A robust adaptive denoising framework for real-time artifact removal in scalp EEG measurements

被引:100
作者
Kilicarslan, Atilla [1 ,3 ]
Grossman, Robert G. [1 ,2 ]
Contreras-Vidal, Jose Luis [1 ,3 ]
机构
[1] Univ Houston, Lab Noninvas Brain Machine Interface Syst, Dept Elect & Comp Engn, Houston, TX USA
[2] Houston Methodist Hosp, Dept Neurosurg, Houston, TX USA
[3] Houston Methodist Hosp, Houston Methodist Res Inst, Houston, TX USA
关键词
brain machine interfaces; EEG; real-time artifact removal; brain computer interfaces; denoising; EOG; INDEPENDENT COMPONENT ANALYSIS; ELECTRODE IMPEDANCE; AUTOMATIC REMOVAL; OCULAR ARTIFACT;
D O I
10.1088/1741-2560/13/2/026013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Non-invasive measurement of human neural activity based on the scalp electroencephalogram (EEG) allows for the development of biomedical devices that interface with the nervous system for scientific, diagnostic, therapeutic, or restorative purposes. However, EEG recordings are often considered as prone to physiological and non physiological artifacts of different types and frequency characteristics. Among them, ocular artifacts and signal drifts represent major sources of EEG contamination, particularly in real-time closed -loop brain machine interface (BMI) applications, which require effective handling of these artifacts across sessions and in natural settings. Approach. We extend the usage of a robust adaptive noise cancelling (ANC) scheme (H-infinity filtering) for removal of eye blinks, eye motions, amplitude drifts and recording biases simultaneously. We also characterize the volume conduction, by estimating the signal propagation levels across all EEG scalp recording areas due to ocular artifact generators. We find that the amplitude and spatial distribution of ocular artifacts vary greatly depending on the electrode location. Therefore, fixed filtering parameters for all recording areas would naturally hinder the true overall performance of an ANC scheme for artifact removal. We treat each electrode as a separate sub-system to be filtered, and without the loss of generality, they are assumed to be uncorrelated and uncoupled. Main results. Our results show over 95-99.9% correlation between the raw and processed signals at non -ocular artifact regions, and depending on the contamination profile, 40-70% correlation when ocular artifacts are dominant. We also compare our results with the offline independent component analysis and artifact subspace reconstruction methods, and show that some local quantities are handled better by our sample -adaptive real-time framework. Decoding performance is also compared with multi -day experimental data from 2 subjects, totaling 19 sessions, with and without H filtering of the raw data. Significance. The proposed method allows real-time adaptive artifact removal for EEG-based closed-loop BMI applications and mobile EEG studies in general, thereby increasing the range of tasks that can be studied in action and context while reducing the need for discarding data due to artifacts. Significant increase in decoding performances also justify the effectiveness of the method to be used in real-time closed -loop BMI applications.
引用
收藏
页数:16
相关论文
共 50 条
  • [11] EEG artifact removal and noise suppression by Discrete Orthonormal S-Transform denoising
    Upadhyay, R.
    Padhy, P. K.
    Kankar, P. K.
    COMPUTERS & ELECTRICAL ENGINEERING, 2016, 53 : 125 - 142
  • [12] EEG Artifact Removal System for Depression Using a Hybrid Denoising Approach
    Kaur, Chamandeep
    Singh, Preeti
    Sahni, Sukhtej
    BASIC AND CLINICAL NEUROSCIENCE, 2021, 12 (04) : 465 - 476
  • [13] Automatic ECG artifact removal in the real-time SEMG recording system
    Hu, Yong
    Kwok, Jerry
    Tse, Jessica
    2013 IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND VIRTUAL ENVIRONMENTS FOR MEASUREMENT SYSTEMS AND APPLICATIONS (CIVEMSA), 2013, : 72 - 77
  • [14] Artifact removal of EEG data using wavelet total variation denoising and independent component analysis
    Veeramalla, Santhosh Kumar
    Tatiparthi, Vasu Deva Reddy
    Babu, E. Bharat
    Sahoo, Ratikanta
    Rao, T. V. K. Hanumantha
    ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2025, 122 (02)
  • [15] A system for automatic artifact removal in ictal scalp EEG based on independent component analysis and Bayesian classification
    LeVan, P
    Urrestarazu, E
    Gotman, J
    CLINICAL NEUROPHYSIOLOGY, 2006, 117 (04) : 912 - 927
  • [16] Real-time fetal heart monitoring in biomagnetic measurements using adaptive real-time ICA
    Waldert, Stephan
    Bensch, Michael
    Bogdan, Martin
    Rosenstiel, Wolfgang
    Schoelkopf, Bernhard
    Lowery, Curtis L.
    Eswaran, Hari
    Preissl, Hubert
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (10) : 1867 - 1874
  • [17] Ballistocardiogram artifact removal from EEG signals using adaptive filtering of EOG signals
    In, Myung H.
    Lee, Soo Y.
    Park, Tae S.
    Kim, Tae-S
    Cho, Min H.
    Ahn, Young B.
    PHYSIOLOGICAL MEASUREMENT, 2006, 27 (11) : 1227 - 1240
  • [18] An unsupervised eye blink artifact detection method for real-time electroencephalogram processing
    Chang, Won-Du
    Lim, Jeong-Hwan
    Im, Chang-Hwan
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (03) : 401 - 417
  • [19] Kurtosis-based blind source extraction of complex non-circular signals with application in EEG artifact removal in real-time
    Javidi, Soroush
    Mandic, Danilo P.
    Took, Clive Cheong
    Cichocki, Andrzej
    FRONTIERS IN NEUROSCIENCE, 2011, 5
  • [20] A method for real-time artifact filtering during simultaneous EEG/fMRI acquisition:: preliminary results
    Gualniera, G
    Garreffa, G
    Morasso, P
    Carnì, M
    Granozio, G
    Repetti, A
    De Carli, D
    Ricci, GB
    Pantano, P
    Bozzao, L
    Nucciarelli, V
    Roma, V
    Maraviglia, B
    NEUROCOMPUTING, 2004, 58 : 1171 - 1179