High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner

被引:524
作者
Qi, JY
Leahy, RM
Cherry, SR
Chatziioannou, A
Farquhar, TH
机构
[1] Univ So Calif, Inst Signal & Image Proc, Los Angeles, CA 90089 USA
[2] Univ Calif Los Angeles, Sch Med, Crump Inst Biol Imaging, Div Imaging Sci, Los Angeles, CA 90024 USA
关键词
D O I
10.1088/0031-9155/43/4/027
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A Bayesian method is described for reconstruction of high-resolution 3D images from the microPET small-animal scanner. Resolution recovery is achieved by explicitly modelling the depth dependent geometric sensitivity for each voxel in combination with an accurate detector response model that includes factors due to photon pair non-collinearity and inter-crystal scatter and penetration. To reduce storage and computational costs we use a factored matrix in which the detector response is modelled using a sinogram blurring kernel. Maximum a posteriori (MAP) images are reconstructed using this model in combination with a Poisson likelihood function and a Gibbs prior on the image. Reconstructions obtained from point source data using the accurate system model demonstrate a potential for near-isotropic FWHM resolution of approximately 1.2 mm at the center of the held of view compared with approximately 2 mm when using an analytic 3D reprojection (3DRP) method with a ramp filter. These results also show the ability of the accurate system model to compensate for resolution loss due to crystal penetration producing nearly constant radial FWHM resolution of 1 mm out to a 4 mm radius. Studies with a point source in a uniform cylinder indicate that as the resolution of the image is reduced to control noise propagation the resolution obtained using the accurate system model is superior to that obtained using 3DRP at matched background noise levels. Additional studies using pie phantoms with hot and cold cylinders of diameter 1-2.5 mm and (18)FDG animal studies appear to confirm this observation.
引用
收藏
页码:1001 / 1013
页数:13
相关论文
共 21 条
  • [1] A unified approach to statistical tomography using coordinate descent optimization
    Bouman, CA
    Sauer, K
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 1996, 5 (03) : 480 - 492
  • [2] A row-action alternative to the EM algorithm for maximizing likelihoods in emission tomography
    Browne, J
    DePierro, AR
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (05) : 687 - 699
  • [3] CHEN C, 1991, IEEE T MED IMAGING, V110, P513
  • [4] MicroPET: A high resolution PET scanner for imaging small animals
    Cherry, SR
    Shao, Y
    Silverman, RW
    Meadors, K
    Siegel, S
    Chatziioannou, A
    Young, JW
    Jones, WF
    Moyers, JC
    Newport, D
    Boutefnouchet, A
    Farquhar, TH
    Andreaco, M
    Paulus, MJ
    Binkley, DM
    Nutt, R
    Phelps, ME
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 1161 - 1166
  • [5] FULLY 3-DIMENSIONAL POSITRON EMISSION TOMOGRAPHY
    COLSHER, JG
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (01) : 103 - 115
  • [6] Exact and approximate rebinning algorithms for 3-D PET data
    Defrise, M
    Kinahan, PE
    Townsend, DW
    Michel, C
    Sibomana, M
    Newport, DF
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) : 145 - 158
  • [7] PENALIZED WEIGHTED LEAST-SQUARES IMAGE-RECONSTRUCTION FOR POSITRON EMISSION TOMOGRAPHY
    FESSLER, JA
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (02) : 290 - 300
  • [8] ACCELERATED IMAGE-RECONSTRUCTION USING ORDERED SUBSETS OF PROJECTION DATA
    HUDSON, HM
    LARKIN, RS
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) : 601 - 609
  • [9] COMPENSATION FOR CRYSTAL PENETRATION IN HIGH-RESOLUTION POSITRON TOMOGRAPHY
    HUESMAN, RH
    SALMERON, EM
    BAKER, JR
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 1100 - 1107
  • [10] Evaluation of 3D reconstruction algorithms for a small animal PET camera
    Johnson, CA
    Seidel, J
    Carson, RE
    Gandler, WR
    Sofer, A
    Green, MV
    DaubeWitherspoon, ME