A robust adaptive denoising framework for real-time artifact removal in scalp EEG measurements

被引:100
作者
Kilicarslan, Atilla [1 ,3 ]
Grossman, Robert G. [1 ,2 ]
Contreras-Vidal, Jose Luis [1 ,3 ]
机构
[1] Univ Houston, Lab Noninvas Brain Machine Interface Syst, Dept Elect & Comp Engn, Houston, TX USA
[2] Houston Methodist Hosp, Dept Neurosurg, Houston, TX USA
[3] Houston Methodist Hosp, Houston Methodist Res Inst, Houston, TX USA
关键词
brain machine interfaces; EEG; real-time artifact removal; brain computer interfaces; denoising; EOG; INDEPENDENT COMPONENT ANALYSIS; ELECTRODE IMPEDANCE; AUTOMATIC REMOVAL; OCULAR ARTIFACT;
D O I
10.1088/1741-2560/13/2/026013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Non-invasive measurement of human neural activity based on the scalp electroencephalogram (EEG) allows for the development of biomedical devices that interface with the nervous system for scientific, diagnostic, therapeutic, or restorative purposes. However, EEG recordings are often considered as prone to physiological and non physiological artifacts of different types and frequency characteristics. Among them, ocular artifacts and signal drifts represent major sources of EEG contamination, particularly in real-time closed -loop brain machine interface (BMI) applications, which require effective handling of these artifacts across sessions and in natural settings. Approach. We extend the usage of a robust adaptive noise cancelling (ANC) scheme (H-infinity filtering) for removal of eye blinks, eye motions, amplitude drifts and recording biases simultaneously. We also characterize the volume conduction, by estimating the signal propagation levels across all EEG scalp recording areas due to ocular artifact generators. We find that the amplitude and spatial distribution of ocular artifacts vary greatly depending on the electrode location. Therefore, fixed filtering parameters for all recording areas would naturally hinder the true overall performance of an ANC scheme for artifact removal. We treat each electrode as a separate sub-system to be filtered, and without the loss of generality, they are assumed to be uncorrelated and uncoupled. Main results. Our results show over 95-99.9% correlation between the raw and processed signals at non -ocular artifact regions, and depending on the contamination profile, 40-70% correlation when ocular artifacts are dominant. We also compare our results with the offline independent component analysis and artifact subspace reconstruction methods, and show that some local quantities are handled better by our sample -adaptive real-time framework. Decoding performance is also compared with multi -day experimental data from 2 subjects, totaling 19 sessions, with and without H filtering of the raw data. Significance. The proposed method allows real-time adaptive artifact removal for EEG-based closed-loop BMI applications and mobile EEG studies in general, thereby increasing the range of tasks that can be studied in action and context while reducing the need for discarding data due to artifacts. Significant increase in decoding performances also justify the effectiveness of the method to be used in real-time closed -loop BMI applications.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] A method for real-time artifact filtering during simultaneous EEG/fMRI acquisition:: preliminary results
    Gualniera, G
    Garreffa, G
    Morasso, P
    Carnì, M
    Granozio, G
    Repetti, A
    De Carli, D
    Ricci, GB
    Pantano, P
    Bozzao, L
    Nucclarelli, V
    Roma, V
    Maraviglia, B
    COMPUTATIONAL NEUROSCIENCE: TRENDS IN RESEARCH 2004, 2004, : 1171 - 1179
  • [22] Design of optimized adaptive filter for artifact removal from EEG signal
    Behera, Sandhyalati
    Mohanty, Mihir Narayan
    Mohapatra, Saumendra Kumar
    JOURNAL OF STATISTICS AND MANAGEMENT SYSTEMS, 2023, 26 (01) : 201 - 212
  • [23] Adaptive Filtering based Artifact Removal from Electroencephalogram (EEG) Signals
    Kher, Rahul
    Gandhi, Riddhish
    2016 INTERNATIONAL CONFERENCE ON COMMUNICATION AND SIGNAL PROCESSING (ICCSP), VOL. 1, 2016, : 561 - 564
  • [24] ECG Artifact Removal of EEG signal using Adaptive Neural Network
    Routray, Lipsa
    Biswal, Pradyut
    Pattanaik, Satya Ranjan
    2018 IEEE 13TH INTERNATIONAL CONFERENCE ON INDUSTRIAL AND INFORMATION SYSTEMS (IEEE ICIIS), 2018, : 116 - 119
  • [25] Robust ECG Artifact Removal From EEG Using Continuous Wavelet Transformation and Linear Regression
    Dora, Chinmayee
    Biswal, Pradyut Kumar
    2016 INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND COMMUNICATIONS (SPCOM), 2016,
  • [26] Online EEG artifact removal for BCI applications by adaptive spatial filtering
    Guarnieri, Roberto
    Marino, Marco
    Barban, Federico
    Ganzetti, Marco
    Mantini, Dante
    JOURNAL OF NEURAL ENGINEERING, 2018, 15 (05)
  • [27] Cardiac Artifact Noise Removal From Sleep EEG Signals Using Hybrid Denoising Model
    Ranjan, Rakesh
    Sahana, Bikash Chandra
    Bhandari, Ashish Kumar
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [28] An Efficient and Robust Muscle Artifact Removal Method for Few-Channel EEG
    Liu, Yan
    Zhou, Yuanfeng
    Lang, Xun
    Liu, Yipeng
    Zheng, Qian
    Zhang, Yanjiong
    Jiang, Xu
    Zhang, Li
    Tang, Jihong
    Dai, Yakang
    IEEE ACCESS, 2019, 7 : 176036 - 176050
  • [29] Real-time ocular artifacts removal of EEG data using a hybrid ICA-ANC approach
    Jafarifarmand, Aysa
    Badamchizadeh, Mohammad-Ali
    Khanmohammadi, Sohrab
    Nazari, Mohammad Ali
    Tazehkand, Behzad Mozaffari
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2017, 31 : 199 - 210
  • [30] Real-Time Subspace Denoising of Polysomnographic Data
    Metsis, Vangelis
    Schizas, Ioannis D.
    Marshall, Gregg
    8TH ACM INTERNATIONAL CONFERENCE ON PERVASIVE TECHNOLOGIES RELATED TO ASSISTIVE ENVIRONMENTS (PETRA 2015), 2015,