Assessing the pattern of femoral head penetration after total hip arthroplasty

被引:15
作者
Hopper, RH [1 ]
Young, AM [1 ]
Engh, CA [1 ]
McAuley, JP [1 ]
机构
[1] Anderson Orthopaed Res Inst, Alexandria, VA 22306 USA
关键词
hip; arthroplasty; polyethylene; wear; outcome;
D O I
10.1016/j.arth.2004.06.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We evaluated temporal changes in wear rates among 205 primary cementless total hip arthroplasties that had minimum 10-year follow-up and at least 6 follow-up x-rays. Using the pelvic anteroposterior x-rays from each hip, two-dimensional head penetration was measured and wear rates were calculated using several techniques. The average wear rate for the study population did not demonstrate evidence of accelerated wear at 10- to 18-year follow-up. As an increasing number of follow-up x-rays were included in the least-squares linear regression used to calculate the wear rate, the 95% confidence interval associated with the wear rate for an individual hip tended to progressively decrease. These results indicate that a constant wear rate is a reasonable assumption for modeling clinical wear data. Although we cannot quantify the effects of polyethylene oxidation, femoral bead roughening, debris accumulation, or activity level changes, the combination of these factors is not leading to clinically perceptible accelerated wear at intermediate to long-term follow-up in this heterogeneous population of cups representing our institutional experience. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:22 / 29
页数:8
相关论文
共 16 条
[1]  
Bono J V, 1994, J Arthroplasty, V9, P119, DOI 10.1016/0883-5403(94)90059-0
[2]  
Collier JP, 1996, CLIN ORTHOP RELAT R, P76
[3]  
Currier BH, 1997, CLIN ORTHOP RELAT R, P111
[4]   Validation of planar and tomographic radionuclide ventriculography by a dynamic ventricular phantom [J].
De Bondt, P ;
Vandenberghe, S ;
De Mey, S ;
Segers, P ;
De Winter, O ;
De Sutter, J ;
Van de Wiele, C ;
Verdonck, P ;
Dierckx, RA .
NUCLEAR MEDICINE COMMUNICATIONS, 2003, 24 (07) :771-777
[5]  
DEVANE PA, 1995, CLIN ORTHOP RELAT R, P303
[6]   Variation in the wear rate during the life of a total hip arthroplasty - A simulator and retrieval study [J].
Elfick, APD ;
Smith, SL ;
Unsworth, A .
JOURNAL OF ARTHROPLASTY, 2000, 15 (07) :901-908
[7]  
Engh CA, 2001, CLIN ORTHOP RELAT R, P137
[8]  
Fisher J, 1995, Proc Inst Mech Eng H, V209, P263, DOI 10.1243/PIME_PROC_1995_209_353_02
[9]   Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty [J].
Hui, AJ ;
McCalden, FW ;
Martell, JM ;
MacDonald, SJ ;
Bourne, RB ;
Rorabeck, CH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (03) :505-511
[10]   Determination of polyethylene wear in total hip replacements with use of digital radiographs [J].
Martell, JM ;
Berdia, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (11) :1635-1641