A robust adaptive denoising framework for real-time artifact removal in scalp EEG measurements

被引:100
作者
Kilicarslan, Atilla [1 ,3 ]
Grossman, Robert G. [1 ,2 ]
Contreras-Vidal, Jose Luis [1 ,3 ]
机构
[1] Univ Houston, Lab Noninvas Brain Machine Interface Syst, Dept Elect & Comp Engn, Houston, TX USA
[2] Houston Methodist Hosp, Dept Neurosurg, Houston, TX USA
[3] Houston Methodist Hosp, Houston Methodist Res Inst, Houston, TX USA
关键词
brain machine interfaces; EEG; real-time artifact removal; brain computer interfaces; denoising; EOG; INDEPENDENT COMPONENT ANALYSIS; ELECTRODE IMPEDANCE; AUTOMATIC REMOVAL; OCULAR ARTIFACT;
D O I
10.1088/1741-2560/13/2/026013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Non-invasive measurement of human neural activity based on the scalp electroencephalogram (EEG) allows for the development of biomedical devices that interface with the nervous system for scientific, diagnostic, therapeutic, or restorative purposes. However, EEG recordings are often considered as prone to physiological and non physiological artifacts of different types and frequency characteristics. Among them, ocular artifacts and signal drifts represent major sources of EEG contamination, particularly in real-time closed -loop brain machine interface (BMI) applications, which require effective handling of these artifacts across sessions and in natural settings. Approach. We extend the usage of a robust adaptive noise cancelling (ANC) scheme (H-infinity filtering) for removal of eye blinks, eye motions, amplitude drifts and recording biases simultaneously. We also characterize the volume conduction, by estimating the signal propagation levels across all EEG scalp recording areas due to ocular artifact generators. We find that the amplitude and spatial distribution of ocular artifacts vary greatly depending on the electrode location. Therefore, fixed filtering parameters for all recording areas would naturally hinder the true overall performance of an ANC scheme for artifact removal. We treat each electrode as a separate sub-system to be filtered, and without the loss of generality, they are assumed to be uncorrelated and uncoupled. Main results. Our results show over 95-99.9% correlation between the raw and processed signals at non -ocular artifact regions, and depending on the contamination profile, 40-70% correlation when ocular artifacts are dominant. We also compare our results with the offline independent component analysis and artifact subspace reconstruction methods, and show that some local quantities are handled better by our sample -adaptive real-time framework. Decoding performance is also compared with multi -day experimental data from 2 subjects, totaling 19 sessions, with and without H filtering of the raw data. Significance. The proposed method allows real-time adaptive artifact removal for EEG-based closed-loop BMI applications and mobile EEG studies in general, thereby increasing the range of tasks that can be studied in action and context while reducing the need for discarding data due to artifacts. Significant increase in decoding performances also justify the effectiveness of the method to be used in real-time closed -loop BMI applications.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] A Real-Time Edge-Preserving Denoising Filter
    Reich, Simon
    Worgotter, Florentin
    Dellen, Babette
    VISAPP: PROCEEDINGS OF THE 13TH INTERNATIONAL JOINT CONFERENCE ON COMPUTER VISION, IMAGING AND COMPUTER GRAPHICS THEORY AND APPLICATIONS - VOL 4: VISAPP, 2018, : 85 - 94
  • [42] A fast and scalable framework for automated artifact recognition from EEG signals represented in scalp topographies of Independent Components
    Placidi, Giuseppe
    Cinque, Luigi
    Polsinelli, Matteo
    COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 132
  • [43] REAL-TIME DENOISING OF TOF MEASUREMENTS BY SPATIO-TEMPORAL NON-LOCAL MEAN FILTERING
    Georgiev, Mihail
    Gotchev, Atanas
    Hannuksela, Miska
    ELECTRONIC PROCEEDINGS OF THE 2013 IEEE INTERNATIONAL CONFERENCE ON MULTIMEDIA AND EXPO WORKSHOPS (ICMEW), 2013,
  • [44] Ocular and cardiac artifact rejection for real-time analysis in MEG
    Breuer, Lukas
    Dammers, Juergen
    Roberts, Timothy P. L.
    Shah, N. Jon
    JOURNAL OF NEUROSCIENCE METHODS, 2014, 233 : 105 - 114
  • [45] Real Time Adaptive Denoising of Musical Signals in Wavelet Domain
    Verma, Neema
    Verma, A. K.
    3RD NIRMA UNIVERSITY INTERNATIONAL CONFERENCE ON ENGINEERING (NUICONE 2012), 2012,
  • [46] Automated Real-Time Epileptic Seizure Detection in Scalp EEG Recordings Using an Algorithm Based on Wavelet Packet Transform
    Zandi, Ali Shahidi
    Javidan, Manouchehr
    Dumont, Guy A.
    Tafreshi, Reza
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (07) : 1639 - 1651
  • [47] EEG Artifact Signals Tracking and Filtering in Real Time for Command Control Application
    Moghavvemi, M.
    Attaran, A.
    Esfahani, M. H. Moshrefpour
    5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011), 2011, 35 : 503 - +
  • [48] IC-U-Net: A U-Net-based Denoising Autoencoder Using Mixtures of Independent Components for Automatic EEG Artifact Removal
    Chuang, Chun-Hsiang
    Chang, Kong-Yi
    Huang, Chih-Sheng
    Jung, Tzyy-Ping
    NEUROIMAGE, 2022, 263
  • [49] Ensemble framework based real-time respiratory motion prediction for adaptive radiotherapy applications
    Tatinati, Sivanagaraja
    Nazarpour, Kianoush
    Ang, Wei Tech
    Veluvolu, Kalyana C.
    MEDICAL ENGINEERING & PHYSICS, 2016, 38 (08) : 749 - 757
  • [50] Adaptive Principal Component Analysis Based Recursive Least Squares for Artifact Removal of EEG Signals
    Turnip, Arjon
    Siahaan, Mery
    ADVANCED SCIENCE LETTERS, 2014, 20 (10-12) : 2034 - 2037