The effects of different repair methods for a posterior root tear of the lateral meniscus on the biomechanics of the knee: a finite element analysis

被引:20
作者
Wang, Jian-Yu [1 ,2 ]
Qi, Yan-Song [1 ]
Bao, Hu-Ri-Cha [1 ]
Xu, Yong-Sheng [1 ]
Wei, Bao-Gang [1 ]
Wang, Yong-Xiang [1 ]
Ma, Bing-Xian [1 ]
Zhou, Hui-Wen [1 ]
Lv, Fei [1 ]
机构
[1] Inner Mongolia Peoples Hosp, Dept Orthoped, 20 Zhao Wu Da St, Hohhot 010017, Inner Mongolia, Peoples R China
[2] Inner Mongolia Med Univ, Grad Sch, Hohhot, Inner Mongolia, Peoples R China
基金
中国国家自然科学基金;
关键词
Finite element analysis; Knee joint; Posterior root tear of lateral meniscus; Biomechanics; CONTACT AREA;
D O I
10.1186/s13018-021-02435-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To explore the impact of different repair methods for a lateral meniscus posterior root tear on the biomechanics of the knee joint using finite element analysis. Methods Finite element models of a healthy knee were established on the basis of MRI data from a volunteer using Mimics software, and the validity of the models was tested. The changes in the contact mechanics and kinematics of these finite element models under different repair approaches were then analyzed and compared. Results The normal meniscus had the maximum joint contact area, the minimum contact pressure, and the minimum contact stress. When total meniscectomy of the lateral meniscus was performed, the lateral compartment had the minimum joint contact area, the maximum contact pressure and the maximum contact stress. When complete avulsions of the posterior root of the lateral meniscus occurred, the maximum values of contact pressure and contact stress were between those of an intact meniscus and those of a meniscus treated with total meniscectomy. Lateral meniscal root attachment reconstruction by the single-stitch and double-stitch techniques resulted in a significant decrease in joint contact pressure and contact stress, leading to values comparable to those of a normal knee joint, and the double-stitch technique performed better than the single-stitch technique. Conclusions Repair surgery for lateral meniscal posterior root avulsions can effectively restore the contact mechanics and kinematics of the knee joint, and the double-stitch technique can result in better clinical outcomes than the single-stitch technique.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Effects of radial tears and partial meniscectomy of lateral meniscus on the knee joint mechanics during the stance phase of the gait cycleA 3D finite element study
    Mononen, Mika E.
    Jurvelin, Jukka S.
    Korhonen, Rami K.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (08) : 1208 - 1217
  • [22] The effects of different plate fixation methods in the zygomaticomaxillary complex: A finite element analysis
    Fallahi, Hamid Reza
    Keyhan, Seied Omid
    Forooghi, Iman
    Mahoutchi, Donya Sadat
    Abdollahi, Mohammad Reza
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY MEDICINE AND PATHOLOGY, 2020, 32 (02) : 93 - 100
  • [23] Predicting meniscal tear stability across knee-joint flexion using finite-element analysis
    Kedgley, Angela E.
    Saw, Teng-Hui
    Segal, Neil A.
    Hansen, Ulrich N.
    Bull, Anthony M. J.
    Masouros, Spyros D.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (01) : 206 - 214
  • [24] Biomechanical characteristics of 2 different posterior fixation methods of bilateral pedicle screws: A finite element analysis
    Ji, Yulei
    Zhang, Qiaolin
    Song, Yang
    Hu, Qiuli
    Fekete, Gusztav
    Baker, Julien S.
    Gu, Yaodong
    MEDICINE, 2022, 101 (36) : E30419
  • [25] Stress changes of lateral collateral ligament at different knee flexion with or without displaced movements: a 3-dimensional finite element analysis
    Zhong Yan-lin
    Wang You
    Wang Hai-peng
    Rong Ke
    Xie Le
    CHINESE JOURNAL OF TRAUMATOLOGY, 2011, 14 (02) : 79 - 83
  • [26] Predicting meniscal tear stability across knee-joint flexion using finite-element analysis
    Angela E. Kedgley
    Teng-Hui Saw
    Neil A. Segal
    Ulrich N. Hansen
    Anthony M. J. Bull
    Spyros D. Masouros
    Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 206 - 214
  • [27] Effect of degenerative and radial tears of the meniscus and resultant meniscectomy on the knee joint: a finite element analysis
    Zhang, Kaijia
    Li, Lan
    Yang, Longfei
    Shi, Jianping
    Zhu, Liya
    Liang, Huixin
    Wang, Xingsong
    Yang, Xianfeng
    Jiang, Qing
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2019, 18 : 20 - 31
  • [28] Biomechanical comparison of four different posterior malleolus fixation techniques: A finite element analysis
    Mansur, Henrique
    Lucas, Phelipe Pinheiro Alves
    Vitorino, Ricardo Carvalho
    Barin, Fabricio Reichert
    Freitas, Anderson
    Battaglion, Leonardo Rigobello
    Ramos, Lucas Sacramento
    FOOT AND ANKLE SURGERY, 2022, 28 (05) : 570 - 577
  • [29] Impact of Tibial Component Coronal Alignment on Knee Joint Biomechanics Following Fixed-bearing Unicompartmental Knee Arthroplasty: A Finite Element Analysis
    Nie, Yong
    Yu, Qiang
    Shen, Bin
    ORTHOPAEDIC SURGERY, 2021, 13 (04) : 1423 - 1429
  • [30] Biomechanical evaluation of different suture materials for arthroscopic transtibial pull-out repair of posterior meniscus root tears
    Feucht, Matthias J.
    Grande, Eduardo
    Brunhuber, Johannes
    Rosenstiel, Nikolaus
    Burgkart, Rainer
    Imhoff, Andreas B.
    Braun, Sepp
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (01) : 132 - 139