Electromagnetic Design and Performance of a Conical Microwave Blackbody Target for Radiometer Calibration

被引:11
|
作者
Houtz, Derek A. [1 ,2 ]
Emery, William [2 ]
Gu, Dazhen [1 ]
Jacob, Karl [3 ]
Murk, Axel [3 ]
Walker, David K. [1 ]
Wylde, Richard J. [4 ]
机构
[1] NIST, RF Technol Div, Boulder, CO 80305 USA
[2] Univ Colorado, Dept Aerosp Engn & Sci, Boulder, CO 80309 USA
[3] Univ Bern, Inst Appl Phys, CH-3012 Bern, Switzerland
[4] Thomas Keating Ltd, Billinghurst RH14 9SH, England
来源
基金
瑞士国家科学基金会;
关键词
Blackbody; brightness-temperature standard; calibration source; calibration target; cold load; hot load; microwave absorber; permeability; permittivity; radiometer calibration; PERMITTIVITY; STANDARD;
D O I
10.1109/TGRS.2017.2694319
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
A conical cavity has been designed and fabricated for use as a broadband passive microwave calibration source, or blackbody, at the National Institute of Standards and Technology. The blackbody will be used as a national primary standard for brightness temperature and will allow for the prelaunch calibration of spaceborne radiometers and calibration of ground-based systems to provide traceability among radiometric data. The conical geometry provides performance independent of polarization, minimizing reflections, and standing waves, thus having a high microwave emissivity. The conical blackbody has advantages over typical pyramidal array geometries, including reduced temperature gradients and excellent broadband electromagnetic performance over more than a frequency decade. The blackbody is designed for use between 18 and 230 GHz, at temperatures between 80 and 350 K, and is vacuum compatible. To approximate theoretical blackbody behavior, the design maximizes emissivity and thus minimizes reflectivity. A newly developed microwave absorber is demonstrated that uses cryogenically compatible, thermally conductive two-part epoxy with magnetic carbonyl iron (CBI) powder loading. We measured the complex permittivity and permeability properties for different CBI-loading percentages; the conical absorber is then designed and optimized with geometric optics and finite-element modeling, and finally, the reflectivity of the resulting fabricated structure is measured. We demonstrated normal incidence reflectivity considerably below -40 dB at all relevant remote sensing frequencies.
引用
收藏
页码:4586 / 4596
页数:11
相关论文
共 50 条
  • [1] The optimization design for microwave wide band blackbody calibration target
    Feng, Nian
    Wei, Wang
    2008 INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY PROCEEDINGS, VOLS 1-4, 2008, : 1695 - 1698
  • [2] G-band Reflectivity Results of a Conical Blackbody for Radiometer Calibration
    Houtz, Derek A.
    Gu, Dazhen
    2017 90TH ARFTG MICROWAVE MEASUREMENT SYMPOSIUM (ARFTG), 2017,
  • [3] MICROWAVE RADIOMETER BLACKBODY CALIBRATION STANDARD FOR USE AT MILLIMETER WAVELENGTHS
    GOLDSMITH, PF
    KOT, RA
    IWASAKI, RS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1979, 50 (09): : 1120 - 1122
  • [4] Design and RF performance analysis of microwave radiometer calibration targets
    Addamo, G.
    Peverini, O. A.
    Virone, G.
    Bosisio, A. V.
    Tascone, R.
    Valenziano, L.
    Di Cintio, A.
    Grilli, M.
    2018 IEEE 15TH SPECIALIST MEETING ON MICROWAVE RADIOMETRY AND REMOTE SENSING OF THE ENVIRONMENT (MICRORAD), 2018, : 151 - 153
  • [5] A FINITE ELEMENT THERMAL SIMULATION OF A MICROWAVE BLACKBODY CALIBRATION TARGET
    Houtz, Derek A.
    Walker, David K.
    2013 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2013, : 394 - 397
  • [6] Research of optimizing the microwave wide band blackbody calibration target
    Nian Feng
    Yang Yujie
    Wang Wei
    JOURNAL OF SYSTEMS ENGINEERING AND ELECTRONICS, 2009, 20 (01) : 6 - 12
  • [7] Research of optimizing the microwave wide band blackbody calibration target
    Nian Feng1
    2. Beijing Inst. of Radio Metrology & Measurement
    JournalofSystemsEngineeringandElectronics, 2009, 20 (01) : 6 - 12
  • [8] Jason Microwave Radiometer Performance and On-Orbit Calibration
    Brown, Shannon
    Ruf, Chris
    Keihm, Steve
    Kitiyakara, Ami
    MARINE GEODESY, 2004, 27 (1-2) : 199 - 220
  • [9] A Compact Passive Microwave Calibration Target for Full-polarized Radiometer
    Wang, Zhenzhan
    Liu, Jingyi
    Li, Bin
    Lu, Hao
    Li, Jiaoyang
    2017 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM - FALL (PIERS - FALL), 2017, : 2977 - 2980
  • [10] CALIBRATION OF A MICROWAVE RADIOMETER SYSTEM
    CHEKRYZHOV, YA