IMPROD biparametric MRI in men with a clinical suspicion of prostate cancer (IMPROD Trial): Sensitivity for prostate cancer detection in correlation with whole-mount prostatectomy sections and implications for focal therapy

被引:17
作者
Merisaari, Harri [1 ,2 ]
Jambor, Ivan [1 ,3 ]
Ettala, Otto [4 ,5 ]
Bostrom, Peter J. [4 ,5 ]
Perez, Ileana Montoya [1 ,2 ]
Verho, Janne [1 ,6 ]
Kiviniemi, Aida [1 ,6 ]
Syvanen, Kari [4 ,5 ]
Kahkonen, Esa [4 ,5 ]
Eklund, Lauri [7 ,8 ]
Pahikkala, Tapio [2 ]
Vainio, Paula [7 ,8 ]
Saunavaara, Jani [1 ,6 ]
Aronen, Hannu J. [1 ,6 ]
Taimen, Pekka [7 ,8 ]
机构
[1] Univ Turku, Dept Diagnost Radiol, Kiinamyllynkatu 4-8,POB 52, FI-20521 Turku, Finland
[2] Univ Turku, Dept Future Technol, Turku, Finland
[3] Icahn Sch Med Mt Sinai, Dept Radiol, New York, NY 10029 USA
[4] Univ Turku, Dept Urol, Turku, Finland
[5] Turku Univ Hosp, Turku, Finland
[6] Turku Univ Hosp, Med Imaging Ctr Southwest Finland, Turku, Finland
[7] Univ Turku, Inst Biomed, Turku, Finland
[8] Turku Univ Hosp, Dept Pathol, Turku, Finland
关键词
biparametric MRI; IMPROD trial; diffusion weighted imaging; prostate cancer; PSA; #openSOURCEtrial; RESONANCE-IMAGING UNDERESTIMATION; PATIENT-SPECIFIC MOLDS; TARGETED BIOPSY; GEOMETRY USE; RE; PATTERNS; IMAGES;
D O I
10.1002/jmri.26727
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Prostate MRI is increasingly being used in men with a clinical suspicion of prostate cancer (PCa). However, development and validation of methods for focal therapy planning are still lagging. Purpose To evaluate the diagnostic accuracy on lesion, region-of-interest (ROI), and voxel level of IMPROD biparametric prostate MRI (bpMRI) for PCa detection in men with a clinical suspicion of PCa who subsequently underwent radical prostatectomy. Study Type Prospective single-institution clinical trial (NCT01864135). Population Sixty-four men who underwent radical prostatectomy after IMPROD bpMRI performed in prebiopsy settings. Field Strength/Sequence IMPROD bpMRI consisted of T-2-weighted imaging (T(2)w) and three separate diffusion-weighted imaging acquisitions with an average acquisition time of 15 minutes. Assessment The diagnostic accuracy of prospectively reported manual cancer delineations and regions increased with 3D dilation were evaluated on the voxel level (volume of 1.17 mm(3), 1 mm(3), 125 mm(3)) as well as the 36 ROI level. Only PCa lesions with a diameter >= 5 mm or any Gleason Grade 4 were analyzed. All data and protocols are freely available at: Statistical Tests Sensitivity, specificity, accuracy. Results In total, 99 PCa lesions were identified. Forty (40%, 40/99) had a Gleason score (GS) of >3 + 4. Twenty-eight PCa lesions (28%, 28/99) were missed by IMPROD bpMRI, three (7.5%, 3/40) with GS >3 + 4. 3D dilation of manual cancer delineations in all directions by ~10-12 mm (corresponding to the Hausdorff distance) was needed to achieve sensitivity approaching 100% on a voxel level. Data Conclusion IMPROD bpMRI had a high sensitivity on lesion level for PCa with GS >3 + 4. Increasing 3D lesion delineations by ~10-12 mm (corresponding to the Hausdorff distance) was needed to achieve high sensitivity on the voxel level. Such information may help in planning ablation therapies. Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:1641-1650.
引用
收藏
页码:1641 / 1650
页数:10
相关论文
共 31 条
[1]   Diagnostic accuracy of multi-parametric MRI and TRUS biopsy in prostate cancer (PROMIS): a paired validating confirmatory study [J].
Ahmed, Hashim U. ;
Bosaily, Ahmed El-Shater ;
Brown, Louise C. ;
Gabe, Rhian ;
Kaplan, Richard ;
Parmar, Mahesh K. ;
Collaco-Moraes, Yolanda ;
Ward, Katie ;
Hindley, Richard G. ;
Freeman, Alex ;
Kirkham, Alex P. ;
Oldroyd, Robert ;
Parker, Chris ;
Emberton, Mark .
LANCET, 2017, 389 (10071) :815-822
[2]   Transatlantic Consensus Group on active surveillance and focal therapy for prostate cancer [J].
Ahmed, Hashim U. ;
Akin, Oguz ;
Coleman, Jonathan A. ;
Crane, Sarah ;
Emberton, Mark ;
Goldenberg, Larry ;
Hricak, Hedvig ;
Kattan, Mike W. ;
Kurhanewicz, John ;
Moore, Caroline M. ;
Parker, Chris ;
Polascik, Thomas J. ;
Scardino, Peter ;
van As, Nicholas ;
Villers, Arnauld .
BJU INTERNATIONAL, 2012, 109 (11) :1636-1647
[3]   Mesh: Measuring errors between surfaces using the Hausdorff distance [J].
Aspert, N ;
Santa-Cruz, D ;
Ebrahimi, T .
IEEE INTERNATIONAL CONFERENCE ON MULTIMEDIA AND EXPO, VOL I AND II, PROCEEDINGS, 2002, :705-708
[4]   Reply to Letter to the Editor re: ESUR prostate MR guidelines [J].
Barentsz, Jelle ;
Villers, Arnauld ;
Schouten, Martijn .
EUROPEAN RADIOLOGY, 2013, 23 (08) :2322-2323
[5]  
Boesen L, 2018, ASSESSMENT DIAGNOSTI, V1, P1
[6]  
Boesen L, 2018, EUR UROL ONC, DOI [10.1016/j.euo.2018.09.001, DOI 10.1016/J.EU0.2018.09.001]
[7]   Assessment of the Diagnostic Accuracy of Biparametric Magnetic Resonance Imaging for Prostate Cancer in Biopsy-Naive Men The Biparametric MRI for Detection of Prostate Cancer (BIDOC) Study [J].
Boesen, Lars ;
Norgaard, Nis ;
Logager, Vibeke ;
Balslev, Ingegerd ;
Bisbjerg, Rasmus ;
Thestrup, Karen-Cecilie ;
Winther, Mads D. ;
Jakobsen, Henrik ;
Thomsen, Henrik S. .
JAMA NETWORK OPEN, 2018, 1 (02)
[8]   Apparatus for histological Validation of In Vivo and Ex Vivo Magnetic Resonance Imaging of the human Prostate [J].
Bourne, Roger M. ;
Bailey, Colleen ;
Johnston, Edward William ;
Pye, Hayley ;
Heavey, Susan ;
Whitaker, Hayley ;
Siow, Bernard ;
Freeman, Alex ;
Shaw, Greg L. ;
Sridhar, Ashwin ;
Mertzanidou, Thomy ;
Hawkes, David J. ;
Alexander, Daniel C. ;
Punwani, Shonit ;
Panagiotaki, Eleftheria .
FRONTIERS IN ONCOLOGY, 2017, 7
[9]   STARD 2015 guidelines for reporting diagnostic accuracy studies: explanation and elaboration [J].
Cohen, Jeremie F. ;
Korevaar, Daniel A. ;
Altman, Douglas G. ;
Bruns, David E. ;
Gatsonis, Constantine A. ;
Hooft, Lotty ;
Irwig, Les ;
Levine, Deborah ;
Reitsma, Johannes B. ;
de Vet, Henrica C. W. ;
Bossuyt, Patrick M. M. .
BMJ OPEN, 2016, 6 (11)
[10]   Multiparametric magnetic resonance imaging for the detection and localization of prostate cancer: combination of T2-weighted, dynamic contrast-enhanced and diffusion-weighted imaging [J].
Delongchamps, Nicolas Barry ;
Rouanne, Mathieu ;
Flam, Thierry ;
Beuvon, Frederic ;
Liberatore, Mathieu ;
Zerbib, Marc ;
Cornud, Francois .
BJU INTERNATIONAL, 2011, 107 (09) :1411-1418