Enantiomeric separation of ivabradine by cyclodextrin-electrokinetic chromatography. Effect of amino acid chiral ionic liquids

被引:36
作者
Casado, Natalia [1 ]
Salgado, Antonio [2 ]
Castro-Puyana, Maria [1 ,3 ]
Angeles Garcia, Maria [1 ,3 ]
Luisa Marina, Maria [1 ,3 ]
机构
[1] Univ Alcala, Dept Quim Analit Quim Fis & Ingn Quim, Ctra Madrid Barcelona Km 33-600, Madrid 28871, Spain
[2] Univ Alcala, CERMN, CAIQ, Ctra Madrid Barcelona Km 33-600, Madrid 28871, Spain
[3] Univ Alcala, Inst Invest Quim Andres M del Rio IQAR, Ctra Madrid Barcelona Km 33-600, Madrid 28871, Spain
关键词
Capillary electrophoresis; Electrokinetic; Chromatography; Ivabradine; Chiral ionic liquids; Enantioseparation; Cyclodextrins; CURRENT INHIBITOR IVABRADINE; HP-BETA-CD; CAPILLARY-ELECTROPHORESIS; INCLUSION COMPLEXES; L-ARGININE; ENANTIOSEPARATION; ADDITIVES; EFFICACY; DRUGS; CE;
D O I
10.1016/j.chroma.2019.460407
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A chiral methodology was developed for the first time to ensure the quality control of ivabradine, a novel anti-ischemic and heart rate lowering drug commercialized as a pure enantiomer. With this aim, electrokinetic chromatography (EKC) was employed and the enantiomeric separation of ivabradine was investigated using different anionic and neutral cyclodextrins (CDs) and amino acid-based chiral ionic liquids (CILs) as sole chiral selectors. Baseline separation was only achieved with sulfated CDs, and the best enantiomeric resolution was obtained with sulfated-gamma-CD. Under the optimized conditions, ivabradine enantiomers were separated in 6 min with a resolution of 2.7. Nuclear magnetic resonance experiments showed a 1:1 stoichiometry for the enantiomer-CD complexes and apparent and averaged equilibrium constants were determined. The combined use of sulfated-gamma-CD and different CILs as dual separation systems was investigated, resulting in a significant increase in the resolution. The use of 5 mM tetrabutylammonium-aspartic acid ([TBA][L-Asp]) in 50 mM formate buffer (pH 2.0) containing 4 mM sulfated-y-CD were considered the best conditions in terms of resolution and migration times for ivabradine enantiomers. Nevertheless, as no inversion of the enantiomer migration order was observed when combining CILs and sulfated-gamma-CD and a good enantiomeric resolution and efficiency were obtained using just sulfated-y-CD as the sole chiral selector, the analytical characteristics of this method were evaluated, showing good recovery (98% and 103% for S- and R-ivabradine, respectively) and precision values (RSD < 5% for instrumental repeatability, < 6% for method repeatability and < 7% for intermediate precision). The limits of detection (LODs) were 0.22 and 0.28 mu g mL(-1) for S- and R-ivabradine, respectively, and the method enabled to detect a 0.1% of the enantiomeric impurity, allowing to accomplish the requirements of the International Conference on Harmonisation (ICH) guidelines. Finally, the method was applied to the analysis of a pharmaceutical formulation of ivabradine. The content of R-ivabradine was below the LOD and the amount of S-ivabradine was in agreement to the labeled content. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 47 条
[1]   Ionic Liquids in HPLC and CE: A Hope for Future [J].
Ali, Imran ;
Suhail, Mohd ;
Sanagi, Mohd Marsin ;
Aboul-Enein, Hassan Y. .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2017, 47 (04) :332-339
[2]   Facile synthesis of ionic liquids possessing chiral carboxylates [J].
Allen, Christine R. ;
Richard, Paulina L. ;
Ward, Antony J. ;
van de Water, Leon G. A. ;
Masters, Anthony F. ;
Maschmeyer, Thomas .
TETRAHEDRON LETTERS, 2006, 47 (41) :7367-7370
[3]   Contemporary theory of enantioseparations in capillary electrophoresis [J].
Chankvetadze, Bezhan .
JOURNAL OF CHROMATOGRAPHY A, 2018, 1567 :2-25
[4]   Combined Use of Ionic Liquid and Hydroxypropyl-β-Cyclodextrin for the Enantioseparation of Ten Drugs by Capillary Electrophoresis [J].
Cui, Yan ;
Ma, Xiaowei ;
Zhao, Min ;
Jiang, Zhen ;
Xu, Shuying ;
Guo, Xingjie .
CHIRALITY, 2013, 25 (07) :409-414
[5]   Heart rate lowering by specific and selective If current inhibition with ivabradine -: A new therapeutic perspective in cardiovascular disease [J].
DiFrancesco, D ;
Camm, JA .
DRUGS, 2004, 64 (16) :1757-1765
[6]  
European Medicines Agency (EMA), 2019, IVABRADINE AUTHORIZA
[7]  
European Pharmacopoeia, 2004, THE EUROPEAN PHARMAC, P3843
[8]   The Role of L-arginine in Inclusion Complexes of Omeprazole with Cyclodextrins [J].
Figueiras, Ana ;
Sarraguca, Jorge M. G. ;
Pais, Alberto A. C. C. ;
Carvalho, Rui A. ;
Veiga, J. Francisco .
AAPS PHARMSCITECH, 2010, 11 (01) :233-240
[9]   Ivabradine for patients with stable coronary artery disease and left-ventricular systolic dysfunction (BEAUTIFUL): a randomised, double-blind, placebo-controlled trial [J].
Fox, Kim ;
Ford, Ian ;
Steg, P. Gabriel ;
Tendera, Michal ;
Ferrari, Roberto .
LANCET, 2008, 372 (9641) :807-816
[10]   Evaluation of chiral ionic liquids as additives to cyclodextrins for enantiomeric separations by capillary electrophoresis [J].
Francois, Yannis ;
Varenne, Anne ;
Juillerat, Emilie ;
Villemin, Didier ;
Gareil, Pierre .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1155 (02) :134-141