular, and reaction time tests in mild traumatic brain injury, PLoS ONE, 11, (2016)
[5]  
Bates D., Machler M., Bolker B., Walker S., Fitting linear mixed-effects models using lme4, Journal of Statistical Software, 67, pp. 1-48, (2015)
[6]  
Bland J.M., Altman D., Statistical methods for assessing agreement between two methods of clinical measurement, The Lancet, 327, pp. 307-310, (1986)
[7]  
Brainard D.H., The Psychophysics Toolbox, Spatial Vision, 10, pp. 433-436, (1997)
[8]  
Bucci M.P., Seassau M., Vertical saccades in children: A developmental study, Experimental Brain Research, 232, pp. 927-934, (2014)
[9]  
Caplan B., Bogner J., Brenner L., Cifu D.X., Wares J.R., Hoke K.W., Et al., Differential eye movements in mild traumatic brain injury versus normal controls, Journal of Head Trauma Rehabilitation, 30, pp. 21-28, (2015)
[10]  
Carpenter R.H.S., Frontal cortex: Choosing where to look, Current Biology, 4, pp. 341-343, (1994)