Calibration transfer of near infrared spectrometers for the assessment of plasma ethanol precipitation process

被引:10
作者
Sun, Zhongyu [1 ,2 ]
Wang, Jiayue [1 ,2 ]
Nie, Lei [3 ]
Li, Lian [4 ]
Cao, Dawei [5 ]
Fan, Jiajin [5 ]
Wang, Haiyan [1 ,2 ]
Liu, Ruichen [1 ,2 ]
Zhang, Yinran [6 ]
Zang, Hengchang [1 ,2 ]
机构
[1] Shandong Univ, Sch Pharmaceut Sci, Wenhuaxi Rd 44, Jinan 250012, Shandong, Peoples R China
[2] Shandong Univ, Natl Glycoengn Res Ctr, Wenhuaxi Rd 44, Jinan 250012, Shandong, Peoples R China
[3] Shandong Univ, Sch Pharmaceut Sci & Pharmaceut Anal, Wenhuaxi Rd 44, Jinan 250012, Shandong, Peoples R China
[4] Shandong Univ, Sch Basic Med Sci, Wenhuaxi Rd 44, Jinan 250012, Shandong, Peoples R China
[5] Shandong Taibang Biol Prod Ltd Co, East Hushan Rd 14, Tai An 271000, Shandong, Peoples R China
[6] Ohio State Univ, Dept Chem & Biochem, Newman & Wolfram Lab, 100 West 18th Ave, Columbus, OH 43210 USA
基金
美国国家科学基金会;
关键词
Calibration transfer; Plasma ethanol precipitation; Near infrared spectroscopy (NIRS); Piecewise reverse standardization (PRS); Rank sample set partitioning based on joint x-y distance (Rank-SPXY); Process analytical technology (PAT); MULTIVARIATE CALIBRATION; CORRELATION-COEFFICIENT; ALCOHOL PRECIPITATION; FOURIER-TRANSFORM; NIR SPECTRA; MICRO-NIR; STANDARDIZATION; QUALITY; SPECTROSCOPY; INSTRUMENTS;
D O I
10.1016/j.chemolab.2018.08.012
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Plasma ethanol precipitation process is an important step in the biopharmacy production process, and near infrared spectroscopy (NIBS) is an effective process analytical technology (PAT) tool in detecting the key quality attribute: the total protein (TP) content. But establishing a robust model is pretty complex. The aim of this study was to explore the calibration transfer strategy between master and slave spectrometers with the biopharmacy. Firstly, 8 batches of ethanol precipitation process were experimented. The changing spectra were collected by two spectrometers, reference values were measured by biuret method. Then, calibration transfer based on the PRS algorithm was carried out. Finally, before establishment of the optimal TP content partial least squares regression (PLSR) model of calibration transfer, rank sample set partitioning based on joint x-y distance (Rank-SPXY) and spectral pretreatment methods were selected after comparison. The determination coefficients of prediction (R-p(2)) and root mean squares error of prediction (RMSEP) were 0.934 and 0.8395 g/L, respectively. The results showed that Rank-SPXY-PRS was an effective calibration transfer strategy with different NIBS spectrometers. To some extent, the predictive capability of PLSR model was improved after calibration transfer, and it could provide reference for the further research in biopharmacy production process.
引用
收藏
页码:64 / 71
页数:8
相关论文
共 59 条
  • [31] An Optimal Selection Method of Samples of Calibration Set and Validation Set for Spectral Multivariate Analysis
    Liu Wei
    Zhao Zhong
    Yuan Hong-fu
    Song Chun-feng
    Li Xiao-yu
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (04) : 947 - 951
  • [32] Near-Infrared Spectroscopy as an Analytical Process Technology for the On-Line Quantification of Water Precipitation Processes during Danhong Injection
    Liu, Xuesong
    Wu, Chunyan
    Geng, Shu
    Jin, Ye
    Luan, Lianjun
    Chen, Yong
    Wu, Yongjiang
    [J]. INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 2015
  • [33] Liu Y., 2016, ACTA PEDOL SIN, V2
  • [34] Comparing the analytical performances of Micro-NIR and Ft-NIR spectrometers in the evaluation of acerola fruit quality, using PLS and SVM regression algorithms
    Malegori, Cristina
    Nascimento Marques, Emanuel Jose
    de Freitas, Sergio Tonetto
    Pimentel, Maria Fernanda
    Pasquini, Celio
    Casiraghi, Ernestina
    [J]. TALANTA, 2017, 165 : 112 - 116
  • [35] The interprocess NIR sampling as an alternative approach to multivariate statistical process control for identifying sources of product-quality variability
    Markovic, Snezana
    Kerc, Janez
    Horvat, Matej
    [J]. DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2017, 43 (03) : 379 - 389
  • [36] Coupling process for plasma protein fractionation using ethanol precipitation and ion exchange chromatography
    Moure, F
    Rendueles, M
    Díaz, M
    [J]. MEAT SCIENCE, 2003, 64 (04) : 391 - 398
  • [37] A Pearson's correlation coefficient based decision tree and its parallel implementation
    Mu, Yashuang
    Liu, Xiaodong
    Wang, Lidong
    [J]. INFORMATION SCIENCES, 2018, 435 : 40 - 58
  • [38] Ozaki Y., 2005, S CHEM INF COMP SCI
  • [39] A comparative study of calibration transfer methods for determination of gasoline quality parameters in three different near infrared spectrometers
    Pereira, Claudete Fernandes
    Pimentel, Maria Fernanda
    Harrop Galvao, Roberto Kawakami
    Honorato, Fernanda Araujo
    Stragevitch, Luiz
    Martins, Marcelo Nascimento
    [J]. ANALYTICA CHIMICA ACTA, 2008, 611 (01) : 41 - 47
  • [40] Calibration transfer from powder mixtures to intact tablets: A new use in pharmaceutical analysis for a known tool
    Pereira, Leandro S. A.
    Carneiro, Maira F.
    Botelho, Bruno G.
    Sena, Marcelo M.
    [J]. TALANTA, 2016, 147 : 351 - 357