Thermocapillary actuation by optimized resistor pattern: bubbles and droplets displacing, switching and trapping

被引:62
作者
Selva, Bertrand [1 ]
Miralles, Vincent [2 ]
Cantat, Isabelle [3 ]
Jullien, Marie-Caroline [1 ,2 ]
机构
[1] UEB, CNRS, ENS Cachan Bretagne, SATIE, F-35170 Bruz, France
[2] ESPCI Paris Tech, CNRS, MMN, F-75005 Paris, France
[3] Univ Rennes 1, CNRS, IPR, UMR 6251, F-35000 Rennes, France
关键词
DIELECTROPHORETIC MANIPULATION; MICROFLUIDIC SYSTEMS; PARTICLES; REAGENTS; KINETICS; DEVICES; ARRAYS; FLUID; DROPS; PLUG;
D O I
10.1039/c001900c
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report a novel method for bubble or droplet displacement, capture and switching within a bifurcation channel for applications in digital microfluidics based on the Marangoni effect, i.e. the appearance of thermocapillary tangential interface stresses stemming from local surface tension variations. The specificity of the reported actuation is that heating is provided by an optimized resistor pattern (B. Selva, J. Marchalot and M.-C. Jullien, An optimized resistor pattern for temperature gradient control in microfluidics, J. Micromech. Microeng., 2009, 19, 065002) leading to a constant temperature gradient along a microfluidic cavity. In this context, bubbles or droplets to be actuated entail a surface force originating from the thermal Marangoni effect. This actuator has been characterized (B. Selva, I. Cantat, and M.-C. Jullien, Migration of a bubble towards a higher surface tension under the effect of thermocapillary stress, preprint, 2009) and it was found that the bubble/droplet (called further element) is driven toward a high surface tension region, i.e. toward cold region, and the element velocity increases while decreasing the cavity thickness. Taking advantage of these properties three applications are presented: (1) element displacement, (2) element switching, detailed in a given range of working, in which elements are redirected towards a specific evacuation, (3) a system able to trap, and consequently stop on demand, the elements on an alveolus structure while the continuous phase is still flowing. The strength of this method lies in its simplicity: single layer system, in situ heating leading to a high level of integration, low power consumption (P < 0.4 W), low applied voltage (about 10 V), and finally this system is able to manipulate elements within a flow velocity up to 1 cm s(-1).
引用
收藏
页码:1835 / 1840
页数:6
相关论文
共 32 条
  • [1] Dielectrophoretic manipulation of drops for high-speed microfluidic sorting devices
    Ahn, K
    Kerbage, C
    Hunt, TP
    Westervelt, RM
    Link, DR
    Weitz, DA
    [J]. APPLIED PHYSICS LETTERS, 2006, 88 (02) : 1 - 3
  • [2] Thermocapillary valve for droplet production and sorting
    Baroud, Charles N.
    Delville, Jean-Pierre
    Gallaire, Francois
    Wunenburger, Regis
    [J]. PHYSICAL REVIEW E, 2007, 75 (04):
  • [3] Monodisperse droplet generation and rapid trapping for single molecule detection and reaction kinetics measurement
    Beer, Neil Reginald
    Rose, Klint Aaron
    Kennedy, Ian M.
    [J]. LAB ON A CHIP, 2009, 9 (06) : 841 - 844
  • [4] Simple, robust storage of drops and fluids in a microfluidic device
    Boukellal, Hakim
    Selimovic, Seila
    Jia, Yanwei
    Cristobal, Galder
    Fraden, Seth
    [J]. LAB ON A CHIP, 2009, 9 (02) : 331 - 338
  • [5] Thermocapillary actuation of droplets on chemically patterned surfaces by programmable microheater arrays
    Darhuber, AA
    Valentino, JP
    Troian, SM
    Wagner, S
    [J]. JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2003, 12 (06) : 873 - 879
  • [6] Microfluidic actuation by modulation of surface stresses
    Darhuber, AA
    Valentino, JP
    Davis, JM
    Troian, SM
    Wagner, S
    [J]. APPLIED PHYSICS LETTERS, 2003, 82 (04) : 657 - 659
  • [7] A fast and elitist multiobjective genetic algorithm: NSGA-II
    Deb, K
    Pratap, A
    Agarwal, S
    Meyarivan, T
    [J]. IEEE TRANSACTIONS ON EVOLUTIONARY COMPUTATION, 2002, 6 (02) : 182 - 197
  • [8] Laser microfluidics: fluid actuation by light
    Delville, Jean-Pierre
    de Saint Vincent, Matthieu Robert
    Schroll, Robert D.
    Chraibi, Hamza
    Issenmann, Bruno
    Wunenburger, Regis
    Lasseux, Didier
    Zhang, Wendy W.
    Brasselet, Etienne
    [J]. JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2009, 11 (03):
  • [9] An integrated microfluidic system for reaction, high-sensitivity detection, and sorting of fluorescent cells and particles
    Dittrich, PS
    Schwille, P
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (21) : 5767 - 5774
  • [10] Joule heating and heat transfer in poly(dimethylsiloxane) microfluidic systems
    Erickson, D
    Sinton, D
    Li, DQ