Validity and reliability of bioelectrical impedance analysis to estimate body fat percentage against air displacement plethysmography and dual-energy X-ray absorptiometry

被引:63
|
作者
von Hurst, Pamela R. [1 ]
Walsh, Daniel C. I. [2 ]
Conlon, Cathryn A. [1 ]
Ingram, Michelle [1 ]
Kruger, Rozanne [1 ]
Stonehouse, Welma [1 ,3 ]
机构
[1] Massey Univ, Coll Hlth, Human Nutr & Dietet, Auckland 0745, New Zealand
[2] Massey Univ, Inst Nat & Math Sci, Auckland 0745, New Zealand
[3] CSIRO Anim Food & Hlth Sci, Adelaide, SA, Australia
关键词
bioelectrical impedance; BodPod; body composition; body fat percentage; DXA; obesity; VALIDATION; CHILDREN; DEXA; MEN;
D O I
10.1111/1747-0080.12172
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Air displacement plethysmography (ADP) and dual-energy X-ray absorptiometry (DXA) are well-regarded methods for predicting body fat percentage (BF%). Bioelectrical impedance analysis (BIA) also predicts BF% and has distinct advantages in research settings. Aim: To assess the validity of BIA against ADP and DXA to measure BF%, and to test the reliability of each method. Methods: Adults (n = 166) with a wide range of body mass index (19-38 kg/m(2)) were tested twice during a 5-day period. ADP was conducted in a BodPod (Life Measurement Inc, Concord, CA, USA); DXA measurements on a QDR Discovery A (Hologic) and BIA measurements used the InBody 230 (Biospace Ltd., Seoul, Korea). Agreement between measurements was analysed using t-tests, effect size, linear regression models and method of triads (estimating true value). Results: BIA showed excellent relative agreement to the estimated true value (rho = 0.97 (0.96, 0.98)) and to ADP (R-2 = 0.88) and DXA (R-2 = 0.92), but wide limits of agreement (-4.25 to 8.37%). BIA underestimated BF% by 2%, across all values. DXA showed excellent relative agreement to the estimated true value (rho = 0.97 (0.96, 0.98)) and with ADP (R-2 = 0.92), good absolute agreement but wide limits of agreement (-6.13 to 6.91%) and under- and overestimation at high and low BF% levels, respectively. All methods showed excellent reliability with repeat measurements differing by less than 0.2% with very small 95% CIs. Conclusions: BIA may be a valid method in research and population samples. All three methods showed excellent reliability.
引用
收藏
页码:197 / 204
页数:8
相关论文
共 50 条
  • [21] Body Composition with Dual-Energy X-Ray Absorptiometry and Bioelectrical Impedance Analysis in Breast Cancer Survivors
    Lee, Kyuwan
    Sami, Nathalie
    Sweeney, Frank C.
    Dieli-Conwright, Christina M.
    NUTRITION IN CLINICAL PRACTICE, 2019, 34 (03) : 421 - 427
  • [22] Percentage of Body Fat Assessment Using Bioelectrical Impedance Analysis and Dual-Energy X-ray Absorptiometry in a Weight Loss Program for Obese or Overweight Chinese Adults
    Li, Yi-Chun
    Li, Chia-Ing
    Lin, Wen-Yuan
    Liu, Chiu-Shong
    Hsu, Hua-Shui
    Lee, Cheng-Chun
    Chen, Fei-Na
    Li, Tsai-Chung
    Lin, Cheng-Chieh
    PLOS ONE, 2013, 8 (04):
  • [23] Comparison of two bioelectrical impedance devices and dual-energy X-ray absorptiometry to evaluate body composition in heart failure
    Alves, F. D.
    Souza, G. C.
    Biolo, A.
    Clausell, N.
    JOURNAL OF HUMAN NUTRITION AND DIETETICS, 2014, 27 (06) : 632 - 638
  • [24] Validation of rapid 4-component body composition assessment with the use of dual-energy X-ray absorptiometry and bioelectrical impedance analysis
    Ng, Bennett K.
    Liu, Yong L.
    Wang, Wei
    Kelly, Thomas L.
    Wilson, Kevin E.
    Schoeller, Dale A.
    Heymsfield, Steven B.
    Shepherd, John A.
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2018, 108 (04) : 708 - 715
  • [25] Bioelectrical impedance analysis to estimate body composition, and change in adiposity, in overweight and obese adolescents: comparison with dual-energy x-ray absorptiometry
    Wan, Ching S.
    Ward, Leigh C.
    Halim, Jocelyn
    Gow, Megan L.
    Ho, Mandy
    Briody, Julie N.
    Leung, Kelvin
    Cowell, Chris T.
    Garnett, Sarah P.
    BMC PEDIATRICS, 2014, 14
  • [26] Pediatric body composition analysis with dual-energy X-ray absorptiometry
    Maura Helba
    Larry A. Binkovitz
    Pediatric Radiology, 2009, 39 : 647 - 656
  • [27] Pediatric body composition analysis with dual-energy X-ray absorptiometry
    Helba, Maura
    Binkovitz, Larry A.
    PEDIATRIC RADIOLOGY, 2009, 39 (07) : 647 - 656
  • [28] Comparison of Bioelectrical Impedance Analysis and Dual-Energy X-Ray Absorptiometry for Estimating Bone Mineral Content
    Stone, Tori M.
    Wingo, Jonathan E.
    Nickerson, Brett S.
    Esco, Michael R.
    INTERNATIONAL JOURNAL OF SPORT NUTRITION AND EXERCISE METABOLISM, 2018, 28 (05) : 542 - 546
  • [29] A comparison of body composition estimates using dual-energy X-ray absorptiometry and air-displacement plethysmography in South African neonates
    Wrottesley, S. V.
    Pisa, P. T.
    Micklesfield, L. K.
    Pettifor, J. M.
    Norris, S. A.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2016, 70 (11) : 1254 - 1258
  • [30] Relationships among dual-energy X-ray absorptiometry, bioelectrical impedance and ultrasound measurements of body composition of swine
    Mitchell, Alva D.
    Scholz, Armin M.
    ARCHIV FUR TIERZUCHT-ARCHIVES OF ANIMAL BREEDING, 2009, 52 (01): : 28 - 39